Cold Start returns the unit to its default settings. Only perform this procedure when  
advised to do so by your dealer or a Munters technician.  
To perform a Cold Start:  
1. Disconnect power.  
2. Apply power while pressing Select, Up Arrow, and Down Arrow.  
3. When Cold Start Screen appears, press Select.  
4.3 Software Version  
After applying power, RDT-5:  
Loads the temperature and growth day settings  
Displays the software version on the screen for a few seconds  
Figure 2: Software Version  
NOTE If the RDT-5 cannot load the settings, it displays ----- in place of the software  
version. These lines should disappear within a short time. If the lines remain in  
place, reapply power. If they still remain in place, contact Technical Support.  
NOTE RDT-5 retains all settings in the event of any power cut.  
4.4 RDT-5 Configuration  
The following sections explain how to configure the RDT-5.  
Quick Start  
Reading the Main Screen  
Displaying the Current Temperature  
Configuring the Basic Settings  
Configuring the Stage Activation Temperature  
Configuring the Temperature Curve  
UICK TART  
4.4.1 Q  
S
This section describes the basic setup steps. For more detailed information refer to the  
subsequent sections.  
1. Press Select quickly. The unit displays the current temperature.  
2. Press Down Arrow for three seconds. Set the general settings.  
3. Press Select for three seconds. The 3 digit display shows current stage activation  
temperature and “dif”. Use the arrow keys to modify the dif.  
© Munters AB, 2021  
10  
GeneralDetails
NameMunters RDT-5 Triple Phase Digital Thermostat User Manual
MakeMunters
LanguageEnglish
FiletypePDF (Download)
File size0.5 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...

Munters RDT-5 Triple Phase Digital Thermostat User Manual