Honeywell TH6320ZW2003 Pro Z-Wave Programmable Thermostat Installation Guide
Note: ISU options available may vary upon the thermostat model and equipment setup.
# ISU
ISU Name
ISU Options (defaults in bold)
Notes
120
Schedule Type
No Schedule or Occupancy (when included in Z-Wave network)
MO-SU = Every day the same
You can change default MO-FR, SA-SU schedule here. To edit periods during days, temperature setpoints, or to
turn Schedule On/Off, go to MENU/SCHEDULE (only available if schedule is set).
MO-FR, SA, SU = 5-1-1 schedule
MO-FR, SA-SU = 5-2 schedule
Each Day = Every day individual
125
130
Temp Scale
Fahrenheit, Celsius
Outdoor Temp
No, Wired
An outdoor temperature is required to set the following ISUs: ISU 355 Balance point (Compressor Lockout),
ISU 356 Aux Heat Lockout. Use a wired outdoor sensor connected to the “S” terminals on the UWP and set this
ISU to Wired. ("Wiring heat pump systems" on page 7.)
200
205
System Type
Conventional Forced Air
Heat Pump
Boiler
Basic selection of system your thermostat will control.
Cool Only
Equipment Type
Conventional Forced Air Heat:
Standard Efficiency Gas (STD GAS), High Efficiency Gas (EFF ISU 200 is set to Cool Only.
This option selects the equipment type your thermostat will control. Note: This option is NOT displayed if
GAS), Oil, Electric, Hot Water Fan Coil
Heat Pump:
Air To Air, Geothermal
Boiler:
Hot Water Radiant Heat, Steam
218
220
Reversing Valve
0/B on Cool, 0/B on Heat
This ISU is only displayed if ISU 200 is set to Heat Pump. Select whether reversing valve O/B should energize
on cool or on heat.
Cool Stages
(#200=Conv./
200=HP)
0, 1, 2
221
Heat Stages;
Aux/E Stages
(#200=Conv.;
200=HP)
Heat Stages: 0, 1, 2
AUX/E Stages: 0, 1
Maximum of 2 Heat Stages for conventional systems. Maximum of 1 Aux/E stages for heat pump systems.
This ISU is only displayed if ISU 205 is set to Electric Forced Air or Fan Coil.
230
253
Fan Control
Equipment, Thermostat
Aux/E Control
Both Aux/E, Either Aux/E
Set “EITHER AUX/E” if you want to setup and control of Auxiliary and Emergency heating separately . This ISU
is only displayed if ISU 200 is set to Heat Pump AND if ISU 221 Aux/E stages = 1.
255
Aux Heat Type
Electric, Gas/Oil (or Fossil Forced Air)
This ISU is displayed only if ISU 200 is set to heat pump AND if ISU 221 Aux/E heat stages = 1.
| General | Details |
|---|---|
| Name | Honeywell TH6320ZW2003 Pro Z-Wave Programmable Thermostat Installation Guide |
| Make | Honeywell |
| Language | English |
| Filetype | PDF (Download) |
| File size | 2.34 MB |

Honeywell T6 Pro Programmable Thermostat User Manual

Honeywell D1-528 Direct Thermostat Installation Guide

Honeywell FocusPRO P200 Programmable Thermostat User Guide

Honeywell RCHT8610WF Series Smart Thermostat Installation Guide

Honeywell T9 Smart Thermostat Installation Guide

Honeywell TH2320WF4011 FocusPRO Smart S200 Series Thermostat User Guide

Honeywell TL116A Thermostat Installation Guide

T10 Pro Smart Thermostat with Redlink Room Sensor

Honeywell TH6320WF2003 Lyric T6 Pro Wi-Fi Programmable Thermostat User Guide

Honeywell RTH9580 Wi-Fi Color Touchscreen Programmable Thermostat User Guide