ADVANCED FEATURES  
BATTERIES AND MAINTENANCE  
TEMPERATURE SWING  
W
A
R N  
I
N
G
A thermostat works by turning your heating or cooling system on or off whenever the  
room temperature varies from the set-point temperature. This variation is the "swing."  
Your system should cycle on about 3 to 6 times per hour. A smaller swing number  
increases the number of cycles, so room temperature is more constant. A larger swing  
number decreases the number of cycles, but saves energy in most cases.  
Use Energizer® or DURACELL® Alkaline Batteries Only.  
INSTALLING BATTERIES/ MAINTENANCE  
When battery powered, your PSP511A/PSP511LA requires battery replacement at  
least once a year or when the battery “LO BATT” indicator is visible in the display.  
1. Switch electricity to the furnace and air conditioner OFF.  
2. To access your units batteries : Open the door.  
SWING SETTING  
1. With the Dial in its RUN position, simultaneously press NEXT & HOLD.  
2. Use the UP and DOWN keys to change swing.  
3. Choices are 1 through 9. The default is 1.  
3. Using the groove at its top dead center, remove  
the battery holder by rotating it outward from the top.  
4. Remove the used batteries from the rear.  
5. Install two new Energizer® or DURACELL®  
4. Rotate the dial to the RUN position or press NEXT to finish.  
"AA" size ALKALINE batteries in the battery  
compartment. Observe the polarity marking  
shown in the compartment.  
6. Place the notches at the battery door’s bottom into the corresponding tabs inside the  
battery compartment  
HOLD  
NEXT  
Press together  
REPLACE BATTERIES WHEN INDICATOR  
MORN  
DAY  
APPEARS  
4
EVE  
DOWN  
UP  
To change swing  
NIGHT  
7. Rotate the battery holder back into the thermostat body, snapping it into place.  
8. Turn the power back on to your heating and/or air conditioning system. If this is the first  
time you are installing batteries, the thermostat will display "SUN 12:00 AM". Within 90  
seconds the thermostat will begin to display the room temperature alternately with the time.  
To correct the display, see "Setting the TIME and DAY," after you set the programs.  
NEXT  
Dial must be in the RUN position  
Press to set.  
SETUP OPTIONS  
N
O
T E  
JUMPER SETTINGS  
There are three jumpers and one switch. Each controls a setting corresponding to its  
position.  
When replacing batteries, you have approxi-  
mately 1 to 2 minutes before time and day set-  
tings will be lost. All other settings will remain in  
memory.  
MORN  
DAY  
UP  
EVE  
5MIN/2MIN MINIMUM RUN TIME - JP3  
DOWN  
NIGHT  
The position of J3 sets the minimum length of time that the thermostat must remain  
with Heat or Cool either on or off before it will automatically switch to the alternate On or  
Off state. This feature prevents short cycling and provides compressor protection for  
cooling units. Choices are 2 or 5 minutes.  
RESET  
SET  
WEEKDAY  
PROGRAM  
SET  
WEEKEND  
PROGRAM  
FAN  
HEAT  
AUTO  
OFF  
HOLD  
ON  
COOL  
SET  
DAYTIME  
RUN  
TEMPERATURE DISPLAY FORMAT °F/C - JP2  
NEXT  
The position of this jumper controls whether temperature is displayed in degrees or C°  
TIME DISPLAY FORMAT 12/24 HR CLOCK - JP1  
The position of this jumper controls whether time is displayed in 12 hour or 24 hour  
Military Time format.  
REPOSITIONING JUMPERS  
SIMPLIFIED INSTRUCTIONS  
To change a setting, the jumper must be repositioned and a HARDWARE RESET must  
be performed. Note that as long as you press the Hardware Reset button (inside) and not  
the Software Reset button (front), you will change settings and not lose your  
program.These jumpers are located inside the thermostat on the rear of its circuit board.  
To access them, remove the unit from the wall by pressing up on the thumb latch at the  
bottom of thermostat and swinging the body out and away.  
With the batteries installed, this thermostat is “armchair  
programmable.” You can make any program or setting changes with the  
thermostat body off or on the wall thermostat base.  
