Home > PECO > PECO T8168 Performance Pro Thermostat Installation Guide

PECO T8168 Performance Pro Thermostat Installation Guide

CONTROL  
SYSTEMS  
T8168B-2 BACnet® INSTALLATION GUIDE  
THE PECO PERFORMANCE PRO™ T8168 THERMOSTAT  
!
WARNING  
▲
Thank you for choosing a PECO® Performance PRO™ T8168. The T8168 ther-  
mostat is intended for commercial and residential enviroments. It supports both  
programmable and non-programmable operation.  
• READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO  
INSTALL, OPERATE OR SERVICE THIS THERMOSTAT.  
• Failure to observe safety information and comply with instructions could  
result in PERSONAL INJURY, DEATH AND/OR PROPERTY DAMAGE.  
• To avoid electrical shock or damage to equipment, disconnect power  
before installing or servicing and use only wiring with insulation rated for full  
thermostat operating voltage.  
Key features include: auto-changeover; optional remote sensor; three levels of  
keypad lockout with optional PIN access code; a heat/cool Demand Indicator;  
up to four scheduled events per day, a 365-day calendar, 20 holidays, holiday  
override and temporary override.  
Applications  
• Use care to avoid electrostatic discharge.  
• To avoid potential fire and/or explosion do not use in potentially flammable  
or explosive atmospheres.  
The PECO® Performance PRO™ T8168 applications include fan coil, PTAC and  
conventional system with a single, multi speed or 0-10 VDC Fan.  
System Mode Selections: Off-Heat-Cool-Auto  
ON-OFF Heat/Cool Outputs: Up to 2 Heat, 2 Cool  
Proportional Heat/Cool Outputs: Three Wire Floating or 0-10 VDC Control  
Fan Control: Cycling (Auto) or Continuous (On); Up to 3 Speeds or Staged  
Permanent Memory: All device settings are stored in permanent memory.  
Optional Connections: Remote Sensor, Pipe Sensor, Fault Detection and Setback  
• Retain these instructions for future reference.  
• This product, when installed, will be part of an engineered system whose  
specifications and performance characteristics are not designed or  
controlled by PECO® . Review applications and national and local codes to  
assure that the installation will be functional and safe.  
TECHNICAL SPECIFICATIONS  
• WARNING: Disconnect power before beginning installation.  
!
Temperature Control Range: 50° to 90° F (10° to 32° C)  
Differential: 1° F (0.5°C)  
▲
• CAUTION: Use copper wire only  
Input Power: 24 VAC (20-30 VAC) 50/60 Hz (+/- 10%)  
Terminal Connections: 14-24 AWG stranded or solid wire  
Operating Temperature: 0° to 120°F (-18° to 49°C)  
Shipping/Storage Temperature: -20° to 130°F (-29° to 54°C)  
Operating Humidity: 5% to 95% RH, non-condensing  
Physical Dimensions: 4.3” H x 5.7” W x 1.3”D  
Proportional Output Band Width: 2°F (1°C)  
RATINGS  
Outputs: Y1, Y2, W1, W2, G, G1  
24 VAC (20-30 VAC); 50/60 Hz  
10 VA  
Outputs: WD, GD, YD  
Proportional Stroke Time Default: 2 Minutes (Configurable)  
0-10 VDC: Loads must be 1.2K ohms minimum  
4-20 mA: Loads must be 600 ohms maximum  
This thermostat uses triacs switching for accuracy and quiet operation.  
!
CAUTION!  
▲
• 24 VAC low-voltage thermostat.  
• Do not install on voltages higher than 30 VAC.  
• Use copper wire only  
• Use care to avoid electrostatic discharge to the thermostat.  
System Operation  
SM 110  
Service  
Menu  
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
1
4
15  
16  
Heat  
TWF  
1 Cool  
2 Fan  
TWF  
Heat  
1 Cool  
3 Fan  
TWF  
Cool  
1 Heat  
2 Fan  
1 Heat  
1 Cool  
1 Fan  
2 Heat  
1 Cool  
1 Fan  
1 Heat  
1 Cool  
3 Fan  
2 Heat  
1 Cool  
3 Fan  
2 Heat  
2 Cool  
2 Fan  
Heat  
Only  
1 Fan  
Cool  
Only  
1 Fan  
Heat  
Only  
2 Fan  
Cool  
Only  
2 Fan  
Heat  
Only  
3 Fan  
Cool  
Only  
3 Fan  
TWF Heat  
TWF Cool  
2 Fan  
0-10  
VDC  
Only  
SYSTEM  
TYPE  
Cool  
Open  
Cool  
Open  
Y1  
W1  
Y2  
Cool 1  
Cool 1  
Heat 1  
-
Cool 1  
Heat 1  
Cool 1  
Heat 1  
Cool 1  
Heat 1  
COOL 2  
Heat 2  
-
Cool 1  
-
Cool 1  
-
Cool 1  
-
Cool 1  
Cool 1  
-
-
Heat  
Open  
Heat  
Open  
Heat  
Open  
Heat 1  
Heat 1  
-
-
Cool 2  
-
Heat 1  
-
-
Cool 2  
-
Heat 1  
Heat 1  
FAN  
MED  
FAN  
MED  
FAN  
MED  
FAN  
MED  
FAN  
MED  
Cool  
Close  
Cool  
Close  
-
-
Cool2  
-
Heat  
Close  
Heat  
Close  
Heat  
Close  
W2  
Heat 2  
-
Heat 2  
Heat 2  
Heat 2  
Heat 2  
-
Heat 2  
-
G
FAN  
FAN  
FAN HI  
FAN HI  
FAN HI  
FAN  
FAN  
FAN HI  
FAN HI  
FAN HI  
FAN HI  
FAN HI  
FAN HI  
FAN HI  
FAN HI  
-
G1  
Damper  
Damper  
FAN LO  
FAN LO  
FAN LO  
Damper  
Damper  
FAN LO  
FAN LO  
FAN LO  
FAN LO  
FAN LO  
FAN LO  
FAN LO  
FAN LO  
Damper  
YD  
Cool 1  
Heat 1  
Cool 1  
Heat 1  
Cool 1  
Heat 1  
Cool 1  
Heat 1  
Cool 1  
Heat 1  
-
Cool 1  
-
-
Cool 1  
-
-
Cool 1  
-
Cool 1  
Heat 1  
Cool 1  
Heat 1  
Cool 1  
Heat 1  
Cool 1  
Heat 1  
Cool 1  
Heat 1  
WD  
Heat 1  
Heat 1  
Heat 1  
• When System Fan Type (SM112) is set to 1 or 2 (0-10 VDC operation), the GD output is the only fan oputput and G1 provides Damper operation.  
• When Fan Coil 2-Pipe operation is selected the W1 and WD outputs will be disabled. See SM 171.  
© COPYRIGHT 2025 PECO, INC. ALL RIGHTS RESERVED.  
P/N 74599 3220-2406 REV 02  
1
GeneralDetails
NamePECO T8168 Performance Pro Thermostat Installation Guide
MakePECO
LanguageEnglish
FiletypePDF (Download)
File size0.47 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
PECO T372P Thermostat Instruction Manual
PECO T372P Thermostat Instruction Manual
PECO T8168B-2 BACnet Proportional Thermostat Installation Guide
PECO T8168B-2 BACnet Proportional Thermostat Installation Guide
PECO TW180 Thermostat Instruction Manual
PECO TW180 Thermostat Instruction Manual

PECO T8168 Performance Pro Thermostat Installation Guide