system types. Use Fan buꢁon to select your HVAC type and sub‐system type. Use Mode buꢁon  
to go back.  
a. Supported HVAC system types are as follows:  
i. Standard (L1). Standard supports the following sub‐system types:  
0 Heat 1 Cool (01)  
If selected, you will be presented with addiꢀonal choices to include  
o
Fan. Use Up and Down arrows to cycle through the two choices. No  
fan is represented by F0. Yes fan is represented by F1. Use Fan buꢁon  
to select.  
0 Heat 2 Cool (02)  
If selected, you will be presented with addiꢀonal choices to include  
o
Fan. Use Up and Down arrows to cycle through the two choices. No  
fan is represented by F0. Yes fan is represented by F1. Use Fan buꢁon  
to select.  
1 Heat 0 Cool (10)  
If selected, you will be presented with addiꢀonal choices to include  
o
Fan. Use Up and Down arrows to cycle through the two choices. No  
fan is represented by F0. Yes fan is represented by F1. Use Fan buꢁon  
to select.  
2 Heat 0 Cool (20)  
If selected, you will be presented with addiꢀonal choices to include  
o
Fan. Use Up and Down arrows to cycle through the two choices. No  
fan is represented by F0. With fan is represented by F1. Use Fan  
buꢁon to select.  
1 Heat 1 Cool (11)  
If selected, you will be presented with addiꢀonal choices to include  
o
Fan. Use Up and Down arrows to cycle through the two choices. No  
fan is represented by F0. Yes fan is represented by F1. Use Fan buꢁon  
to select.  
2 Heat 1 Cool (21)  
If selected, you will be presented with addiꢀonal choices to include  
o
Fan. Use Up and Down arrows to cycle through the two choices. No  
fan is represented by F0. Yes fan is represented by F1. Use Fan buꢁon  
to select.  
1 Heat 2 Cool (12)  
If selected, you will be presented with addiꢀonal choices to include  
o
Fan. Use Up and Down arrows to cycle through the two choices. No  
fan is represented by F0. Yes fan is represented by F1. Use Fan buꢁon  
to select.  
2 Heat 2 Cool (22)  
If selected, you will be presented with addiꢀonal choices to include  
Fan. Use Up and Down arrows to cycle through the two choices. No  
o
fan is represented by F0. Yes fan is represented by F1. Use Fan buꢁon  
to select.  
ii. Heat Pump (L2). Heat Pump supports the following sub‐system types:  
1 Stage (10)  
If selected, you will be presented with addiꢀonal choices for  
o
changeover. Use Up and Down arrows to cycle through the two  
choices. With cool is represented by 01. With heat is represented by  
02. This selects the reversing value energized. Use Fan buꢁon to  
select.  
1 Stage with Aux (11)  
o
If selected, you will be presented with addiꢀonal choices for  
changeover. Use Up and Down arrows to cycle through the two  
choices. With cool is represented by 01. With heat is represented by  
02. This selects the reversing value energized. Use Fan buꢁon to  
select.  
o
1 Stage with 2 Stage Aux (12)  
o
If selected, you will be presented with addiꢀonal choices for  
changeover. Use Up and Down arrows to cycle through the two  
choices. With cool is represented by 01. With heat is represented by  
02. This selects the reversing value energized. Use Fan buꢁon to  
select.  
o
2 Stage (20)  
o
If selected, you will be presented with addiꢀonal choices for  
changeover. Use Up and Down arrows to cycle through the two  
choices. With cool is represented by 01. With heat is represented by  
02. This selects the reversing value energized. Use Fan buꢁon to  
select.  
o
2 Stage with Aux (21)  
o
If selected, you will be presented with addiꢀonal choices for  
changeover. Use Up and Down arrows to cycle through the two  
choices. With cool is represented by 01. With heat is represented by  
02. This selects the reversing value energized. Use Fan buꢁon to  
select.  
o
iii. Dual Fuel (L3). Dual Fuel supports the following sub‐system types:  
1 Stage HP, 1 Heat (11)  
If selected, you will be presented with addiꢀonal choices for  
o
changeover. Use Up and Down arrows to cycle through the two  
choices. With cool is represented by 01. With heat is represented by  
02. This selects the reversing value energized. Use Fan buꢁon to  
select.  
o
2 Stage HP, 1 Heat (21)  
o
If selected, you will be presented with addiꢀonal choices for  
changeover. Use Up and Down arrows to cycle through the two  
choices. With cool is represented by 01. With heat is represented by  
02. This selects the reversing value energized. Use Fan buꢁon to  
select.  
o
1 Stage HP, 2 Heat (12)  
o
If selected, you will be presented with addiꢀonal choices for  
changeover. Use Up and Down arrows to cycle through the two  
choices. With cool is represented by 01. With heat is represented by  
02. This selects the reversing value energized. Use Fan buꢁon to  
select.  
o
4. Aꢂer the last parameter is selected, manual configuraꢀon will be done, and current temperature  
will be shown on the display. The thermostat will default to off, fan auto, and will be ready to  
use.  
