RECEIVER WIRING DIAGRAM  
ROOM THERMOSTAT  
1
ENGLISH  
HEATING/COOLING UNIT  
2
3
DIGITAL ROOM THERMOSTAT  
4
5
generallife.com.tr  
BATTERY PLACEMENT  
MITRA 230S RF USER MANUAL  
6
AC  
NO COM  
(230V)  
1
2
Battery Indicator  
Heating Indicator  
- If the Heating Indicator is blinking, the heating unit is working.  
- If the Heating Indicator is steady, the heating unit is not working.  
Cooling Indicator  
- If the Cooling Indicator is blinking, the cooling unit is working.  
- If the Cooling Indicator is steady, the cooling unit is not working.  
Room Temperature  
Set Temperature  
ON/OFF and Temperature Setting Button  
GENERAL SPECIFICATIONS  
Warning!  
Operations within the heating / cooling unit or the electrical installation  
must be carriedout byprofessionally qualified persons.  
MITRA 230S RF is a wireless room thermostat. The user can adjust  
the room temperature with the required temperature and get more  
comfortable and economic heating/cooling.  
3
PAIRING THE ROOM THERMOSTAT AND THE RECEIVER  
Primarily press the sync button of receiver for 2 seconds and see blinking  
green light of receiver.  
4
5
6
PreciseTemperatureMeasurement  
Heating calibration  
ON/OFFControl  
While yourdeviceis turned off, pressand hold thebutton for 3 seconds.  
WirelessConnection  
HysteresisSettings  
As shown in the picture above, press the screwdriverforward from the space  
shown, bend the tabs and separate the front cover. Insert 2 new AAA alkaline  
batteries in the battery housing with the correct battery direction. Replace  
both batteries at the same time. Then align the front part of your Room  
Thermostatto the backand squeezeittowards theback.  
Press thebutton until the “  
” menu appears.  
Heating/Cooling Modes  
RECEIVER  
Then turn up thebutton to right or leftway.  
1-Manual Operation Button:  
Deactivates the Receiver and allows you  
If the pairing is successful, the green flashing LED on the receiver will be  
constant.  
1
2
3
MITRA 230S RF AND EQUIPMENTS  
to use heating/cooling unit manually.  
2-Pairing Button:  
Receiverand Room Thermostathavebeen paired to each other.  
Low Battery Warning: When the “  
” icon appears on the screen, it means  
Holder  
Alkaline  
Battery  
MITRA 230S RF  
Room Thermostat  
“low battery warning”. It is recommended to replace the batteries when this  
warning appears.  
Pairs the Receiver and the Room  
ROOM THERMOSTATTEMPERATURE CALIBRATION  
Temperature sensors which are used in Room Thermostats are highly  
sensitive. You mayneed to calibrate yourRoom Thermostat if youwould like  
to get the same temperature values with other thermometers in your living  
space.  
Thermostat.  
Warning: When the product is not used for a long period (more than 15 days),  
remove the batteries. Otherwise, malfunctions that may occur would be out of  
warranty.  
3-Receiver LED Light  
4-Receiver Power Cable Input  
5-Heating/Cooling Unit Connection  
Cable Input  
Please throwyour dead batteries into thewastebin for batteries.  
While yourdeviceis turned off, pressand hold thebutton for 3 seconds.  
Press the button until the “ ” menu appers. In order to see the desired  
RECEIVER PLACEMENT  
temperature, set the temperature difference by turning the button to right  
or left. This valuecan be arranged between-8oC" and “+8oC".  
To save the settings and exit, press the "On/Off" button until the device  
turns off.  
4
5
The important things to note for the Receiver  
placement is avoiding physical contact between the  
Receiver and heating/cooling unit, and protecting it  
against materialssuch asliquid, dust etc.  
Dowels and  
Screws  
Receiver  
RECEIVER LED DESCRIPTIONS  
Constant Red  
Blinking Green  
Constant Green  
Receiver has power but Receiver and Room  
Note:Recommended tempreturecalibration is “0.0oC”.  
Thermostat are not paired.  
Waiting for pairing signal from the  
Room Thermostat.  
