Home > TIME O STAT > TIME O STAT 2 Channel 3 Wired HMO Thermostat Installation Guide
TIME O STAT 2 Channel 3 Wired HMO Thermostat Installation Guide
1. Introduction & Features
Time:o:stat is a thermostat designed for HMO and 'bills
included' rental properties. The Time:o:stat is tamper-proof
and easy to use. It regulates temperature while controlling
the heating period through a time delay countdown timer.
When the time runs out the heating shuts down. This
lowers heating bills while still allowing tenants to operate the
heating when home – helping reduce wasted energy.
Time:o:stat is a room thermostat and can be used to replace
an existing room thermostat. Typically a single Time:o:stat is
required per house. (Unless the house has multiple boilers or
separate switched heating zones).
Time:o:stat is available in four different models: Wired
(Battery), Wired (Mains), Wireless and 2 channel.
Time:o:stat Features
1.1 Countdown Heating duration
1.2 Auto-Program modes
1.3 Maximum Temperatures
1.4 Minimum Temperatures
1.5 Comfort Warmth Mode
1.6 Night Comfort Mode Restriction
1.7 Seasonal Mode
1.8 Hot Water Modes (2 Channel only)
Featured settings can be changed by following the guide for
advanced settings setup in section 3.
1.1 Countdown Heating duration (Default 2 hours)
The Time:o:stats main operating mode involves setting a
desired temperature and time duration for the heating
period. The default maximum duration a user can set for
each heating period is 2 hours. When this time has elapsed
the heating will stop. Time can be added to the Time:o:stat
at any point to re-start or prolong the heating period to the
set duration limit. The default duration limit is 2 hours but
| General | Details |
|---|---|
| Name | TIME O STAT 2 Channel 3 Wired HMO Thermostat Installation Guide |
| Make | TIME O STAT |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.17 MB |