Home > LUX > LUX PSP511A Series Programmable 5-2 Thermostat Instruction Manual

LUX PSP511A Series Programmable 5-2 Thermostat Instruction Manual

OPERATING INSTRUCTIONS  
PROGRAMMING  
The PSP511A/PSP511LA provides two separate programs, one for heating the  
other for cooling. Each program has separate settings for weekdays and week-  
ends. Every day a program cycles through four independent periods. You can use  
the default programs or alter them to suit your schedule.  
The PSP511A/PSP511LA alternately displays the current time and the room  
temperature, and the day of the week. The current program period, MORN, DAY,  
EVE or NITE is indicated by an arrow at the left edge of the screen. Set tempera-  
tures are indicated in the right side of the display.  
With batteries installed, you can make program or setting changes with the  
thermostat body on the wall, or conveniently removed from its base plate.  
DEFAULT ENERGY STAR® TEMPERATURE PROGRAM  
As supplied from the factory, the following ENERGY STAR® approved program  
will be used for temperature control in RUN mode. This program and all other  
software settings may be restored to their default values via a SOFTWARE RESET.  
TEMPERATURE CONTROL MODES:  
PERIOD  
Morning 6:00 AM 70°F (21°C) 6:00 AM 78°F (26°C)  
Day 8:00 AM 62°F (17°C) 8:00 AM 85°F (29°C)  
Evening 6:00 PM 70°F (21°C) 6:00 PM 78°F (26°C)  
Night 10:00 PM 62°F (17°C) 10:00 PM 82°F (28°C)  
HEAT MODE  
COOL MODE  
The Mode switch has three positions HEAT, OFF, and COOL. In the winter, set  
the system switch to HEAT to control your heating system. In the summer, set the  
switch to COOL to control your air conditioner. In spring and fall or when the win-  
dows are open, you can set the switch OFF.  
UP/DOWN/CHANGE KEYS:  
EDITING HEAT OR COOL PROGRAMS  
UP/DOWN keys are just right of the unit’s display. They are used to adjust set  
temperatures and change other settings.  
You can review or change any preset times and/or temperatures to suit your  
schedule for each day of the week. The four periods each day are  
Morning(MORN), Day,(DAY) Evening(EVE), and Night(NITE).  
CHANGING TEMPERATURE AND OTHER SETTINGS:  
If there are many choices for a value, usually that setting will automatically  
advance by holding the Up or Down key. Some settings though, must be changed  
one press at a time.  
WEEKDAY PROGRAMMING  
1. Select HEAT or COOL with the mode switch.  
MO TU WE TH FR  
MORN  
DAY  
70  
EVE  
2. Rotate dial to SET WEEKDAY PROGRAMS.  
NIGHT  
6 00  
AM  
DISPLAY ILLUMINATION:  
You will see the display shown here:  
Press any key to illuminate (PSP511LA only) the display. Pressing any key will  
keep the display illuminated until no button has been pressed for approximately  
20 seconds.  
3. All 5 weekday abbreviations will be displayed indicating that this program will  
cycle once each of these days,  
4. The HEAT or COOL set temperature will be displayed on the right side of the dis-  
play. The start time for the displayed period will flash to show that this may be  
changed.  
5. Use the Up and Down keys. One period ends at the start time of the next period.  
The beginning of that period may not be any closer to the beginning of the next peri-  
od than one 15 minute increment.  
FAN MODES:  
The fan switch has two positions; AUTO will automatically run your system’s  
fan as required for heating and cooling only. ON runs your system’s fan continu-  
ously.  
6. Press NEXT to accept the displayed start time and advance to edit the SET TEM-  
PERATURE.  
7. Use the UP and Down keys to change the flashing HEAT or COOL set tempera-  
ture to the temperature you desire.  
N
O
T E  
The FAN switch works only if your system provides a wire for the  
PSP511A/PSP511LA’s G” terminal.  
8. Press NEXT to accept the displayed set temperature and advance to edit the  
start time for the next period. It will be flashing.  
9. Repeat for each of the four periods. When all the periods for the weekday pro-  
gram have been set, the start time for the morning will again be displayed flashing so  
that it may be edited.  
SETTING THE TIME AND DAY:  
Open the door on the front of the thermostat. Rotate the dial to the  
SET DAY/TIME position. You should see the display pictured below with a day of  
the week flashing.  
10. Rotate the dial back to RUN to accept all current values and end the weekday  
programming session.  
Press UP to change day of week.  
MO TU WE TH FR  
WEEKEND PROGRAMMING  
MORN  
