4. To exit this mode and return to normal operation press  
the (:t:) button.  
A desirable signal strength is at least 2 bars. Below this  
indicates a poor signal strength. When connected there will  
be a small network icon displayed in the bottom right of the  
screen and the signal strength bars will disappear.  
7. Wireless Time:o:stat Location Guide  
Connection problems can be prevented by carefully  
considering the location of the Time:o:stat master and  
receiver at the point of installation.  
The radio frequency (RF) used by the wireless Time:o:stat  
passes easily through internal stud walls but poorly through  
solid brick. RF is also disturbed by metal household  
appliances (such as microwaves, cookers and fridges).  
When wiring the receiver, mount it outside of any cupboard  
and where the line of signal does not travel through the  
boiler itself. (Position A1 is better than B1 in the diagram  
below).  
Typically the wireless Time:o:stat has a range of 15 meters,  
through three stud walls. It will only reliably pass through a  
single solid brick wall and the range will be dramatically  
reduced. The diagram on the following page, shows good and  
bad locations.  
A1 to A2 location GOOD line of signal only passing  
through: one wall  
B1 to B2 location BAD line of signal passing through: two  
walls, cupboard, boiler, microwave and mirror.  
You can check the RF signal quality of the Time:o:stat when  
mounted in the desired location by following the signal  
testing procedure.  