Braeburn 8205-100-02 Universal Smart Wi-Fi Thermostat Instruction Manual
3
Wiring
Heat Pump Systems - Typical Wiring Configurations
1 Heat/1 Cool
2 Heat/2 Cool
2 Heat/2 Cool
3 Heat/2 Cool
(w/Aux Heat)
System Type:
HP 32
(w/Aux Heat)
System Type:
HP 22
Wiring
Terminal
Terminal Description
System Type:
HP 11
System Type:
HP 32
Rh
Rc
G
24 VAC Heating Transformer
24 VAC Cooling Transformer
Fan Relay
Rh
-
Rh
-
Rh
-
Rh
-
G
G
G
G
(W1) Conventional Heat Relay
(E) Emergency Heat Relay
E2
-
-
E2
W1/E/W3
W2/AUX
-
-
(W2) 2nd Stage Conventional Heat
(AUX) Heat Pump Auxiliary Heat
AUX2
AUX2
(O) Cool Active Reversing Valve
(B) Heat Active Reversing Valve
(V3) Zone Valve Power Close
O/B1
O/B1
O/B1
O/B1
O/B
Y1
Y2
C
1st Stage Compressor Relay
2nd Stage Compressor Relay
24 VAC Transformer Common
Y1
-
Y1
-
Y1
Y2
C3
Y1
Y2
C3
C3
C3
“System Type” is configured in the Installer Settings - See section 5.
NOTES - Heat Pump Systems
1 O (cool active) or B (heat active) is selected in the Installer Settings menu
2 If no separate emergency heat relay, connect to either AUX or E and Install a field supplied jumper wire
3 24 VAC Common (C wire) connection required
Provide disconnect and overload protection as required.
5
Installer Manual
| General | Details |
|---|---|
| Name | Braeburn 8205-100-02 Universal Smart Wi-Fi Thermostat Instruction Manual |
| Make | Braeburn |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.32 MB |

Braeburn Programmable Touchscreen Thermostat User Manual

Braeburn TH-BR22 Programmable Thermostat Instructions

Braeburn 8205 Universal Smart Wi-Fi Thermostat User Guide

Braeburn 2030 Economy Model Thermostat User Manual

Braeburn 2030 Programmable Thermostat Instruction Manual