The PSP511A/PSP511LA is protected against normal static electric discharges. To  
minimize the risk of damaging the unit in extremely dry weather, touch a grounded  
metal object before touching your thermostat.  
IN STALLATION  
PSP511A / PSP511LA SERIES  
SMART TEMP® ELECTRONIC THERMOSTAT  
Please read all instructions carefully before beginning installation.  
C
A
U
T
I
O
N
Turn off electricity to the appliance before installing or  
servicing thermostat or any part of the system. Do not turn  
electricity back on until work is completed.  
F
OF  
Easy as  
1–2–3  
Do not short (jumper) across electric terminals on furnace or air conditioner to test  
the system. This may damage the thermostat and void your warranty.  
All wiring must conform to local codes and ordinances.  
Installs Easily  
Set Day and Time  
Choose Heat or Cool  
43377-05  
LUX PRODUCTS CORPORATION  
Mt. Laurel, New Jersey 08054, USA  
The thermostat should be limited to a maximum of 1.5 amps; higher current may  
cause damage to the thermostat.  
WARNING: Use Energizer® or DURACELL® Alkaline Batteries Only.  
Energizer® is a registered trademark of Eveready Battery Company, Inc.  
DURACELL® is a registered trademark of The Gillette Company, Inc.  
Your thermostat is a precision instrument. Please handle it with care.  
TOOLS REQUIRED  
I M P O R T A N T !  
#1 Phillips screwdriver (small)  
Please read all instructions carefully before beginning installa-  
tion. Save them for future reference. Before removing any wiring  
from your existing thermostat, its wires must be labeled with  
their terminal designations. Ignore the color of the wires since  
they may not comply with any standard.  
Drill with 3/16-in. (4.8mm) bit  
Wire stripper/cutter  
THERMOSTAT LOCATION  
On replacement installations, mount the new thermostat in place of the  
old one unless the conditions listed below suggest otherwise. On new  
installations, follow the guidelines listed below.  
Locate the thermostat on an inside wall, about 5 ft. (1.5m) above the floor,  
Thank you for your confidence in our product. To obtain the best results from  
your investment, please read these instructions and acquaint yourself with your  
purchase before installing your new thermostat. Then follow the installation pro-  
cedures, one step at a time. This will save you time and minimize the chance of  
damaging the thermostat and the systems it controls. These instructions may  
contain information beyond that required for your particular installation. Please  
save for future reference.  
and in a room that is used often.  
Do not install it where there are unusual heating conditions, such as: in  
direct sunlight; near a lamp, television, radiator, register, or fireplace; near hot  
water pipes in a wall; near a stove on the other side of a wall.  
Do not locate in unusual cooling conditions, such as: on a wall separating  
an unheated room; or in a draft from a stairwell, door, or window.  
Do not locate in a damp area. This can lead to corrosion that may shorten  
thermostat life.  
COMPATIBILITY  
Do not locate where air circulation is poor, such as: in a corner or an  
alcove; or behind an open door.  
Do not install the unit until all construction work and painting has been  
completed.  
The PSP511A/PSP511LA can be used with most single stage 24 volt gas, oil  
or electric heating and air conditioning systems, single stage heat pumps, or  
gas millivolt heating systems. It cannot be used with 3 wire zone valves, 120  
volt heating systems, or multi stage heat pumps. Ask your dealer for other LUX  
thermostats to control those systems.  
C
A
U
T I  
O
N
Read instructions carefully before removing any wiring from existing  
thermostat.  
Wires must be labeled before they are removed.  
FEATURES  
Do not allow wires to touch each other or parts on thermostat.  
When removing wires from their terminals, ignore the color of the wires  
MORN  
UP  
DAY  
SET  
TEMPERATURE  
EVE  
DOWN  
NIGHT  
BACKLIT  
since they may not comply with any standard.  
DISPLAY  
(PSP511LA  
ONLY)  
FAN  
SWITCH  
RESET  
SET  
WEEKDAY  
PROGRAM  
SET  
WEEKEND  
PROGRAM  
FAN  
AUTO  
ON  
HEAT  
OFF  
HOLD  
NEXT  
EASY  
PROGRAMMING  
WITH  
COOL  
REMOVING THE OLD THERMOSTAT  
SET  
DAYTIME  
RUN  
1. Switch electricity to the furnace and air conditioner  
LUX SPEED DIAL®  
MODE  
OFF; then proceed with the following steps.  
SWITCH  
2. Remove cover from old thermostat. Most are snap-on  
types and simply pull off. Some have locking screws on  
the side. These must be loosened.  
3. Note the letters printed near the terminals. Attach  
labels (enclosed) to each wire for identification. Remove  
and label wires one at a time. Make sure the wires do not  
SIMPLIFIED INSTRUCTIONS  
fall back inside the wall.  
4. Loosen all screws on the old thermostat and remove it from the wall.  
Heating and Cooling  
Contractor Grade  
Armchair Programmable  
One Year Warranty  
Temperature Hold  
F/C Temperature Display  
12/24 Hr Clock Display  
Adjustable Temperature  
MOUNTING THE PSP511A/PSP511LA  
5. Strip insulation leaving 3/8 in. (9.5mm) bare  
wire ends and clean off any corrosion.  
R
6. Fill wall opening with non-combustible insu-  
lation to prevent drafts from affecting the ther-  
mostat.  
Differential / Cycle Rate  
On Screen Low Battery Indicator  
®
5/2 minute selectable minimum  
Run/Off time provides short cycle  
and compressor protection  
System or Battery Powered  
Illuminated Display (PSP511LA  
Default Energy Star Approved  
Programs  
Attractive design  
Exclusive LUX Speed Dial  
5/2 Programming  
Energy Star Compliant  
4 Periods Per Day  
Battery Free Memory For  
All Programs And Settings  
Temporary Temperature Override  
®
C
A
U
T I  
O
N
only)  
Be careful not to drop the unit or disturb elec-  
tronic parts. Leave the door closed while the  
body is being removed from the base.  
GeneralDetails
NameLUX PSP511A Series Programmable 5-2 Thermostat Instruction Manual
MakeLUX
LanguageEnglish
FiletypePDF (Download)
File size0.25 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
LUX TX700U Universal Thermostat Instruction Manual
LUX TX700U Universal Thermostat Instruction Manual
LUX PSP511A Smart Temp Electronic Thermostat Instruction Manual
LUX PSP511A Smart Temp Electronic Thermostat Instruction Manual
LUX TX500Ub Non Programmable Thermostat Instruction Manual
LUX TX500Ub Non Programmable Thermostat Instruction Manual
LUX TX1500E Programmable Thermostat Instruction Manual
LUX TX1500E Programmable Thermostat Instruction Manual
LUX CAG1500 SERIES Smart Temp Electronic Thermostat Instruction Manual
LUX CAG1500 SERIES Smart Temp Electronic Thermostat Instruction Manual
LUX PSPH521 Series Programmable Heat Pump Thermostat Instruction Manual
LUX PSPH521 Series Programmable Heat Pump Thermostat Instruction Manual
LUX DHP2120 Battery Powered Non Programmable Digital Heat Pump Thermostat Installation Guide
LUX DHP2120 Battery Powered Non Programmable Digital Heat Pump Thermostat Installation Guide
CH200SA Versatile Deluxe Low Voltage Thermostat Installation Guide
CH200SA Versatile Deluxe Low Voltage Thermostat Installation Guide
LUX TH10 Heating Only Mercury FREE Manual Thermostat Instruction Manual
LUX TH10 Heating Only Mercury FREE Manual Thermostat Instruction Manual
LUX PSP511Ca Programmable Thermostat Instruction Manual
LUX PSP511Ca Programmable Thermostat Instruction Manual

