Home > Schneider Electric > Schneider Electric 2290B Programmable Room Thermostat Instruction Manual

Schneider Electric 2290B Programmable Room Thermostat Instruction Manual

(Si Option 01) Si Status  
Enable or disable Service Interval Mode.  
The Drayton Digistat thermostat is a universal thermostat with  
24 hour, 5-2day or 7day program types and up to 8 time/  
temperature events per day and can also be used as a simple  
room thermostat.  
(Si Option 02) Si Type  
Select effect imposed on the heating when service is due.  
(Si Option 03) Service Due Date  
Set date when next service is due.  
Clock Setting  
Your Digistat is fitted with a “real-time clock”, which is pre-set at  
the factory; you will not have to alter the time settings. A special  
feature of this real-time clock is it will automatically change over  
during the GMT/BST summer/winter change-over, removing the  
need to manually alter the clock at these times.  
(Si Option 04) Warning  
Select no. of days before service due date.  
(Si Option 05) Service Due Alarm  
Enable or disable the audible service due alarm.  
General Operation  
(Si Option 06) Si Boost  
Programmable thermostats do not have “On” and “Off” times  
like traditional timers. They offer temperature control both day  
and night and you simply select which temperatures you require  
at each point in the day.  
Enable or disable the Service Boost feature (5 boosts).  
(Si Option 07) Password Reset  
Change the 4 digit PIN. If you forget your Si password, please  
call the Technical Helpline.  
With the unit in “Auto Mode” (the calendar icon is visible at the  
bottom of the screen) the temperature can be changed for a  
short time by using the + and – buttons. Changing the  
temperature in this way will keep the Digistat set to your  
new temperature until the next pre-programmed event (at which  
time it will revert to programmed temperature). The temperature  
you are setting will flash on the screen. Once temperature is set,  
the unit will revert to showing the room temperature again. The  
indicator will show on the screen  
Technical Data  
Power supply  
2x AA 1.5V alkaline batteries  
3(1)A at 230V/50Hz  
Switch type & rating  
Min. recommended  
current  
SPDT (voltage free contacts)  
10mA@24VAC (inductive)  
Operating: 0°C to +40°C  
Storage: -20°C to 65°C  
Ambient temperature  
if the unit is calling for heat.  
Ambient humidity  
(non condensing)  
Programming the Digistat  
20% to 80%, 90% non-condensing  
Your Digistat comes with the following settings  
pre-programmed for your convenience and is suitable for  
those working out of the house during a typical 9-5 pattern.  
When the 5-2day program type is selected the pre-set  
temperatures will be different Mon-Fri and Sat-Sun, as per  
the tables below:  
Temperature range  
Rated impulse voltage  
Ball pressure test  
5°C to 30°C  
4KV  
75°C  
Disconnection means  
Automatic action  
1B  
Pre-set Program 1 (24h, 5-2day weekdays, or 7day):  
100,000 cycles  
2402-2480 MHz  
Event  
1
2
3
4
(5)*  
(6)  
(7)  
(8)  
Operating Frequency  
Time  
06:30 08:30 16:30 22:30  
Max RF Power  
transmitted  
Temperature 20°C 16°C 21°C OFF  
+10dBm  
Pre-set Program 1 (5-2day weekend):  
Pollution situation  
Protection level  
Degree 2  
IP30  
Event  
1
2
3
4
(5)*  
(6)  
(7)  
(8)  
Time  
07:00 09:00 16:00 23:00  
Designed for fixed wiring only, to comply  
with IEE wiring regulations  
Wiring  
Temperature 20°C 18°C 21°C OFF  
*To add these additional time periods manually (max. 8 per day)  
please refer to the steps to the right.  
Energy Class  
IV = 2%  
Relevant EC Directives:  
2014/53/EU (RED)  
2011/65/EU (RoHS)  
2012/19/EU (WEEE)  
®
The Bluetooth word mark and logos are registered trademarks  
EN 60730-1  
Standards:  
owned by Bluetooth SIG, Inc. and any use of such marks by  
Schneider Electric is under license. Other trademarks and trade  
names are those of their respective owners.  
EN 60730-2-7  
EN 60730-2-9 ESTI EN  
300 328 ESTI EN 301  
489 EN 50581  
EN 15500  
GeneralDetails
NameSchneider Electric 2290B Programmable Room Thermostat Instruction Manual
MakeSchneider Electric
LanguageEnglish
FiletypePDF (Download)
File size0.22 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Schneider Electric CCTFR6100Z3 Wiser Radiator Thermostat User Manual
Schneider Electric CCTFR6100Z3 Wiser Radiator Thermostat User Manual
Schneider Electric CFMT02ZB Flush-Mounted Thermostat Instruction Manual
Schneider Electric CFMT02ZB Flush-Mounted Thermostat Instruction Manual
Schneider Electric Wiser Radiator Thermostat Instructions
Schneider Electric Wiser Radiator Thermostat Instructions
Schneider Electric TC-2931 Changeover Thermostat Instruction Manual
Schneider Electric TC-2931 Changeover Thermostat Instruction Manual
Schneider Electric TC900 Series Space Logic Thermostat Instruction Manual
Schneider Electric TC900 Series Space Logic Thermostat Instruction Manual

Schneider Electric 2290B Programmable Room Thermostat Instruction Manual