Munters RDT-5 Triple Phase Digital Thermostat User Manual
LATINUM
OMMUNICATION
– RDT-5 C
5.2.7 P
•
•
Platinum 5.10 and above support RS-485 communication with the RDT-5.
All Platinum versions support RS-232 communication with the RDT-5.
Figure 12: RDT-5 to Platinum RS-232 Communication
Figure 12 key
1
RDT-5 Unit
2
3
4
RDT-5 Communication Card RS-232 Direct
Platinum PP-232_485 Communication Card
Platinum Controller
NOTE: When using RS-232 cabling, place the RDT-5 within 10 meters of the controller.
CAUTION The RS-232 Communication Card comes prewired to the RDT-5 Alarm NO
and COM ports. When wiring the RDT-5 to a Digital Card (RDIC), leave this wiring in
place and connect RDIC wiring to the same ports.
WARNING! If your RDT-5 is equipped with a C-RNET-DIR Ver 1.0.0 communication card,
contact your dealer about an upgrade.