SYSTEM START‐UP AND CHECKOUT  
The Thermostat is designed with a built‐in installer test capability, Output Test Mode. This allows for  
easy operaꢀon of equipment without delays or setpoint adjustments to force heaꢀng or cooling. To use  
this feature you must first configure the thermostats HVAC type via Manual Setup of Thermostat HVAC  
Configuraꢀon on the Thermostat or via the installer mobile app.  
To enable and use installer Output Test Mode take the following steps:  
1. Hold the Mode key for 10 seconds (only works if system is configured).  
2. Once Output Test Mode is entered the Thermostat will display S0.  
3. When in the Output Test Mode:  
a. Use the Mode buꢁon to go back.  
b. Use the Fan buꢁon to select.  
c. Use Up and Down buꢁons to cycle through opꢀons.  
4. Stages or Modes available for test are dependent on the HVAC configuraꢀon which has been  
setup. Only those applicable to the selected HVAC type will be shown. The supported test types  
are as follows:  
a. Test Heat Stage 1 (H1)  
b. Test Heat Stage 2 (H2)  
c. Test Auxiliary Heat Stage 1 (A1)  
d. Test Auxiliary Heat Stage 2 (A2)  
e. Test Cool Stage 1 (C1)  
f. Test Cool Stage 2 (C2)  
g. Stop Tesꢀng (S0)  
5. Use the Up and Down arrows to cycle through the available types and press Fan to select the  
type you want to test.  
6. Aꢂer selecꢀon the test funcꢀon will override temperature setpoint for 20min to test heat, cool  
or auxiliary heat. Test will end by selecꢀng a new test (will start the new selected test), selecꢀng  
stop tesꢀng, or 20min ꢀmeout. While tesꢀng the appropriate mode icon and perimeter lighꢀng  
will blink unꢀl test has finished or is stopped.  
OPERATIONAL INFORMATION  
User Interface  
The display is a dead front display. All digits, icons, and perimeter lighꢀng will be off unless the proximity  
sensor is acꢀvated, a key is pressed by the user, or unless a heaꢀng or cooling call occurs. The first key  
touch will be ignored if the display was off unless the thermostat had already been woken up by the  
proximity sensor. Once the display has been woken up the ambient temperature will be shown on the  
segmented display. The up and down temperature arrows, the applicable mode and fan icons, the Wi‐Fi  
on or off icon and OpenADR (if acꢀve) will light up.  
*
Timers  
Five‐‐Minute Compressor Timeguard  
This ꢀmer prevents compressor from starꢀng unless it has been off for at least 5 minutes.  
Cycle Timer  
To prevent short cycling of the HVAC system, especially in the case where compressors are involved, the  
number of cycles per hour will be limited. This will be a seꢁable parameter through the HVAC  
configuraꢀon in the App. Heaꢀng and cooling cycles will be set independently.  
For heaꢀng the following minimum run ꢀme (MRT) and minimum off ꢀme (MOT) defaults will be applied  
based on the number of cycles per hour:  
Standard Gas – MRT = 7, MOT = 5 (5 Cycles per hour)  
Standard Elec – MRT = 5, MOT = 3 (7.5 Cycles per hour)  
Heat pump – MRT = 15, MOT = 5 (3 Cycles per hour)  
For cooling, the following MRT and MOT defaults will be applied based on the number of cycles:  
AC/HP ‐ MRT = 15, MOT = 5 (3 Cycles per hour)  
GeneralDetails
NameCarrier Wi-Fi Enabled 24V Smart Thermostat Instruction Manual
MakeCarrier
LanguageEnglish
FiletypePDF (Download)
File size0.55 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Carrier 53DFS250-SL Programmable Digital Thermostat Owner’s Manual
Carrier 53DFS250-SL Programmable Digital Thermostat Owner’s Manual
Carrier 33TWSPL-4 Wifi Stat Plus Thermostat Owner’s Manual
Carrier 33TWSPL-4 Wifi Stat Plus Thermostat Owner’s Manual
Carrier EB-STATE3LTICB-01 lLite Smart Thermostat Instructions
Carrier EB-STATE3LTICB-01 lLite Smart Thermostat Instructions
Carrier ecobee3 Lite Smart Thermostat User Manual
Carrier ecobee3 Lite Smart Thermostat User Manual
Carrier EB-STATE7ICR-01 Ecobee for Smart Thermostat Owner’s Manual
Carrier EB-STATE7ICR-01 Ecobee for Smart Thermostat Owner’s Manual
Carrier TSTATCCEWF-01 Smart Thermostat Owner’s Manual
Carrier TSTATCCEWF-01 Smart Thermostat Owner’s Manual
Carrier 33WIFISTAT43 Wi-Fi Thermostat Installation Guide
Carrier 33WIFISTAT43 Wi-Fi Thermostat Installation Guide

Carrier Wi-Fi Enabled 24V Smart Thermostat Instruction Manual