Braeburn 8205-100-02 Universal Smart Wi-Fi Thermostat Instruction Manual
No. Installer Setting
Displayed Default Available Description of
Setting Settings Available Settings
17 Adaptive Recovery
Mode (ARMTM)
RECOVER
OFF
OFF
ON
Adaptive Recovery Mode is disabled
Adaptive Recovery Mode is enabled
[Not available if non-programmable was selected in setting 1] During ARM, room temperature is recovered by turning
on the heating or cooling up to 3-hours before the end of the set back period. The setpoint temperature is changed to that
of the upcoming program temperature.
18 User Lock
Security Level
USERLOCK
LVL
2
2
1
If locked, all buttons except and are disabled
If locked, only the PROG, HOLD and MENU
buttons are disabled
Selects the level of keypad lockout when the thermostat has been locked by the user. See the User Manual for instructions
on setting the 3-digit lock code and locking/unlocking the thermostat.
ON
Installer Lock disabled
Installer Lock enabled
19 Installer Lock
INSTLOCK
OFF
OFF
When enabled, a 4-digit lock code can be entered in setting 20. This lock code will be required the next time the Installer
Settings menu is accessed. Select OFF to skip the installer lock.
0-9
Select 0-9 for each digit
20 Installer Lock Code
IL CODE
0000
[Only available if Installer Lock was enabled in setting 19] Select a 4-digit lock code (0-9 for each digit) to
lock the Installer Settings menu. The code 0000 is not a valid lock code and cannot be used.
90 - 45
(32˚ to 7˚C) 45°F (32° to 7°C)
Selects the upper setpoint adjustment limit that cannot be exceeded in heat mode.
Select a Heat Setpoint Upper Limit of 90° to
21 Heat Setpoint
HIGH LIM
90
Upper Limit
HEAT
45 - 90 Select a Cool Setpoint Lower Limit of 45° to
(7˚ to 32˚C) 90°F (7° to 32°C)
22 Heat Setpoint
Lower Limit
LOW LIM
HEAT
45
Selects the lower setpoint adjustment limit that cannot be exceeded in heat mode.
45 - 90 Select a Cool Setpoint Lower Limit of 45° to
(7˚ to 32˚C) 90°F (7° to 32°C)
Selects the lower setpoint adjustment limit that cannot be exceeded in cool mode.
23 Cool Setpoint
Lower Limit
LOW LIM
COOL
45
24 Cool Setpoint
Upper Limit
HIGH LIM
COOL
90
90 - 45
Select a Heat Setpoint Upper Limit of 90° to
(32˚ to 7˚C) 45°F (32° to 7°C)
Selects the upper setpoint adjustment limit that cannot be exceeded in cool mode.
NONE
ALL
Clear disabled - no changes made
Clear enabled - factory reset
25 Installer Clear
(factory reset)
CLEAR
NONE
Selecting ALL will return thermostat to all factory default settings. Factory reset will take affect upon exiting
Installer settings menu.
Additional options such as Service Monitors, Setting the Lock Code, etc., are located in the User Settings -
See User Manual.
Installer Manual
10
| General | Details |
|---|---|
| Name | Braeburn 8205-100-02 Universal Smart Wi-Fi Thermostat Instruction Manual |
| Make | Braeburn |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.32 MB |

Braeburn Programmable Touchscreen Thermostat User Manual

Braeburn TH-BR22 Programmable Thermostat Instructions

Braeburn 8205 Universal Smart Wi-Fi Thermostat User Guide

Braeburn 2030 Economy Model Thermostat User Manual

Braeburn 2030 Programmable Thermostat Instruction Manual