9. FIRST START  
When the receiver is plugged into the power socket it signals the relay operation mode. Flash  
of the green LED normally open mode (COM NO), flash of the red LED normally closed  
mode (COM NC).  
Each change of the thermostat status (switching the heating on/off) is implemented  
immediately, whereas the signalization confirming reception of the transmitter radio signal is  
repeated every 15 minutes.  
9.1. Radio signal strength  
Information on the strength of the radio signal is shown with the confirmation of transmitter  
signal reception. Reception of the radio signal is confirmed with the green signal. Three flashes  
of the LED stand for a very strong connection, two flashes good connection and one flash –  
sufficient connection.  
9.2. No radio communication  
If the communication between the thermostat and the receiver is interrupted (e.g. due to  
discharged batteries) and such a condition lasts for 60 minutes (no response from the  
receiver), the receiver will switch to the anti-frost mode. The heating device will be switched  
on for 20 minutes every 3 hours, to prevent extensive cooling of the rooms. At the time of re-  
establishing communication (replacement of batteries), the receiver switches the system off  
and automatically resumes operation.  
No radio communication is signaled with the green diode flashing fast.  
9.3. Continuous operation of the heating device (MAN)  
In the case of system damage, it is possible to switch the heating on manually. Move the  
switch on the RX receiver to the MAN position. Such status is signaled with red (in the heating  
mode) or blue (in the cooling mode) LED flashing fast. Additionally, the “RX MANUAL” message  
is displayed on the thermostat.  
9.4. The receiver signal chart  
Function  
Signal  
Pairing  
Blue  
Radio signal reception  
Green  
No signal  
Green flashing  
Switching on the heating device  
Manual override in the heating mode  
Switching on the air-conditioning device on  
Manual override in the air-conditioning mode  
Wi-Fi connection reset  
Red  
Red flashing  
Blue  
Blue flashing  
Alternately green & blue 3 times  
10. MAINTENANCE  
Do not use solvents and aggressive detergents to clean the thermostat, since they may  
damage the surface of the housing and the display. Clean the thermostat housing with a soft  
cloth.  
GeneralDetails
NameEUROSTER 4040 Smart Programmable Thermostat User Manual
MakeEUROSTER
LanguageEnglish
FiletypePDF (Download)
File size0.33 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
EUROSTER 2006TXRX Wireless Programmable Thermostat Installation Guide
EUROSTER 2006TXRX Wireless Programmable Thermostat Installation Guide
EUROSTER 2026TXRX Air Conditioning Thermostat Instruction Manual
EUROSTER 2026TXRX Air Conditioning Thermostat Instruction Manual

EUROSTER 4040 Smart Programmable Thermostat User Manual