By default, the maximum floor temperature is set to
35 °C.
Always use a floor sensor or a room + floor sensor
combination to control floor heating. Without a floor
sensor, the temperature control may be less accurate
and you risk overheating the floor.
Thermal
resistance flooring
[m²K/W]
Examples of Details
Approximate
setting for
25˚C floor
temperature
8 mm HDF
0,05
> 800 kg/m3
28 °C
31 °C
32 °C
based laminate
14 mm beech
parquet
650 -
800 kg/m3
0,10
0,13
22 mm solid
oak plank
> 800 kg/m3
Max. carpet
thickness
suitable for
floor heating
acc. to
EN 1307
< 0,17
0,18
34 °C
35 °C
22 mm solid fir
planks
450 -
650 kg/m3