4. Press Up Arrow for three seconds. The three digits display F.d and 1 (Stage 1). Use
the arrow keys to set the day.
EADING THE AIN CREEN
4.4.2 R
M
S
The RDT-5 Main Screen displays the:
current stage
•
•
target temperature
In Figure 2, the current stage is Stage 5 and the target temperature is 20.6° C.
To navigate between stages:
Press the Stage key. The Stage display and corresponding target temperature
•
changes.
ISPLAYING THE URRENT EMPERATURE
4.4.3 D
C
T
To display the current temperature:
1. Press Select quickly.
The 3 digit display shows current temperature and “-t”.
2. Press Stage to navigate between stages.
NOTE After 10 seconds of inactivity on the keyboard, the display returns to the Main
Screen.
ONFIGURING THE ASIC ETTINGS
4.4.4 C
B
S
There are several parameter settings which must be set before configuring target
temperatures and temperature curves. These parameters are not displayed.
Mode
Centigrade/Fahrenheit
Clock time (hour/minute)
•
•
•
•
Current growth day
The RDT-5 can work as in standalone mode (PrE) or in conjunction with the Platinum
controller (Aut). In standalone mode, the RDT-5 sets the target temperature curve (and
the differential related to it). When working with the Platinum, the RDT-5 sets the
differential related to the Platinum target temperature.
To set the basic settings:
1. Press Down Arrow for three seconds.
The 3 digit display shows PrE or Aut.
2. Use the arrow keys to select PrE.
3. Press Select.
Use the arrow key to select C or F.
4. Press Select.
The 3 digit display shows dAY and the current setting.
5. Use the arrow keys to set the current day.
Press Select.
6. The 3 digit display shows Hr and the current hour value.
Use the arrow keys to set the hour.