Danfoss ECtemp Touch Electronic Intelligent Timer Thermostat Installation Guide
| General | Details |
|---|---|
| Name | Danfoss ECtemp Touch Electronic Intelligent Timer Thermostat Installation Guide |
| Make | Danfoss |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.7 MB |

Danfoss RET-MD Electronic Intelligent Dial Setting Thermostat Installation Guide
Danfoss VICUQ24M Icon Programmable II Room Thermostat Installation Guide

Danfoss MBC 8000, MBC 8100 Heavy Duty Thermostat Installation Guide

Danfoss UT 72-UT 73 Universal Thermostat Installation Guide

Danfoss ECtemp 530 Electronic Thermostat Installation Guide

Danfoss 014G0251 Eco Radiator Thermostat User Guide

Danfoss RET230P Electronic Thermostat Instruction Manual

Danfoss 014G0013 Z Wave Radiator Thermostat Installation Guide

Danfoss TP7000 Range Electronic 7 Day Programmable Room Thermostat Installation Guide

Danfoss RET1000 Series Electronic Thermostat User Guide

Danfoss ECtemp Manual: Questions and Answers
Danfoss ECtemp specifications
| Power supply | 220-240 V~, 50/60 Hz |
| Maximum load | Max. 16 A / 3680 W @ 230 V |
| Floor temperature limit | 5-45°C |
| Setpoint range | Room temperature: 5-35°C |
| Sensor | NTC 6.8 k at 25°C |
| Operating temperature | 0° to +30°C |
| Storage temperature | -20°C to +65°C |
| Dimensions | 85 x 85 x 20-24 mm |
| Weight | 103 g |
| Power consumption | Max. 0.40 W |
How do I set the time on my Danfoss ECtemp?
Press the hour numbers and use the arrow keys to adjust. Press to confirm, then repeat for minutes.
- Press the hour numbers on screen.
- Use the < and > arrows to set the hour.
- Press to confirm.
- Press the minutes numbers.
- Use the < and > arrows to set the minutes.
- Press to confirm. Installation Guide, p. 10
What steps do I follow to configure the Danfoss ECtemp Touch during initial setup?
Work through the setup wizard to choose sensor type, flooring, room type, heating load, and timer settings.
- Press SETUP WIZARD on the info screen.
- Select floor sensor configuration with < and > arrows, press to confirm.
- Choose the installed floor sensor type using arrows, press to confirm.
- Select flooring type with arrows, press to confirm.
- Choose room type using arrows, press to confirm.
- Select heating element load or "- -" if unknown, press to confirm. Installation Guide, p. 12
Can I skip the setup wizard if I already configured my Danfoss ECtemp online?
Yes. Press ENTER CODE instead of SETUP WIZARD and go directly to entering your web-generated hexacode. Installation Guide, p. 11
How can you tell if an error occurred on Danfoss ECtemp Touch?
A warning symbol appears in the upper left corner of the temperature display. Press it to see more information about the error. Installation Guide, p. 19
What is the maximum floor temperature setting for Danfoss ECtemp with wooden flooring?
35°C. Higher temperatures risk overheating the floor, and a floor sensor must always be used with wooden floors or similar materials. Installation Guide, p. 17
Danfoss ECtemp compared with other Danfoss thermostats
| Specification | Danfoss ECtemp | Danfoss ECtemp Next Plus | Danfoss DEVIreg 316 | Danfoss DEVIreg 530 |
|---|---|---|---|---|
| Power supply | 220-240 V~, 50/60 Hz | 85-250V~, 50/60 Hz | 220 - 240V~, 50Hz | 220-240V~, 50Hz |
| Setpoint range | Room temperature: 5-35°C | Room temperature: 5-35°C | -10 ° to +50 °C | 5-45°C with floor |
| Sensor | NTC 6.8 k at 25°C | Floor Sensor NTC 15 kΩ | NTC 15 kOhm at 25 °C | NTC 15kOhm at 25°C |
| Operating temperature | 0° to +30°C | -10°C to +60°C | -10 °C to +45 °C | -10 to +30°C |
| Storage temperature | -20°C to +65°C | -20°C to +65°C | -20 °C to +65 °C | -20 to +65°C |
| Dimensions | 85 x 85 x 20-24 mm | 86 x 86 x 16/40.5 mm | 86 x 36 x 58 mm | 85 x 85 x 36 mm |
| Weight | 103 g | 103 g | 180 g | 90 g |
| Power consumption | Max. 0.40 W | 0,4 W | Max 0.25W | Max 0.25W |