GAS/ELECTRIC SWITCH  
This switch controls whether the thermostat requests the system fan to run when it is  
in HEAT mode with the fan set to AUTO. Then with the switch set to GAS the fan is con-  
trolled by the heating system itself and the terminal will remain inactive. With the gas  
switch set to Electric (ELEC), the fan is controlled by the thermostat.  
TECHNICAL ASSISTANCE  
If you have any problems installing or using this thermostat, please reread the instruc-  
tions carefully or visit our online technical support at www.luxproproducts.com.  
Technical assistance is available through our Technical Service Number. If you require  
assistance, please call our office between 8:00 a.m. and 4:30 p.m. Eastern Standard  
Time, Monday through Friday. The number is (856) 234-8803.  
The table pictured below is also printed on the circuit board. The closed or shorted  
position is that which covers both a jumpers pins. To prevent its loss in the open posi-  
tion, a jumper may be placed over one pin only.  
After jumpers have been changed, press the HARDWARE RESET button for the changes  
to take effect. See HARDWARE RESET  
WARRANTY  
C
RC  
O
B
RH  
W
Y
G
JUMPERS  
JP3  
JP1  
Limited Warranty: If this unit fails because of defects in materials or workmanship  
within one year of date of original purchase, LUX will, at its option, repair or replace it.  
This warranty does not cover damage by accident, misuse, or failure to follow installation  
instructions. Implied warranties are limited in duration to one year from date of original  
purchase. Some states do not allow limitations on how long an implied warranty lasts, so  
the above limitation may not apply to you. Please return malfunctioning or defective units  
to the participating retailer from which the purchase was made along with proof of pur-  
chase. Please refer to “Technical Assistance” before returning your thermostat.  
Purchaser assumes all risks and liability for incidental and consequential damage result-  
ing from installation and use of this unit. Some states do not allow the exclusion of inci-  
dental or consequential damages, so the above exclusion may not apply to you. This  
warranty gives you specific legal rights and you may also have other rights which vary  
from state to state. Applicable in the U.S.A. only.  
JP2  
GAS/ELECTRIC  
SWITCH  
THERMOSTAT  
WITH BACK  
COVER REMOVED  
CLOSE OPEN  
5MIN 2MIN  
F
12HR 24HR  
JP3  
JP2  
JP1  
C
GeneralDetails
NameLUX PSP511A Series Programmable 5-2 Thermostat Instruction Manual
MakeLUX
LanguageEnglish
FiletypePDF (Download)
File size0.25 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
LUX TX700U Universal Thermostat Instruction Manual
LUX TX700U Universal Thermostat Instruction Manual
LUX TX500Ub Non Programmable Thermostat Instruction Manual
LUX TX500Ub Non Programmable Thermostat Instruction Manual
LUX TX1500E Programmable Thermostat Instruction Manual
LUX TX1500E Programmable Thermostat Instruction Manual
LUX CAG1500 SERIES Smart Temp Electronic Thermostat Instruction Manual
LUX CAG1500 SERIES Smart Temp Electronic Thermostat Instruction Manual
LUX PSP511A Smart Temp Electronic Thermostat Instruction Manual
LUX PSP511A Smart Temp Electronic Thermostat Instruction Manual
LUX PSPH521 Series Programmable Heat Pump Thermostat Instruction Manual
LUX PSPH521 Series Programmable Heat Pump Thermostat Instruction Manual
LUX DHP2120 Battery Powered Non Programmable Digital Heat Pump Thermostat Installation Guide
LUX DHP2120 Battery Powered Non Programmable Digital Heat Pump Thermostat Installation Guide
CH200SA Versatile Deluxe Low Voltage Thermostat Installation Guide
CH200SA Versatile Deluxe Low Voltage Thermostat Installation Guide
LUX TH10 Heating Only Mercury FREE Manual Thermostat Instruction Manual
LUX TH10 Heating Only Mercury FREE Manual Thermostat Instruction Manual
LUX PSP511Ca Programmable Thermostat Instruction Manual
LUX PSP511Ca Programmable Thermostat Instruction Manual

LUX PSP511A Series Programmable 5-2 Thermostat Instruction Manual