Braeburn 8205-100-02 Universal Smart Wi-Fi Thermostat Instruction Manual
3
Wiring
Conventional Systems -Typical Wiring Configurations
Heat Only
System Type:
CONV 11
Cool Only
System Type:
CONV 11
1 Heat/1 Cool 2 Heat/2 Cool
System Type:
CONV 11
Wiring
Terminal
Terminal Description
System Type:
CONV 22
Rh
Rc
G
24 VAC Heating Transformer
24 VAC Cooling Transformer
Fan Relay
Rh
-
-
Rh1
Rc1,2
G
Rh1
Rc1,2
G
Rc
G
G4
(W1) Conventional Heat Relay
(E) Emergency Heat Relay
W1
-
-
W1
-
W1
-
W1/E/W3
W2/AUX
(W2) 2nd Stage Conventional Heat
(AUX) Heat Pump Auxiliary Heat
W24
(O) Cool Active Reversing Valve
(B) Heat Active Reversing Valve
(V3) Zone Valve Power Close
-
-
-
-
O/B
Y1
Y2
C
1st Stage Compressor Relay
2nd Stage Compressor Relay
24 VAC Transformer Common
-
Y1
-
-
-
Y1
Y24
C3, 4
-
C5
C5
C3, 4
“System Type” is configured in the Installer Settings - See section 5.
NOTES - Conventional Systems
1 Remove factory installed jumper for dual transformer systems
2 Only required for dual transformer systems
3 For dual transformer systems, common must come from cooling transformer
4 Only connect if needed for system
5 24 VAC Common (C wire) connection required
Provide disconnect and overload protection as required.
Installer Manual
4
| General | Details |
|---|---|
| Name | Braeburn 8205-100-02 Universal Smart Wi-Fi Thermostat Instruction Manual |
| Make | Braeburn |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.32 MB |

Braeburn Programmable Touchscreen Thermostat User Manual

Braeburn TH-BR22 Programmable Thermostat Instructions

Braeburn 8205 Universal Smart Wi-Fi Thermostat User Guide

Braeburn 2030 Economy Model Thermostat User Manual

Braeburn 2030 Programmable Thermostat Instruction Manual