Wiring UWP  
Push down on the tabs to put the wires into the inner  
holes of their corresponding terminals on the UWP (one  
wire per terminal) until they are firmly in place. Gently  
tug on the wires to verify they are secure. If you need to  
release the wires again, push down the terminal tabs on  
the sides of the UWP.  
Setting Slider Tabs  
Set R Slider Tab.  
This wiring is just an example,  
yours may vary.  
• Use built-in jumper (R Slider Tab) to  
differentiate between one or two transformer  
systems.  
UWP Mounting System  
• If there is only one R wire, and it is connected  
to the R, Rc, or RH terminal, set the slider to  
the up position (1 wire).  
• If there is one wire connected to the R  
terminal and one wire connected to the Rc  
terminal, set the slider to the down position (2  
wires).  
NOTE: Slider Tabs for U terminals should be left  
in place for other thermostat models.  
R/Rc slider tab  
Wiring terminal designations  
L/A  
- A  
Heat Pump fault input  
(C wire required)  
Input for wired  
indoor or outdoor  
sensors  
S
S
Y
O/B  
Changeover valve  
Compressor  
contactor (stage 1)  
AUX - Auxiliary heat relay  
W2  
Heat relay (stage 2)  
Compressor  
contactor (stage 2)  
Y2  
G
E
Emergency Heat relay  
Heat relay (stage 1)  
Fan Relay  
W
Note: Not all  
terminals may be  
used, depending  
on the system  
type that is being  
wired. The most  
commonly used  
terminals are  
24 VAC common.  
For 2 transformer  
systems, use  
common wire from  
cooling transformer.  
Connect to K on C-wire  
adapter**  
C
K
24 VAC power from  
heating transformer*  
U
U
R
Unused  
24 VAC power from  
cooling transformer*  
shaded.  
Rc  
* Terminal can be jumped using Slider Tab. See “Setting Slider Tabs” above.  
** The THP9045A1098 C-wire adapter is used on heat/cool systems when you  
only have four wires at the thermostat and you need a fifth wire for a common  
wire. Use the K terminal in place of the Y and G terminals on conventional or  
heat pump systems to provide control of the fan and the compressor through  
a single wire—the unused wire then becomes your common wire. See THP9045  
instructions for more information.  
5
GeneralDetails
NameHoneywell TH6320ZW2003 Pro Z-Wave Programmable Thermostat Installation Guide
MakeHoneywell
LanguageEnglish
FiletypePDF (Download)
File size2.34 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Honeywell T6 Pro Programmable Thermostat User Manual
Honeywell T6 Pro Programmable Thermostat User Manual
Honeywell D1-528 Direct Thermostat Installation Guide
Honeywell D1-528 Direct Thermostat Installation Guide
Honeywell FocusPRO P200 Programmable Thermostat User Guide
Honeywell FocusPRO P200 Programmable Thermostat User Guide
Honeywell RCHT8610WF Series Smart Thermostat Installation Guide
Honeywell RCHT8610WF Series Smart Thermostat Installation Guide
Honeywell T9 Smart Thermostat Installation Guide
Honeywell T9 Smart Thermostat Installation Guide
Honeywell TH2320WF4011 FocusPRO Smart S200 Series Thermostat User Guide
Honeywell TH2320WF4011 FocusPRO Smart S200 Series Thermostat User Guide
Honeywell TL116A Thermostat Installation Guide
Honeywell TL116A Thermostat Installation Guide
T10 Pro Smart Thermostat with Redlink Room Sensor
T10 Pro Smart Thermostat with Redlink Room Sensor
Honeywell TH6320WF2003 Lyric T6 Pro Wi-Fi Programmable Thermostat User Guide
Honeywell TH6320WF2003 Lyric T6 Pro Wi-Fi Programmable Thermostat User Guide
Honeywell RTH9580 Wi-Fi Color Touchscreen Programmable Thermostat User Guide
Honeywell RTH9580 Wi-Fi Color Touchscreen Programmable Thermostat User Guide

Honeywell TH6320ZW2003 Pro Z-Wave Programmable Thermostat Installation Guide