HELTUN Fan Coil Thermostat HE-FT01 User Manual
Z-Wave Plus V2 Specifications
Generic Device Class: GENERIC_TYPE_THERMOSTAT
Specific Device Class: SPECIFIC_TYPE_THERMOSTAT_GENERAL_V2
Supported Command Classes
Command Class
COMMAND_CLASS_ZWAVEPLUS_INFO [0x5E]
COMMAND_CLASS_ASSOCIATION [0x85]
Version
V2
V2
V3
V3
V1
V3
V2
V4
V3
V11
V4
V1
V2
V1
V1
V3
V2
V1
V1
V1
V3
V4
V1
V5
V2
Secure
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
COMMAND_CLASS_ASSOCIATION_GRP_INFO [0x59]
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION [0x8E]
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE [0x42]
COMMAND_CLASS_THERMOSTAT_MODE [0x40]
COMMAND_CLASS_THERMOSTAT_FAN_STATE [0x45]
COMMAND_CLASS_THERMOSTAT_FAN_MODE [0x44]
COMMAND_CLASS_THERMOSTAT_SETPOINT [0x43]
COMMAND_CLASS_SENSOR_MULTILEVEL [0x31]
COMMAND_CLASS_METER [0x32]
COMMAND_CLASS_CLOCK [0x81]
COMMAND_CLASS_TRANSPORT_SERVICE [0x55]
COMMAND_CLASS_SECURITY [0x98]
COMMAND_CLASS_SECURITY_2 [0x9F]
COMMAND_CLASS_VERSION [0x86]
COMMAND_CLASS_MANUFACTURER_SPECIFIC [0x72]
COMMAND_CLASS_DEVICE_RESET_LOCALLY [0x5A]
COMMAND_CLASS_POWERLEVEL [0x73]
COMMAND_CLASS_SUPERVISION [0x6C]
COMMAND_CLASS_INDICATOR [0x87]
COMMAND_CLASS_CONFIGURATION [0x70]
COMMAND_CLASS_APPLICATION_STATUS [0x22]
COMMAND_CLASS_FIRMWARE_UPDATE_MD [0x7A]
COMMAND_CLASS_BASIC [0x20]
YES
YES
YES
YES
YES
YES
YES
YES
Meter Command Class:
Meter Type
Electric [0x01]
Electric [0x01]
Scale
Electric_kWh [0x00]
Electric_W [0x02]
Rate Type
Import [0x01]
Import [0x01]
Precision
Size
4
2
2
0
Thermostat Settings Using Z-Wave Protocol (Gateway)
All configuration parameters are accessed through COMMAND_CLASS_CONFIGURATION
Parameters 01 – 11, 14 – same with the device Settings Menu (see parameter list for details)
Parameters 12, 13, 15 ... 30 – reserved by the manufacturer
Parameter 31 – Sensors Consecutive Report Interval
When the device is connected to the Z-Wave gateway (controller), it periodically sends the gateway reports from room
& floor temperature, humidity, and light sensors even if there are not changes in those values. This Parameter defines
the interval between consecutive reports. The value can be adjusted from 1 min to 120 min. The factory default value
is 10 min.
Note: If the sensor readings change, the device will send the report to the gateway regardless of this parameter value.
In order not to increase traffic on your network, it is not recommended to reduce the value of this parameter. We
recommend reducing the value of this parameter only in cases of poor connection, when reports from the device do
not always reach the gateway.
Parameter 32 – Energy Consumption Meter Consecutive Report Interval
This Parameter defines the interval between consecutive reports of real time and cumulative energy consumption data
to the gateway. The value can be adjusted from 1 min to 120 min. The factory default value is 10 min.
Note: If the sensor readings change, the device will send the report to the gateway regardless of this parameter value.
In order to not increase traffic on your network, we recommend not reducing this value.