ROOM THERMOSTAT HEATING / COOLING MODES  
Your Room Thermostat has heating and cooling modes. In order to switch  
easilybetweenheating and cooling modes:  
Receiver and Room Thermostat are paired.  
Heating/cooling unit is not operating.  
Operate the heating/cooling unit signal has  
reached to the Receiver.  
The devices should be placed in order to minimize the damage to the  
receivedand transmittedsignals bypayingattentiontothefollowingpoints;  
While yourdeviceis turned off, press and hold the button for 3 seconds.  
The devicesshould not be mounted on metalsurfaces.  
The devices should not be installed close to electrical cables and  
electronic equipment such ascomputers and televisionunits.  
The devices should not be installed near large metal structures or other  
building materials using fine metal meshes such as special glass or  
special concrete.  
3 Short Orange  
Blinking  
Pressthebutton until the“  
You can switch between “  
” menu appears.  
” (heating) and “  
” (cooling) modes by  
Constant Orange  
Heating/cooling unit is operating.  
turning thebutton to right or leftin the“  
” menu.  
TECHNICAL DATA  
To savethesettings and exit, press thebutton until thedeviceturns off.  
The settings you have made have been saved. Once you turned on your  
device, itwill operatewith thechanged settings.  
3 Short Green  
Blinking  
Shut the heating/cooling unit down signal has  
reached to the Receiver.  
Room Thermostat  
Distance between the Room Thermostat and the Receiver should not  
exceed 20metersor 2 floors.  
Blinking Orange  
Heating/Cooling unit operates in manual mode.  
Dimensions  
85mm / 125mm / 24mm  
3V DC (2 x AAA alkaline battery)  
0.1oC  
ROOM THERMOSTAT HYSTERESIS POSITIVE MENU  
Operating Current  
Temperature Measurement  
Accuracy  
Receiver must be installed at least 50 cm away from the heating/cooling  
unit.  
Hysteresis positive factory setting of your room thermostat is 0.5°C. This  
value may be adjusted between “0.1°C” and “2.0°C”. While hysteresis  
positive value is 0.5°C, if the room temperature goes above 0.5°C of set  
Blinking Red  
Receiver did not get any signal from the Room  
Thermostat for 22 minutes or longer.  
Heating/cooling unit has shut down.  
(-2.0oC) – (+2.0oC)  
(5oC) – (30oC)  
RECEIVER SETUP  
Operating Sensitivity  
Operating Temperature Range  
Battery Life  
temperature, your room thermostat will send  
heating/cooling unit.  
a
signal to your  
First, shut down your heating/cooling unit and your heating/cooling unit's  
power sourcewith allelectricalcurrent(fuse, socketetc.)  
As shown in the connection diagram, connect one end of the  
heating/cooling unit connection cable to the COM and the other to the NO  
input of the Receiver.  
ROOM THERMOSTAT PLACEMENT  
1 Years (2 x AAA)  
(-10oC) – (+50oC)  
(-20oC) – (+60oC)  
For instance, when you set your room thermostat to 22.0°C, if the room  
temperature goes above 22.5°C, on heating mode your heating unit will stop  
working; on cooling mode your cooling unit will start working. In order to  
change the hysteresispositivesetting:  
Room Thermostat needs to be placed in the room which is used most  
frequently. For instance; living room or lounge. Placing the Room  
Thermostat in a spot that have air circulation like entrance of a room  
or side of window should be avoided. Also anywhere close to  
heating/cooling units such as radiator, stove and spots which get  
direct sun lights would not be suitable. Room Thermostat needs to be  
located above the floor 150 cm height. Few trials may be made to find  
themostconvenientspot.  
Operating Temperature  
Storage Temperature  
Connect the other ends of the cable -which you connected to the Receiver  
to room thermostat connection terminal as shown in your  
heating/cooling unit's user manual.  
Pressthebutton for 3seconds whileyourdeviceis off.  
Pressthebutton until “  
Adjust the operating sensitivity by turning the button to the left or  
right in the hysteresispositivemenu.  
“ menu appears.  
Receiver  
You must first connect the Receiver power cable to the Receiver and then  
to the fuse to which theheating/cooling unit is connected.  
