9. 2-Channel Time:o:stat Installation Guide  
An electrician is required to install the Time:o:stat.  
Wiring the Wireless Receiver mounting bracket:  
1. Remove the mounting bracket by loosening the  
holding screw through the front.  
2. Isolate the power to the boiler at the fused spur.  
3. Using 5A mains rated 3184Y flex follow the wiring  
instructions in the diagram and outlined below.  
4. Connect the Live 1 and Neutral 2 from the wiring  
centre to the L and N terminals on the Time:o:stat  
mounting bracket.  
5. Connect 5 in the wiring centre to 4 (CH-ON N/O)  
on the mounting bracket.  
6. Connect 6 in the wiring centre to 3 (HW-ON N/O)  
on the mounting bracket  
7. For Y Plan system, connect 7 in the wiring centre  
to 1 (HW-OFF N/C) on the mounting bracket  
8. Check the wiring centre is correctly configured.  
9. Secure the wired mounting bracket to the wall.  
10. Ensure the dip switch settings 1 2 3 4 viewed  
through the rectangular aperture on the back of  
the receiver match those in the same aperture on  
the Time:o:stat controller. These designate the  
radio frequency (RF) communication channel.  
11. Hook and push the Time:o:stat receiver front  
panel onto the wired mounting plate so the  
connecting pins push into the terminal blocks and  
lock into place with the connecting screw through  
the front of the receiver case.  