Home > TIME O STAT > TIME O STAT 2 Channel 3 Wired HMO Thermostat Installation Guide
TIME O STAT 2 Channel 3 Wired HMO Thermostat Installation Guide
3. Configuring your Time:o:stat
The Time:o:stat is shipped with the default advanced settings
and locking bitswitch disabled. It is recommended that the
locking bitswitch is enabled following changes to the
advanced settings. This helps prevent tenants tampering with
the advanced settings.
To adjust the advanced settings:
1. Press and hold the button (A) and button (C) then button
(T) for around 3 seconds
2. Setup 1 screen (For selecting countdown duration) will
then be displayed (see the screen below)
3. In the top right of the screen the advanced setting option
being selected is displayed. (in this case 2hr countdown)
Below is the flow of setup screens for the advanced settings.
The table shows the options for each advanced setting. The
default setting is in bold. To change the advanced setting,
cycle the options using the + and – buttons (C) and (D). To
move to the next setup screen, press the (T) button below
the screen.
Screen
Setup 1
Setup 2
Setup 3
Setup 4
Setup 5
Setup 6
Setup 7
Setup 8
INFo
Code
dur
ProG
HIGH
Low
CoFt
SEAS
dEFt
HW
Advanced Setting
Countdown Duration
Auto-Program Duration
Maximum Temperature
Minimum Temperature
Comfort Mode
Options (default in bold)
2hrs, 3hrs
1hr, 2hrs, 3hrs, OFF
o
o
2
8
C
,
2
3
C
14oC, 18oC, 19oC, 20oC, OFF, 7oC
OFF, ON, Night
Seasonal Mode
OFF, ON
Starting Temperature
Hot Water (2-Channel)
Signal Test / Info
21oC, 23oC
Prog (2x3hr durations), ON
RF Signal Strength / Summary
InFo