SELECTING THERMOSTAT LOCATION  
INSTALLATION  
INSTRUCTIONS  
The proper location of the room thermostat is most  
important to insure that it will provide a comfortable home  
temperature. Observe the following general rules when  
selecting a location:  
1. Locate it about 5 ft. above the floor with a free flow of  
air.  
2. Install it on a partitioning wall, not on an outside wall.  
3. Never expose it to direct light or radiation from lamps,  
sun, fireplaces, etc.  
4. Avoid locations close to doors that lead outside,  
windows, or adjoining outside walls.  
5. Avoid locations close to radiators, warm air registers, or  
in the direct path of heat from them.  
CH200SA & CH400SA  
VERSATILE DELUXE LOW  
VOLTAGE THERMOSTAT  
6. Make sure there are no pipes or duct work in that part of  
the wall chosen for the thermostat location.  
7. Never locate it in a room that is warmer or cooler than  
the rest of the home such as kitchen or hallway or on  
the opposite side of the wall of a cold or unused room.  
52010  
8. The living or dining room is normally a good location,  
provided there is no cooking range or refrigerator on  
opposite side of wall.  
CH200SA  
INSTALLATION  
1. Remove cover from thermostat by pulling outward. Pull  
thermostat wires through small holes beside terminal  
screws on thermostat base and connect wires to proper  
terminal screws per wiring diagrams. Note that on some  
models wire leads may be connected to terminal screws  
on back of base.  
LUX  
2. The thermostat can either be mounted to a standard  
horizontal outlet box or mounted directly to the wall.  
Place level on top of thermostat base and mark hole  
locations for mounting screws.Push excess wire into  
wall or switch box and plug up hole to prevent drafts  
from affecting thermostat operation. Then attach  
thermostat base loosely to wall with the two screws  
provided.  
CH400SA  
3. Again place level on top of thermostat base to be sure it  
is level. Then tighten mounting screws securely and  
snap on thermostat cover.  
LUX  
HEATING ANTICIPATOR  
The heating side of this thermostat is equipped with an  
adjustable heater. Set heater indicator to match the  
current rating of the primary control. The heater may be  
adjusted for current ratings from .2 to 1.2 Amp.  
W A R N I N G  
Not for use with compressors without time delays.  
Additional adjustments, if necessary, may be made as  
follows:  
BURNER CYCLES TOO LONG - Set adjustable heater to a  
slightly lower dial setting (1/2 division).  
SPECIFICATIONS  
BURNER CYCLES TOO SHORT - Set adjustable heater to a  
slightly higher dial setting (1/2 division).  
24 Volts A.C.  
Electrical Rating: 24 to 30 Volts A.C.  
Heat Anticipator: 0.20 to 1.2 Amp. Max.  
Cool Anticipator: 0 to 1.0 Amp. Max.  
W A R N I N G  
The Adjustable Heater (Heat Anticipator) WILL BURN OUT if 25V  
are applied directly to thermostat by shorting out the gas valve or  
primary control during testing or by incorrect wiring.  
© 2007 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED  
1
GeneralDetails
NameCH200SA Versatile Deluxe Low Voltage Thermostat Installation Guide
MakeLUX
LanguageEnglish
FiletypePDF (Download)
File size0.14 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
LUX TX700U Universal Thermostat Instruction Manual
LUX TX700U Universal Thermostat Instruction Manual
LUX TX500Ub Non Programmable Thermostat Instruction Manual
LUX TX500Ub Non Programmable Thermostat Instruction Manual
LUX TX1500E Programmable Thermostat Instruction Manual
LUX TX1500E Programmable Thermostat Instruction Manual
LUX CAG1500 SERIES Smart Temp Electronic Thermostat Instruction Manual
LUX CAG1500 SERIES Smart Temp Electronic Thermostat Instruction Manual
LUX PSP511A Smart Temp Electronic Thermostat Instruction Manual
LUX PSP511A Smart Temp Electronic Thermostat Instruction Manual
LUX PSP511A Series Programmable 5-2 Thermostat Instruction Manual
LUX PSP511A Series Programmable 5-2 Thermostat Instruction Manual
LUX PSPH521 Series Programmable Heat Pump Thermostat Instruction Manual
LUX PSPH521 Series Programmable Heat Pump Thermostat Instruction Manual
LUX DHP2120 Battery Powered Non Programmable Digital Heat Pump Thermostat Installation Guide
LUX DHP2120 Battery Powered Non Programmable Digital Heat Pump Thermostat Installation Guide
LUX TH10 Heating Only Mercury FREE Manual Thermostat Instruction Manual
LUX TH10 Heating Only Mercury FREE Manual Thermostat Instruction Manual
LUX PSP511Ca Programmable Thermostat Instruction Manual
LUX PSP511Ca Programmable Thermostat Instruction Manual

CH200SA Versatile Deluxe Low Voltage Thermostat Installation Guide
Get the free PDF manual for the CH200SA Versatile Deluxe Low Voltage Thermostat Installation Guide and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

CH200SA Versatile Deluxe Low Voltage Thermostat Installation Guide Overview

Summary of Contents

  • Page 1: Selecting thermostat location is crucial for maintaining a comfortable home temperature. Locate the thermostat about 5 ft. above the floor with free air flow. Install it on a partitioning wall, avoiding outside walls. Do not expose the thermostat to direct light or radiation. Avoid locations near doors, windows, or outside walls. Keep it away from radiators and warm air registers. Ensure there are no pipes or duct work in the wall where the thermostat is installed. Do not place it in rooms that are significantly warmer or cooler than the rest of the home. The living or dining room is generally a good location, provided there are no heat sources on the opposite wall. The heating side of the thermostat has an adjustable heater for current ratings from 0.2 to 1.2 Amp.
  • Page 2: Wiring diagrams Cooling systems Heating systems Fan relay Cooling compressor Heating control Heating transformer Cool transformer Heating/cooling systems 4- or 5-wire with one transformer 5- or 6-wire with two transformers
  • Page 3: These diagrams below are provided for new installations or unreferenced wires. Typical hookup for 2-wire 24V heating system and millivolt system. Typical hookup for 3-wire heat system if third wire is fan wire. Typical cooling and heating system (4-wire). Typical cooling and heating system (5-wire). Remove jumper between RH & RC. Note: If you have an electric system and the blower does not operate after installation, find the factory installed yellow wire currently attached to the “Y” terminal and move it to the “A” terminal on the sub-base.
  • Page 4: Technical assistance is available for installation or usage problems. Review the instruction manual thoroughly for guidance. Contact the Technical Assistance Department during regular business hours for help. Online technical assistance is available anytime through the company's website. The limited warranty covers defects in materials or workmanship for three years from the original purchase date. The warranty does not cover damage from misuse or failure to follow installation instructions. Return malfunctioning units to the retailer with proof of purchase. The warranty may not apply in some states due to variations in laws. The product does not contain mercury but may replace a unit that does. Proper disposal instructions for mercury should be obtained from local waste management authorities.