Micro-Air 351 Air Conditioner Digital Thermostat User Guide
EasyTouch RV 351
Max Wi-Fi Recovery
This button on the Wi-Fi settings page, when enabled, will restart the thermostat if it
detects an outage for too long. This is intended to make sure the Wi-Fi connection
from the thermostat stays up as much as possible.
ENABLED
Max Wifi Recovery
Sometimes, a cooling or heating cycle may terminate to accommodate this
functionality. If this is undesirable, it is recommended to turn this feature off while at
the space and reenable it when you plan to be away.
Home/Away
This setting changes from a home memorized set of settings to an away memorized
set of settings. It is like having two different displays, one while you are at the RV and
one for when you are not. Each can be set with a completely different set of modes,
schedules, set points and fan speeds to customize the operation with a single button
press.
Home and Away
Buttons
Bluetooth (Account) Password Reset
This screen is used to reset the saved Bluetooth password in the display. This is the
password that must match your EasyTouch RV app account to make remote
connections. Only one account can have access to the display. Use this whenever
you reset the password to your app account to regain remote access to the display.
Bluetooth
Password Reset
Temperature Reading Adjustment
This setting allows you to calibrate the Inside temperature reading with an offset. For
example, if the inside temperature reads 72F (22.2C) and you feel it is 75F (24C), you
can use the up and down arrows on this page to increment the offset to +3F (+1.8C).
Temperature
Reading
Adjustment
Temperature Gap (Hysteresis)
This setting determines the difference in temperature required between setpoint and
inside temperature before a heating or cooling cycle will begin. This is helpful to
prevent short cycling in large spaces or spaces with high thermal loss, by running a
cycle for longer amounts of time. This offset is applied to all logic that involves
an operational example.
Temperature Gap
Button
Inside
Temperature
(°F)
Heating
Setpoint (°F)
Heating
Hysteresis
(°F)
System Operation
69
66
65
67
69
None
None
Heating Cycle Begins
Heating Cycle Continues
Heating Cycle Ends
68
3
Table 4 - Temperature Gap Operational Example
14
©2024 Micro-Air LLC
Revision 2.0
| General | Details |
|---|---|
| Name | Micro-Air 351 Air Conditioner Digital Thermostat User Guide |
| Make | Micro-Air |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.6 MB |

micro-air EasyTouch 357 Multi Zone Replacement Thermostat Instruction Manual

Micro-Air EasyTouch RV 353 Touch Screen Thermostat Instruction Manual

Micro-Air 359 Touchscreen Thermostat Instruction Manual

Micro-Air EasyTouch RV 353 Thermostat Instruction Manual

micro-Air EasyTouch RV 351 Thermostat User Manual

Micro Air ETRV EasyTouch RV Thermostat Instruction Manual

micro-air EasyTouch RV 356 True Air RV Thermostat User Manual

micro-Air ASY-357-X02 EasyTouch 357 Touchscreen Thermostat User Manual

micro-Air EasyTouch 352 Thermostat User Manual

Micro-Air EasyTouch 355 Touch Screen Thermostat User Manual