After completing the cable connection process, firstly turn on your fuse  
and then yourheating/cooling unit.  
Dimensions  
90mm / 90mm / 25mm  
230V AC  
Pressthebutton until deviceturns off to savethechanges and exit.  
Changes have been saved. Your room thermostat will be working  
withsetoperating sensitivitywhen youopen yourdevice.  
Operation Current  
Relay NO Switching Current  
min. 20 cm  
7A (240VAC – Resistive load)  
10A (120VAC – Resistive load)  
(-20oC) – (+60oC)  
By pressing the Receiver's manual usage button for 2 seconds, youshould  
see the Orange Light blinking on the Receiver. In this way, after making  
sure that the heating/cooling unit is operating, press the same button  
again for 2 seconds and seethattheOrange LEDturns off.  
Set up the Room Thermostat to pair the Receiver with the Room  
Thermostat.  
Storage Temperature  
2
1
3
4
GeneralDetails
NameGENERAL LIFE Mitra 230S RF Wireless Room Thermostat User Manual
MakeGENERAL LIFE
LanguageEnglish
FiletypePDF (Download)
File size2.22 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
GENERAL LIFE HT330S RF Room Thermostat User Manual
GENERAL LIFE HT330S RF Room Thermostat User Manual
GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual
GENERAL LIFE HT250 RF Digital Room Thermostat User Manual
GENERAL LIFE HT250 RF Digital Room Thermostat User Manual
GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual
GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual
GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual
GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual
GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual
GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual
GENERAL LIFE HT220S RF Digital Room Thermostat User Manual
GENERAL LIFE HT220S RF Digital Room Thermostat User Manual
GENERAL LIFE 270S RF Room Thermostat User Manual
GENERAL LIFE 270S RF Room Thermostat User Manual
GENERAL LIFE 270 Wireless Room Thermostat User Manual
GENERAL LIFE 270 Wireless Room Thermostat User Manual

GENERAL LIFE Mitra 230S RF Wireless Room Thermostat User Manual
Get the free PDF manual for the GENERAL LIFE Mitra 230S RF Wireless Room Thermostat User Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

GENERAL LIFE Mitra 230S RF Wireless Room Thermostat User Manual Overview

Summary of Contents

  • Page 1: Receiver wiring diagram Room thermostat Heating/cooling unit Digital room thermostat Battery placement Mitra 230S RF user manual Heating indicator: If blinking, the heating unit is working; if steady, it is not. Cooling indicator: If blinking, the cooling unit is working; if steady, it is not. Mitra 230S RF is a wireless room thermostat that allows users to adjust room temperature for comfort and efficiency. Operations within the heating/cooling unit must be carried out by professionally qualified persons. Pairing the room thermostat and the receiver involves pressing the sync button for 2 seconds. Receiver placement should avoid physical contact with heating/cooling units and protect against liquids and dust. Room thermostat needs to be placed in frequently used rooms, avoiding areas with direct sunlight or near heating/cooling units. Receiver must be installed at least 50 cm away from the heating/cooling unit. Hysteresis positive factory setting of the room thermostat is 0.5°C, adjustable between 0.1°C and 2.0°C. Low battery warning appears when the battery is low, indicating a need for replacement. To save settings, press the button until the device turns off.
  • Page 2: Warranty conditions state that the warranty period starts from the invoice date and covers manufacturing defects for 5 years. The room thermostat sends a status signal to the receiver every 10 minutes to ensure synchronous operation. If the connection is broken for 22 minutes, the heating/cooling operation stops for safety reasons. The hysteresis negative factory setting is -0.5°C, adjustable between -0.1°C and -2.0°C. Devices are delivered in working condition, and on-site commissioning incurs a service fee. Repairs covered by the warranty must be sent to the company factory, with transportation costs borne by the customer for on-site services. Maintenance is performed by the company, with travel expenses covered by the customer. Malfunctions caused by customer misuse are not covered by the warranty. The warranty document must be retained by the customer, and a replacement will not be issued if lost. The manufacturer reserves the right to change product specifications and user manuals.