heatit Z-TRM6 DC Z Wave Electronic Thermostat Instruction Manual
PRODUCT INFO
39.1 Error messages in display
PRODUCT INFO Heatit Z-TRM6 DC 3A
Failed to include
FEATURES
• Z-Wave thermostat
• Internal room sensor
• Adjustable display
brightness
Internal error:
• External room sensor (wired) • Single pole switch
MCU and Z-Wave chip
communication failed
• Floor sensor
• Lock mode/child lock
• Temperature read out in
gateway
• Temperature limiter
• Boiler control
Z-Wave error
• Control of actuators
• 3 modes; Heat, Cool, Eco
• Hysteresis/PWM
• Weekly schedule in
gateway
• Manual power metering
• SmartStart
• Temperature calibration
• Open window detection
• Relay status icon
Internal sensor error
Floor sensor error
External sensor error
Overheat
• Firmware update (OTA)
• Supports encryption mode: S0, S2 Authenticated Class,
S2 Unauthenticated Class
The product must be used with a security-enabled Z-Wave
controller in order to fully utilize security/encryption.
TECHNICAL DATA
Protocol
Z-Wave, 868.4MHz
Z-Wave 800 chip
230VAC 50Hz
3A 24VDC
Chip
Rated voltage
Max load
Max actuators
Power consumption
3x24VDC actuators
<2W
39.2 General display messages
Ambient temperature 5°C to 40°C
Temperature range
Storage temperature
Hysteresis
5°C to 40°C
Childlock activated
Childlock disabled
-30°C to 70°C
0.3°C to 3.0°C (default 0.5°C)
10% to 85% RH
Humidity
Compatible with NTC-
sensor with values
6.8, 10, 12, 15, 22, 33, 47 or
100kΩ @ 25°C
Backlight on when
device in standby
Range RF
Min. 40 meter
Screw terminals
IP Code
Max. 2.5mm2 2Nm
IP21
Backlight off when
device in standby
Size (LxWxH)
84 x 84 x 45mm
Approvals
Z-Wave Plus v2, CE, Nemko
Open window detected
Settings stored
MAINTENANCE
The device is maintenance-free. Indoor use only.
DISPOSAL GUIDELINES
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection
facilities. Contact your local government for information regarding the collection systems
available. If electrical appliances are disposed of in landfills or dumps, hazardous substances
can leak into the groundwater and get into the food chain, damaging health and well-being.
We have designed this product in accordance with our strict quality requirements (ISO 9001) and
environmental requirements (ISO 14001). All electrical installations must be carried out by an authorized
electrical installer. The product must be installed in accordance with our installers manual and national
building codes. Any wrongful installation, misuse or damage to the product is not covered under warranty.
Heatit Controls AB · Läkarvägen 4, 454 31 BRASTAD, SWEDEN
Heatit Controls AB can not be held liable for any type of errors or omittances in our product information.
Product specifications may change without further notice.
| General | Details |
|---|---|
| Name | heatit Z-TRM6 DC Z Wave Electronic Thermostat Instruction Manual |
| Make | HEATIT |
| Language | English |
| Filetype | PDF (Download) |
| File size | 4.1 MB |

HEATIT Z-TRM3 Thermostat User Guide

Heatit Z-TEMP2 Thermostat Installation Guide

heatit Z-TRM3 WiFi Thermostat Instruction Manual

HEATIT Z-Temp3 is a Battery Operated Thermostat Instruction Manual

4512673 Heatit ZM Thermostat 16A User Guide

HEATIT Z-TRM6 Matt Z-Wave Thermostat User Guide

HEATIT 54 304 59 DIN Smart Thermostat Installation Guide

HEATIT 54 305 41 WiFi6 Thermostat Installation Guide

HEATIT Z-TEMP3 Thermostat User Guide

heatit ET-7AW Touchscreen Programmable Thermostat User Manual