Press NEXT to set the time;it will flash.  
1. To review or change the weekend program,  
DAY  
SA SU  
MORN  
Press UP or DOWN to change time of  
EVE  
select HEAT or COOL and rotate the dial to SET  
WEEKEND PROGRAMS. You will see a display  
similar to that shown here:  
DAY  
NIGHT  
AM  
70  
day.  
EVE  
NIGHT  
6 00  
AM  
2. Use steps 4 - 10 described in WEEKDAY  
PROGRAMMING to program Saturday and Sunday.  
When you are finished setting the day and time, rotate the dial to RUN to return to  
normal operation or to another position to continue programming.  
TEMPERATURE OVERRIDE  
OVERRIDE allows you to change the current SET TEMPERATURE in HEAT or  
COOL until the next program period without changing your temperature control  
programs.  
HARDWARE RESET  
This button will read option jumper positions, before the unit begins normal  
operation. It is located inside on the rear of the unit’s circuit board. It is a small  
square component with a white button at it’s center. Pressing Hardware Reset will  
allow the unit to read the new jumper settings without losing your program.  
Press an arrow key once.  
While the Set Temperature is flash-  
MO TU WE TH FR  
MORN  
DAY  
UP  
70  
OVERRIDE  
EVE  
ing; press an UP or DOWN key to  
adjust the set temperature by one  
degree in the associated direction.  
NIGHT  
7 30  
DOWN  
SOFTWARE RESET  
Holding the key will automatically advance the setting in the associated direction.  
Use this front panel RESET to return all software settings and programs to their  
default values. Option jumpers will be read and operation will correspond to their  
current positions. To assist in reprogramming, copy your programs into the chart  
provided before using SOFTWARE RESET.  
The OVERRIDE will be canceled at the start of the next program period, and the  
temperature setting will return to its programmed value.  
An OVERRIDE may be terminated by rotating the dial, switching the mode to OFF,  
or initiating a HOLD.  
Adjusting the set temperature to  
its program value will also cancel an  
OVERRIDE.  
MO TU WE TH FR  
MORN  
P R O G R A M  
M
I N  
G
C H A R T  
DAY  
HOLD  
65  
HOLD  
EVE  
TEMPERATURE HOLD  
HOLD may be used for manual  
temperature control. HOLD is the  
NIGHT  
7 30  
DAY  
PERIOD  
HEAT  
COOL  
TIME  
TEMP.  
TIME  
TEMP.  
MORN  
DAY  
simplest means to set and maintain a fixed temperature. It allows you to set and  
maintain a temperature Set Point indefinitely in Heat or Cool without concern for  
programming. To initiate a HOLD:  
MON.  
THRU  
FRI.  
EVE  
NIGHT  
MORN  
DAY  
Press and release HOLD.  
After the Set Temperature begins to flash, adjust temperature as desired with UP or  
SAT.  
and  
DOWN keys.  
EVE  
Temperature setting will not change until the HOLD is cancelled.  
SUN.  
NIGHT  
To cancel a HOLD, press and release HOLD again, rotate the dial, or switch mode  
to OFF.  
GeneralDetails
NameLUX PSP511A Series Programmable 5-2 Thermostat Instruction Manual
MakeLUX
LanguageEnglish
FiletypePDF (Download)
File size0.25 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
LUX TX700U Universal Thermostat Instruction Manual
LUX TX700U Universal Thermostat Instruction Manual
LUX TX500Ub Non Programmable Thermostat Instruction Manual
LUX TX500Ub Non Programmable Thermostat Instruction Manual
LUX TX1500E Programmable Thermostat Instruction Manual
LUX TX1500E Programmable Thermostat Instruction Manual
LUX CAG1500 SERIES Smart Temp Electronic Thermostat Instruction Manual
LUX CAG1500 SERIES Smart Temp Electronic Thermostat Instruction Manual
LUX PSP511A Smart Temp Electronic Thermostat Instruction Manual
LUX PSP511A Smart Temp Electronic Thermostat Instruction Manual
LUX PSPH521 Series Programmable Heat Pump Thermostat Instruction Manual
LUX PSPH521 Series Programmable Heat Pump Thermostat Instruction Manual
LUX DHP2120 Battery Powered Non Programmable Digital Heat Pump Thermostat Installation Guide
LUX DHP2120 Battery Powered Non Programmable Digital Heat Pump Thermostat Installation Guide
CH200SA Versatile Deluxe Low Voltage Thermostat Installation Guide
CH200SA Versatile Deluxe Low Voltage Thermostat Installation Guide
LUX TH10 Heating Only Mercury FREE Manual Thermostat Instruction Manual
LUX TH10 Heating Only Mercury FREE Manual Thermostat Instruction Manual
LUX PSP511Ca Programmable Thermostat Instruction Manual
LUX PSP511Ca Programmable Thermostat Instruction Manual

LUX PSP511A Series Programmable 5-2 Thermostat Instruction Manual