COMPUTHERM E800RF Multizone Wi-Fi Thermostat Instruction Manual

the back of the receiver  
heating unit (boiler)  
230 V AC  
50 Hz  
230 V AC  
50 Hz  
zone valves  
A COMPUTHERM E800RF vevőegység csatlakozóinak méretei max. 2-3 párhuzamosan kapcsolt készülék  
(zónaszelep, szivattyú, stb.) vezetékeinek fogadására alkalmasak. Ha egy zónakimenethez ennél több ké-  
szüléket (pl. 4 db zónaszelepet) kíván párhuzamosan csatlakoztatni, akkor azok vezetékeit még a bekötés  
előtt közösítse és csak a közös vezetéket csatlakoztassa a zónavezérlőhöz.  
When using slow-acting electrothermal zone valves, if all zone valves are closed in the default position  
without heating, it is recommended to delay the start of the boiler in order to protect the boiler pump. You  
can find more information about the delay of the outputs in Chapter 11.7.  
7.2.2. Connecting the receiver unit to the mains  
The 230 V power supply should be connected to the terminals marked N-L inside the receiver unit with  
a two-wire cable. This provides power to the receiver, but this voltage does not appear on the output  
connection points (NO, COM and NC) of the boiler control relay. The neutral wire of the network must be  
connected to the „N” point, while the phase wire must be connected to the „L” point. It is not necessary  
- 15 -  
GeneralDetails
NameCOMPUTHERM E800RF Multizone Wi-Fi Thermostat Instruction Manual
MakeCOMPUTHERM
LanguageEnglish
FiletypePDF (Download)
File size1.03 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
COMPUTHERM Q20 Programmable Digital Room Thermostat Instruction Manual
COMPUTHERM Q20 Programmable Digital Room Thermostat Instruction Manual
COMPUTHERM Q5RF Multi Zone Wireless Digital Room Thermostat Instruction Manual
COMPUTHERM Q5RF Multi Zone Wireless Digital Room Thermostat Instruction Manual

COMPUTHERM E800RF Multizone Wi-Fi Thermostat Instruction Manual