LUX PSP511A Series Programmable 5-2 Thermostat Instruction Manual
Get the free PDF manual for the LUX PSP511A Series Programmable 5-2 Thermostat Instruction Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

LUX PSP511A Series Programmable 5-2 Thermostat Instruction Manual Overview

Summary of Contents

  • Page 1: Caution: Complete, easy to read installation and operating instructions. The PSP511A/PSP511LA is protected against normal static electric discharges. Turn off electricity to the appliance before installing or servicing the thermostat. Do not short across electric terminals on the furnace or air conditioner to test the system. All wiring must conform to local codes and ordinances. The thermostat should be limited to a maximum of 1.5 amps; higher current may cause damage. Your thermostat is a precision instrument. Please handle it with care. Before removing any wiring from your existing thermostat, its wires must be labeled with their terminal designations. The PSP511A/PSP511LA can be used with most single stage 24 volt gas, oil, or electric heating and air conditioning systems. Do not install the unit until all construction work and painting has been completed.
  • Page 2: Remove the body from the thermostat’s base by pressing the thumb latch at the bottom center of the unit and swinging the body away. If you are mounting the base to soft material like plasterboard or if you are using the old mounting holes, the screws may not hold. Drill a 3/16 in. (4.8mm) hole at each screw, and insert the plastic anchors provided. Hold the base against the wall. Route the wires through the hole below the terminal block. Using your label and diagrams below, determine appropriate wiring for your system. Slide proper wire between the brass back and black top clamp. Tighten each screw securely. See Setup Options to configure jumpers. Install two new Energizer or DURACELL AA size alkaline batteries at this time. Turn the power back on to your heating and/or air conditioning system.
  • Page 3: Operating instructions for the PSP511A/PSP511LA include two separate programs for heating and cooling, with distinct settings for weekdays and weekends. Each program cycles through four independent periods daily. The device displays the current time, room temperature, and the current program period. The default ENERGY STAR approved program can be restored to factory settings via a software reset. The mode switch has three positions: HEAT, OFF, and COOL. The UP/DOWN keys adjust set temperatures and change settings. Weekday programming allows users to set temperatures and times for each of the four periods: Morning, Day, Evening, and Night. The fan switch has two positions: AUTO and ON. Temperature override allows temporary changes to the set temperature without altering the control programs. A hardware reset button is located on the rear of the unit’s circuit board for reading option jumper positions. Software reset returns all settings to default values and assists in reprogramming. HOLD mode allows for manual temperature control, maintaining a fixed temperature indefinitely without programming.
  • Page 4: Advanced features A thermostat works by turning your heating or cooling system on or off whenever the room temperature varies from the set-point temperature. Your system should cycle on about 3 to 6 times per hour. Use Energizer® or DURACELL® alkaline batteries only. When battery powered, your PSP511A/PSP511LA requires battery replacement at least once a year or when the battery “LO BATT” indicator is visible in the display. The position of J3 sets the minimum length of time that the thermostat must remain with Heat or Cool either on or off before it will automatically switch to the alternate On or Off state. The position of this jumper controls whether temperature is displayed in degrees F° or C°. The position of this jumper controls whether time is displayed in 12 hour or 24 hour Military Time format. To change a setting, the jumper must be repositioned and a hardware reset must be performed. Technical assistance is available through our technical service number. Limited warranty: If this unit fails because of defects in materials or workmanship within one year of date of original purchase, LUX will, at its option, repair or replace it.