INSTALLER OPTIONS  
(Option 04) Maximum Setpoint Limit  
Change maximum setpoint temperature. After any changes to  
setpoint limits, all setpoints in AUTO, MANUAL, BOOST and  
HOLIDAY modes will be modified to conform accordingly.  
To make changes to the default Installer Options shown below,  
enter the Installer Options menu by pressing the settings  
button for 3 seconds. This allows access to the User Menu  
01, the Advanced User Settings Menu 02, the Installer Settings  
03, and Service Interval Settings 04. Use the + and - buttons to  
scroll to Installer Options and press O to select. You can exit  
the menu by pressing until you have returned to the home  
screen. In the Installer Options menu (Fig 8), scroll through  
the options using the + and - buttons and press O to select.  
Scroll through the different settings using the + and - buttons  
and press O to select and save. (Fig 9 shows Option 02 OFF).  
(Option 05) Optimum Start  
When enabled, this uses current ambient temperature, the next  
scheduled setpoint and heat gain data captured by the device to  
adjust the thermostat setpoint early, so the ambient temperature  
is at the required level when the next event starts.  
Delayed Start  
When enabled, this uses current ambient temperature, current  
event setpoint and heating characteristics of the environment  
to delay implementation of the setpoint if the ambient  
temperature is already close to it, therefore saving energy.  
(Option 06) Valve Protection Time  
In some hydronic heating systems it may be required to protect  
the valve by operating it for a given time. When enabled, this  
maintenance feature ensures that each relay output is operated  
for at least one (1) minute each week.  
(Fig 8)  
(Fig 9)  
(Option 07) Sensor Fault Function  
(Option 01) Partial Sight Assistant  
In the event of a sensor fault, central heating output is reduced  
to 30% by turning heating ON for 3 minutes, then OFF for 7  
minutes.  
When enabled, audible tones indicate when the setpoint is  
more than, less than or equal to the current room temperature  
when a user manually adjusts the setpoint using the + button:  
Setpoint > room temperature - single high tone per 0.5°C  
increase  
(Option 08) Application Type  
Select the central heating system energy type.  
Setpoint = room temperature - double tone  
Setpoint < room temperature - single low tone per 0.5°C  
decrease  
(Option 09) System Capability  
Select the flow capability of the heating system.  
(Option 13) Installer Settings Lock  
(Option 02) Frost Protection  
When enabled, installers can lock the installer settings menu  
until a 3 digit code is entered. If the code is forgotten while  
device is locked, please call the Technical Helpline.  
The Digistat will switch on the heating if the temperature falls  
to 5°C and maintains a temperature of 7°C even when  
in OFF mode.  
(Option 20) Reset (Service Interval settings are NOT reset)  
Reset the Digistat to its original factory settings.  
(Option 03) Minimum Setpoint Limit  
Change minimum setpoint temperature. After any changes to  
setpoint limits, all setpoints in AUTO, MANUAL, BOOST and  
HOLIDAY modes will be modified to conform accordingly.  
Service Interval Options continued on reverse.  
What is it  
Partial Sight Assistant  
Frost Protection  
Low Set Point C  
High Set Point C  
Optimum Start  
Valve Protection Time (Mins)  
Sensor Fault Function  
Application Type  
System Capability  
Installer Settings Lock  
Reset  
Select between  
Default  
01  
02  
03  
04  
05  
06  
07  
08  
09  
13  
20  
OFF  
ON  
OFF  
High Limit  
30  
Delayed Start  
5
ON  
Electric  
ON  
ON  
5
30  
OFF  
ON  
5
Low Limit  
OFF  
OFF  
OFF  
Gas  
Fast Flow  
OFF  
NO  
Optimum Start  
4
3
2
1
OFF  
OFF  
Gas  
Fast Flow  
OFF  
Oil  
Heat Pump  
Normal/Slow Flow  
ON  
YES  
NO  
01  
02  
03  
04  
05  
06  
07  
Si Status  
Si Type  
Si Due Date  
Si Warning  
Si Due Alarm  
Si Boost  
OFF  
ON  
Heating OFF  
OFF  
Reduced Comfort  
YY/MM/DD  
0
OFF  
No Effect  
Reduced Comfort  
99  
ON  
ON  
30  
OFF  
OFF  
0000  
OFF  
Si Password Reset  
Select 4-digit PIN  
Installation and Quick Start Guide 06490308001 Iss A  
GeneralDetails
NameSchneider Electric 2290B Programmable Room Thermostat Instruction Manual
MakeSchneider Electric
LanguageEnglish
FiletypePDF (Download)
File size0.22 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Schneider Electric CCTFR6100Z3 Wiser Radiator Thermostat User Manual
Schneider Electric CCTFR6100Z3 Wiser Radiator Thermostat User Manual
Schneider Electric CFMT02ZB Flush-Mounted Thermostat Instruction Manual
Schneider Electric CFMT02ZB Flush-Mounted Thermostat Instruction Manual
Schneider Electric Wiser Radiator Thermostat Instructions
Schneider Electric Wiser Radiator Thermostat Instructions
Schneider Electric TC-2931 Changeover Thermostat Instruction Manual
Schneider Electric TC-2931 Changeover Thermostat Instruction Manual
Schneider Electric TC900 Series Space Logic Thermostat Instruction Manual
Schneider Electric TC900 Series Space Logic Thermostat Instruction Manual

Schneider Electric 2290B Programmable Room Thermostat Instruction Manual