This Thermostat is powered by 24VAC only. It requires 24VAC (Rh and/or Rc and C terminals) of the low‐  
voltage transformer to be connected to it for proper operaꢀon. It will not operate without these 2  
connecꢀons.  
Rh and Rc are connected via the shunt jumper (see Fig. 1). For applicaꢀons using two 24VAC  
transformers, one in the indoor unit and one in the outdoor unit, remove the shunt jumper (Fig. 1).  
Connect the common from each to the C terminal. Connect R from the indoor unit to the Rh terminal.  
Connect R from the outdoor unit to the Rc terminal. The W signals are taken from the Rh power and the  
Y signal is taken from the Rc power. If Thermostat has been installed in a two—transformer applicaꢀon  
that is later changed to a single—transformer installaꢀon, installer must install a field supplied jumper  
between Rc and Rh.  
Fig. 1 – Shunt Jumper  
Accessory Output and Connecꢀons  
This thermostat is equipped with a dry contact output for the management of humidifiers, dehumidifiers  
and venꢀlaꢀon equipment. The 2 terminals are both labeled as ACC. The dry contact output must be  
configured for the management of either one of them.  
Venꢀlaꢀon/ERV/HRV  
Funcꢀon will be acꢀvated for the % on ꢀme configured, using a cycle rate of 1h. For example, if it is set  
to 50%, funcꢀon will be acꢀve for the first 30min and inacꢀve for the next 30min. If the difference in  
temperature is larger than the defined max indoor/outdoor temp delta, the funcꢀon will never acꢀvate.  
If the outdoor temperature is not available, the thermostat will sꢀll follow the percent on ꢀme,  
disregarding the max delta parameter.  
Humidifier  
Control will be based on a setpoint (which will trigger the acꢀvaꢀon of the funcꢀon) and a pre‐defined  
hysteresis of 5% above the setpoint. If humidifier with acꢀve heat opꢀon is selected, the humidifier will  
only be acꢀvated when the heat is running, regardless of the humidifier setpoint.  
Dehumidifier  
GeneralDetails
NameCarrier Wi-Fi Enabled 24V Smart Thermostat Instruction Manual
MakeCarrier
LanguageEnglish
FiletypePDF (Download)
File size0.55 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Carrier 53DFS250-SL Programmable Digital Thermostat Owner’s Manual
Carrier 53DFS250-SL Programmable Digital Thermostat Owner’s Manual
Carrier 33TWSPL-4 Wifi Stat Plus Thermostat Owner’s Manual
Carrier 33TWSPL-4 Wifi Stat Plus Thermostat Owner’s Manual
Carrier EB-STATE3LTICB-01 lLite Smart Thermostat Instructions
Carrier EB-STATE3LTICB-01 lLite Smart Thermostat Instructions
Carrier ecobee3 Lite Smart Thermostat User Manual
Carrier ecobee3 Lite Smart Thermostat User Manual
Carrier EB-STATE7ICR-01 Ecobee for Smart Thermostat Owner’s Manual
Carrier EB-STATE7ICR-01 Ecobee for Smart Thermostat Owner’s Manual
Carrier TSTATCCEWF-01 Smart Thermostat Owner’s Manual
Carrier TSTATCCEWF-01 Smart Thermostat Owner’s Manual
Carrier 33WIFISTAT43 Wi-Fi Thermostat Installation Guide
Carrier 33WIFISTAT43 Wi-Fi Thermostat Installation Guide

Carrier Wi-Fi Enabled 24V Smart Thermostat Instruction Manual