CH200SA Versatile Deluxe Low Voltage Thermostat Installation Guide
SELECTING THERMOSTAT LOCATION
INSTALLATION
INSTRUCTIONS
The proper location of the room thermostat is most
important to insure that it will provide a comfortable home
temperature. Observe the following general rules when
selecting a location:
1. Locate it about 5 ft. above the floor with a free flow of
air.
2. Install it on a partitioning wall, not on an outside wall.
3. Never expose it to direct light or radiation from lamps,
sun, fireplaces, etc.
4. Avoid locations close to doors that lead outside,
windows, or adjoining outside walls.
5. Avoid locations close to radiators, warm air registers, or
in the direct path of heat from them.
CH200SA & CH400SA
VERSATILE DELUXE LOW
VOLTAGE THERMOSTAT
6. Make sure there are no pipes or duct work in that part of
the wall chosen for the thermostat location.
7. Never locate it in a room that is warmer or cooler than
the rest of the home such as kitchen or hallway or on
the opposite side of the wall of a cold or unused room.
52010
8. The living or dining room is normally a good location,
provided there is no cooking range or refrigerator on
opposite side of wall.
CH200SA
INSTALLATION
1. Remove cover from thermostat by pulling outward. Pull
thermostat wires through small holes beside terminal
screws on thermostat base and connect wires to proper
terminal screws per wiring diagrams. Note that on some
models wire leads may be connected to terminal screws
on back of base.
LUX
2. The thermostat can either be mounted to a standard
horizontal outlet box or mounted directly to the wall.
Place level on top of thermostat base and mark hole
locations for mounting screws.Push excess wire into
wall or switch box and plug up hole to prevent drafts
from affecting thermostat operation. Then attach
thermostat base loosely to wall with the two screws
provided.
CH400SA
3. Again place level on top of thermostat base to be sure it
is level. Then tighten mounting screws securely and
snap on thermostat cover.
LUX
HEATING ANTICIPATOR
The heating side of this thermostat is equipped with an
adjustable heater. Set heater indicator to match the
current rating of the primary control. The heater may be
adjusted for current ratings from .2 to 1.2 Amp.
W A R N I N G
Not for use with compressors without time delays.
Additional adjustments, if necessary, may be made as
follows:
BURNER CYCLES TOO LONG - Set adjustable heater to a
slightly lower dial setting (1/2 division).
SPECIFICATIONS
BURNER CYCLES TOO SHORT - Set adjustable heater to a
slightly higher dial setting (1/2 division).
24 Volts A.C.
Electrical Rating: 24 to 30 Volts A.C.
Heat Anticipator: 0.20 to 1.2 Amp. Max.
Cool Anticipator: 0 to 1.0 Amp. Max.
W A R N I N G
The Adjustable Heater (Heat Anticipator) WILL BURN OUT if 25V
are applied directly to thermostat by shorting out the gas valve or
primary control during testing or by incorrect wiring.
© 2007 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED
1
| General | Details |
|---|---|
| Name | CH200SA Versatile Deluxe Low Voltage Thermostat Installation Guide |
| Make | LUX |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.14 MB |

LUX TX700U Universal Thermostat Instruction Manual

LUX TX500Ub Non Programmable Thermostat Instruction Manual

LUX TX1500E Programmable Thermostat Instruction Manual

LUX CAG1500 SERIES Smart Temp Electronic Thermostat Instruction Manual

LUX PSP511A Smart Temp Electronic Thermostat Instruction Manual

LUX PSP511A Series Programmable 5-2 Thermostat Instruction Manual

LUX PSPH521 Series Programmable Heat Pump Thermostat Instruction Manual

LUX DHP2120 Battery Powered Non Programmable Digital Heat Pump Thermostat Installation Guide

LUX TH10 Heating Only Mercury FREE Manual Thermostat Instruction Manual

LUX PSP511Ca Programmable Thermostat Instruction Manual

CH200SA Versatile Deluxe Low Voltage Thermostat Installation Guide Overview
Summary of Contents
- Page 1: Selecting thermostat location is crucial for maintaining a comfortable home temperature. Locate the thermostat about 5 ft. above the floor with free air flow. Install it on a partitioning wall, avoiding outside walls. Do not expose the thermostat to direct light or radiation. Avoid locations near doors, windows, or outside walls. Keep it away from radiators and warm air registers. Ensure there are no pipes or duct work in the wall where the thermostat is installed. Do not place it in rooms that are significantly warmer or cooler than the rest of the home. The living or dining room is generally a good location, provided there are no heat sources on the opposite wall. The heating side of the thermostat has an adjustable heater for current ratings from 0.2 to 1.2 Amp.
- Page 2: Wiring diagrams Cooling systems Heating systems Fan relay Cooling compressor Heating control Heating transformer Cool transformer Heating/cooling systems 4- or 5-wire with one transformer 5- or 6-wire with two transformers
- Page 3: These diagrams below are provided for new installations or unreferenced wires. Typical hookup for 2-wire 24V heating system and millivolt system. Typical hookup for 3-wire heat system if third wire is fan wire. Typical cooling and heating system (4-wire). Typical cooling and heating system (5-wire). Remove jumper between RH & RC. Note: If you have an electric system and the blower does not operate after installation, find the factory installed yellow wire currently attached to the “Y” terminal and move it to the “A” terminal on the sub-base.
- Page 4: Technical assistance is available for installation or usage problems. Review the instruction manual thoroughly for guidance. Contact the Technical Assistance Department during regular business hours for help. Online technical assistance is available anytime through the company's website. The limited warranty covers defects in materials or workmanship for three years from the original purchase date. The warranty does not cover damage from misuse or failure to follow installation instructions. Return malfunctioning units to the retailer with proof of purchase. The warranty may not apply in some states due to variations in laws. The product does not contain mercury but may replace a unit that does. Proper disposal instructions for mercury should be obtained from local waste management authorities.