heatit Z-TRM6 DC Z Wave Electronic Thermostat Instruction Manual

the Right button and then finally twice on the Center button.  
This will unlock the thermostat until it goes back to standby,  
requiring you to unlock it again.  
SHORT  
DESCRIPTION / COMMENT  
DESCRIPTION  
OF VALUE  
NAME  
OFF  
0
Protection State to 0x02 means that no operation is possible  
and the thermostat can only be unlocked by setting Parameter  
1 “Disable buttons” to 0, or by holding the Center and Right  
buttons for 30 seconds.  
Thermostat will not operate  
Operating  
Mode  
(MODE)  
1
2
3
Heating mode (Default)  
Cooling mode  
25  
26  
1
1
Set the thermostat mode.  
1
ECO mode  
Open window detection  
disabled. (Default)  
0
1
Open  
window  
detection  
Choose to enable or disable  
the Open windows detection.  
0
Open windows detection  
enabled.  
34.4 Thermostat Setpoint Command Class  
Thermostat Setpoint is implemented with 3 setpoints, Heating,  
Cooling and ECO. Supported setpoints are from 5°C - 40°C  
with 0.5°C increments.  
Uses power metering  
values. (Default)  
0
Allows the user to decide  
the power consumption of  
the connected load in 100W  
increments.  
1-99 = 100-9900 Watt  
27  
28  
29  
2
1
1
Size of load  
Allows the user to set the  
size of the load, used when  
connected to a contactor.  
1
99  
0
1
Inverted  
output  
Decides if the device output  
should be inverted.  
0
0
Inverted output  
Valves do not open  
34.5 Thermostat Mode Command Class  
It is possible to change the operating mode of the thermostat  
by sending a Thermostat Mode set command. The accessible  
operating modes are:  
0
Relay will turn on to open  
valves for the selected amount  
of time after 30 days of  
inactivity.  
periodically. (Default).  
1 to 30 minutes, amount  
of time relays should be  
turned on for after 30 days  
of relay inactivity.  
Valve  
inactivity  
exercise  
1
30  
0x00: OFF (Thermostat regulation and display are  
deactivated).  
34.COMMAND CLASSES  
Additional information regarding Command Classes and their  
functionality:  
0x01:  
Heating Mode (Thermostat regulation is active).  
0x02: Cooling Mode (Thermostat regulation is inverted).  
0x0B: ECO Mode (Thermostat regulation is active with a  
separate setpoint from Heating Mode).  
34.1 Basic Command Class  
A Basic command to the device will change the thermostat  
mode. Uses the following values:  
0x00 = OFF (0x00)  
34.6 Thermostat Operating State Command Class  
The thermostat reports the operating state of the interal relay  
using this Command Class.  
0xFF = HEAT (0x01)  
0x00 = Idle  
If the thermostat is in ECO or COOL mode, 0x00 will still  
change the mode to OFF. ECO or COOL cannot be enabled  
with a Basic Set command.  
0x01 = Heating (used for Heating and ECO mode)  
0x02 = Cooling  
34.7 Indicator Command Class  
34.2 Meter Command Class  
The device supports the Indicator Command Class. The  
indicator Command Class will flash the display.  
The device supports Meter Command Class Get, and the  
thermostat will only respond on supported electric meter  
scales: kWh (accumulated) and Watt (instant).  
34.8 Notification Command Class  
The product features security features that announce any  
action using the Notification Command Class.  
The following commands are implemented:  
The device will report when asked:  
Rate type:  
Import (0x01)  
Meter type:  
Electric meter (0x01)  
STATE  
EVEN/  
STAT  
STATE  
VARIABLE  
VARIABLE  
AFTER  
NOTIFICATION  
NAME  
NAME  
VALUE  
VALUE  
TYPE  
SCALE  
VALUE  
SIZE  
PRECISION REPORT HYSTERESIS  
Overheating  
detected  
3600s and on state  
change, not configurable  
Heat alarm  
0x04  
State  
Heat sensor status  
Idle  
0x02  
Electric  
kWh  
0x01  
4
1
3600s, state change  
and on change in  
LOAD parameter, not  
Electric  
W
0x01  
4
1
34.9 Binary Switch Command Class  
configurable  
Binary Switch commands are used to control external relays  
associated with group 2.  
Uses the following values:  
0x00 = OFF  
34.3 Protection Command Class  
Protection Command Class allows you to disable local control  
of the thermostat, this is separately from the Child Lock  
function.  
0xFF = ON  
This Command Class is based on the operating state of the  
thermostat (relay on or off).  
To enable the Protection Command Class, either set  
Parameter 1 “Disable buttons” to value 1, enabling Local  
Protection State 0x02, or send a Protection Set with Local  
Protection State 0x01 or 0x02.  
During Protection State 0x01, the device is protected by a  
button sequence and allows for no local operation until it is  
unlocked. To unlock the thermostat while in Protection state  
0x01, first press twice on the Left button, then press twice on  
GeneralDetails
Nameheatit Z-TRM6 DC Z Wave Electronic Thermostat Instruction Manual
MakeHEATIT
LanguageEnglish
FiletypePDF (Download)
File size4.1 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
HEATIT Z-TRM3 Thermostat User Guide
HEATIT Z-TRM3 Thermostat User Guide
Heatit Z-TEMP2 Thermostat Installation Guide
Heatit Z-TEMP2 Thermostat Installation Guide
heatit Z-TRM3 WiFi Thermostat Instruction Manual
heatit Z-TRM3 WiFi Thermostat Instruction Manual
HEATIT Z-Temp3 is a Battery Operated Thermostat Instruction Manual
HEATIT Z-Temp3 is a Battery Operated Thermostat Instruction Manual
4512673 Heatit ZM Thermostat 16A User Guide
4512673 Heatit ZM Thermostat 16A User Guide
HEATIT Z-TRM6 Matt Z-Wave Thermostat User Guide
HEATIT Z-TRM6 Matt Z-Wave Thermostat User Guide
HEATIT 54 304 59 DIN Smart Thermostat Installation Guide
HEATIT 54 304 59 DIN Smart Thermostat Installation Guide
HEATIT 54 305 41 WiFi6 Thermostat Installation Guide
HEATIT 54 305 41 WiFi6 Thermostat Installation Guide
HEATIT Z-TEMP3 Thermostat User Guide
HEATIT Z-TEMP3 Thermostat User Guide
heatit ET-7AW Touchscreen Programmable Thermostat User Manual
heatit ET-7AW Touchscreen Programmable Thermostat User Manual

heatit Z-TRM6 DC Z Wave Electronic Thermostat Instruction Manual