WIRING
OPERATING
All electrical installaꢀon work should be carried out by a suitably qualified Electri-
SETTING THE TEMPERATURE
cian or other competent person. If you are not sure how to install this thermostat
consult either with a qualified electrician or heaꢀng Engineer. Do not remove or refit the
appliance onto the base without the mains supply to the system being isolated.
The desired temperature can be set by turning
the dial.
The thermostat can be set at any desired
temperature between 7°C and 30°C.
Important: Please verify that the total start up load of all actuators connected to the
output does not exceed the max. authorized load for the output (value specified in the
technical specificaꢀons). Otherwise, the device could be damaged.
Before carrying out any connecꢀon tasks, switch the equipment off using the circuit
breaker or the control fuse in the power supply circuit.
In operaꢀng, if the ambient temperature is
lower than the preset seꢂng temperature, the
heaꢀng is on and the red indicator switches on.
Make the connecꢀons to all the following terminals according to the relevant schema-
ꢀcs:
Inputs
Outputs
FROST PROTECTION MODE
L
N
N
L
Neutral (internal
bridged on the N
output)
Phase correspon-
ding to thermal
actuators control
This mode enables you to protect your home
against the effects of cold weather by main-
taining a minimum temperature of 8°C in it at
all ꢀmes.
Thermal actuators
neutral
Phase
To acꢀvate Frost protecꢀon mode, posiꢀon
Note:
the cursor opposite the symbol
.
Preferably use wires with a cross-
secꢀon area from 0.5 to 1.5 mm².
E.g.: H05VV-F2X1 (2 x 1mm²)
10mm max.
16mm max.
LIMIT AND LOCK
L N
N L
At the back of the dial you will find two jumpers which enable you to limit the range of
temperatures to which the system can be set.
Switch
live
230V~
50Hz
230V~
50Hz
1A Max.
The jumpers are iniꢀally set
with no limitaꢀon effect. To set
up a blocking effect (minimum,
maximum or temperature range),
remove them using pliers and then
Temperature
put them back in with the help of
points
MOUNTING OF THE FRONT COVER
the reference points.
1- Replace the front cover of thermostat
on the base.
2- Secure the thermostat by screwing the
locking screw under the thermostat.
Example of 3 possibiliꢀes:
Jumper moved from
initial position
- Limiꢀng the minimum
temperature of the system
(MIN)
If the desired temperature must
not drop below 17°C, posiꢀon a
jumper at the relevant temperature
point.
Around 17°C
MIN
Jumper moved from
initial position
- Limiꢀng the maximum
temperature of the system
(MAX)
If the desired temperature must
not go above 23°C, posiꢀon a
jumper at the relevant temperature
point.
Around 23°C
MAX
- Limiꢀng the temperature
range of the system
Jumper moved from
initial position
If the desired temperature must be
between 17°C and 23°C, posiꢀon
the two jumpers at the relevant
temperature points.
Temperature
setting range :
17°C to 23°C
2
| General | Details |
|---|---|
| Name | NEOMITIS Rtaneoa Wired Analog Room Thermostat Instruction Manual |
| Make | NEOMITIS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.9 MB |

NEOMITIS RTE7OTA Wired Digital 7 Day Programmable Smart Room Thermostat Instruction Manual

Neomitis RTMA Mechanical Room Thermostat Instruction Manual

NEOMITIS RTE7D, RTE7BD Wired Digital 7 Day Programmable Room Thermostat Instruction Manual

NEOMITIS PRG7 RF 7 Day Two Channel Programmer with RF Room Thermostat Instruction Manual

NEOMITIS RTE7SD Mains Powered Digital 7 Day Programmable Room Thermostat Instruction Manual

NEOMITIS RTE0RFA Wireless Digital Room Thermostat and Receiver Instruction Manual

NEOMITIS RTE0B Wired Digital Room Thermostat Installation Guide

NEOMITIS RTUa Mechanical Room Thermostat Instruction Manual