Home > COMPUTHERM > COMPUTHERM E800RF Multizone Wi-Fi Thermostat Instruction Manual
×
- 1. Computherm E800rf (Multizone Wi-fi Thermostat → Operating Instructions)
- 2.
- 3. A General Description Of The Thermostat (Important Warnings And Safety Recommendations → Meaning Of The Led Lights On Receiver Unit → Information Appearing On The Display Of The Thermostat → Functions Accessible In The Phone Application → Connection And Installation Of The Thermostat And The Receiver Unit → Setting Up The Internet Control)
- 4. 10.2. Disabling Further Connections Of The Thermostat Assigned To The
- 5. 1. General Description Of The Thermostat
- 6. An Example Of Dividing The Heating System Into Zones Is Shown In The Figure Below:
- 7. Chapter 7 For Installation, Connection And Synchronization Of The Receiver With The Thermostats. (Chapter 11. → The Portability Of The Thermostat Offers The Following Advantages: → A Computherm E800rf Thermostats Can Be Used To Control:)
- 8. Reliably
- 9. Led Marked: Pump (Blue Led, Marked: Boiler)
- 10. 4. Information Appearing On The Display Of The Thermostat
- 11. Functions Accessible In The Phone Application
- 12. Location Of The Thermostat And The Receiver Unit (Installation Recommendations → Receiver Unit Location → Electric Shock Prevention → Important Warning)
- 13. Connection And Installation Of The Thermostats And The Receiver Unit (Putting The Thermostat Into Operation)
- 14. Putting The Receiver Unit Into Operation (Connecting The Controlled Device(es) To The Receiver Unit → Attention!)
- 15. The Back Of The Receiver (Heating Unit (boiler) → Zone Valves → Connecting The Receiver Unit To The Mains)
- 16. Synchronization Of The Thermostat And The Receiver Unit
- 17. Attention! (The Thermostat Synchronizes With The Receiver Within 1 Minute After Performing The Synchronization Steps. → If The Value Displayed On The Thermostat Matches The Last Two Digits Of The Number On The Receiver, Press The Button Again. → The Thermostats Display Shows The Text On The Right And The Number On The Left.)
- 18. Setting Up The Internet Control (Installing The Application)
- 19. Connecting The Thermostat To A Wi-fi Network (Synchronization Steps)
- 20. Connecting The Thermostat To The Application (Controlling A Thermostat By Multiple Users)
- 21. Operation Of The Thermostat (Basic Settings → Renaming The Thermostat Assigned To The Application)
- 22. Disabling Further Connections Of The Thermostat Assigned To The Application (Deleting The Thermostat Assigned To The Application → Setting The Day And Time)
- 23. Locking Operating Buttons (Operation Related Settings)
- 24. Settings Menu (Switching Functions → Setting Functions → Exiting Settings Menu)
- 25. Selecting Switching Sensitivity (Defining Maximum Settable Temperature → Defining Minimum Settable Temperature → Calibration Of The Temperature Sensor → Antifreezing → Setting The Keylock Function → Changing Between Heating Or Cooling Mode)
- 26. Calibration Of The Temperature Sensor (adj) (Antifreezing (fre) → Memorizing On/off Status In Case Of A Power Failure (pon))
- 27. 11.5. Changing Between Heating Or Cooling Mode (fun) (11.6. Restoring Default Setting (fac) → 11.7. Delay Of Receiver Unit Outputs → Pump Output)
- 28. Output Delay Function (Switching Between On And Off Positions And Modes Of The Device → Manual Mode → Programmed Auto Mode)
- 29. Manual Mode (Programmed Auto Mode → Description Of The Programmed Mode)
- 30. +2 Mode (+1 Mode → +0 Mode → Description Of The Steps Of Programming → Using Phone Application)
- 31. To Complete Programming And Return To The Screen Belonging To The Thermostat Touch The Icon In The Upper Left Corner. Programs That Were Set…
- 32. Modifying Temperature Until The Next Switch In The Program (Practical Advices, Tackling Any Problems That May Occur → Problem With The Wi-fi Connection → Use Of The Application)
- 33. Frequently Asked Questions
- 34. Műszaki Adatok (Termosztát (adó) Műszaki Adatai)
- 35. Power Supply Voltage (Standby Power Consumption → Max. 0.5 W → Switchable Voltage Of The Relay That Controls The Boiler → Max. 30 V Dc / 250 V Ac → Switchable Current Of The Relay That Controls The Boiler)
- 36. The Computherm Type Wi-fi Thermostat E800rf (Complies With Directives Red 2014/53/eu And Rohs 2011/65/eu → Manufacturer: Quantrax Ltd → Country Of Origin: Kína)
×
COMPUTHERM E800RF Multizone Wi-Fi Thermostat Instruction Manual
The COMPUTHERM E800RF type Wi-Fi thermostat
complies with directives RED 2014/53/EU and RoHS 2011/65/EU.
Manufacturer:
QUANTRAX Ltd.
H-6726 Szeged, Fülemüle u. 34.
Telephone: +36 62 424 133 • Fax: +36 62 424 672
E-mail: iroda@quantrax.hu
Country of origin:
Kína
Copyright © 2024 Quantrax Ltd. All rights reserved.
| General | Details |
|---|---|
| Name | COMPUTHERM E800RF Multizone Wi-Fi Thermostat Instruction Manual |
| Make | COMPUTHERM |
| Language | English |
| Filetype | PDF (Download) |
| File size | 1.03 MB |

COMPUTHERM Q20 Programmable Digital Room Thermostat Instruction Manual
COMPUTHERM Q5RF Multi Zone Wireless Digital Room Thermostat Instruction Manual


Danfoss ECtemp Next Plus Electronic Intelligent Timer Thermostat Installation Guide

WHITE-RODGERS 1F90-71 5-Day 2-Day Electronic Digital Thermostat Instruction Manual

Network Thermostat X7C-WIFI Smart Touchscreen Thermostat Instruction Manual

Roth Minishunt Room Thermostat Installation Guide

BOSCH BCC110 Connected Control Thermostat Instruction Manual

BEOK TS4 Series Wi-Fi Touch Screen Thermostat User Manual

GENERAL ARUNA FH25S Underfloor Heating Thermostat User Manual

degrii THM-C Smart Thermostat Installation Guide

STEGO ET 011 Electronic Thermostat User Manual

TCL IPOWER Heat Mat Thermostat Instruction Manual
Table of Contents
- 1. Computherm E800rf - Multizone Wi-fi Thermostat →
- 2. Page 2 →
- 3. A General Description Of The Thermostat - Important Warnings... →
- 4. 10.2. Disabling Further Connections Of The Thermostat Assign... →
- 5. 1. General Description Of The Thermostat →
- 6. An Example Of Dividing The Heating System Into Zones Is Show... →
- 7. Chapter 7 For Installation, Connection And Synchronization O... →
- 8. Reliably →
- 9. Led Marked: Pump - Blue Led, Marked: Boiler →
- 10. 4. Information Appearing On The Display Of The Thermostat →
- 11. Functions Accessible In The Phone Application →
- 12. Location Of The Thermostat And The Receiver Unit - Installat... →
- 13. Connection And Installation Of The Thermostats And The Recei... →
- 14. Putting The Receiver Unit Into Operation - Connecting The Co... →
- 15. The Back Of The Receiver - Heating Unit (boiler) →
- 16. Synchronization Of The Thermostat And The Receiver Unit →
- 17. Attention! - The Thermostat Synchronizes With The Receiver W... →
- 18. Setting Up The Internet Control - Installing The Application →
- 19. Connecting The Thermostat To A Wi-fi Network - Synchronizati... →
- 20. Connecting The Thermostat To The Application - Controlling A... →
- 21. Operation Of The Thermostat - Basic Settings →
- 22. Disabling Further Connections Of The Thermostat Assigned To ... →
- 23. Locking Operating Buttons - Operation Related Settings →
- 24. Settings Menu - Switching Functions →
- 25. Selecting Switching Sensitivity - Defining Maximum Settable ... →
- 26. Calibration Of The Temperature Sensor (adj) - Antifreezing (... →
- 27. 11.5. Changing Between Heating Or Cooling Mode (fun) - 11.6.... →
- 28. Output Delay Function - Switching Between On And Off Positio... →
- 29. Manual Mode - Programmed Auto Mode →
- 30. +2 Mode - +1 Mode →
- 31. To Complete Programming And Return To The Screen Belonging T... →
- 32. Modifying Temperature Until The Next Switch In The Program -... →
- 33. Frequently Asked Questions →
- 34. Műszaki Adatok - Termosztát (adó) Műszaki Adatai →
- 35. Power Supply Voltage - Standby Power Consumption →
- 36. The Computherm Type Wi-fi Thermostat E800rf - Complies With ... →






































