At Auto Medium speed, the thermostat will run at Low speed if the Set Point and room temperatures difference is  
less than 1.0°C, and Medium speed if the Set Point and ambient temperatures difference is higher 1.0C.  
At Auto High speed mode, the thermostat will run at Low speed if the Set Point and room temperatures difference is  
less than 1.0°C. It will run Medium speed if the Set Point and room temperatures difference is higher than 1.0°C but  
less then 2.0°C. And it will run on High speed if the Set Point and room temperatures difference is higher than 2.0°C.  
If the Fan Speed selected is OFF, the thermostat will go to IDLE mode (all outputs will be Off).  
Note: depending on speed level, only one output from the group OUT-1, OUT-2, or OUT-3 will be ON.  
Operating Modes  
The HE-FT01 thermostat has Four Operating Modes as follows:  
COM Comfort Mode  
TIME Time Mode (enables different scheduled temperature Set Points per time and day)  
ECO Economy Mode (for power efficient & energy savings)  
OFF – Operating modes disabled  
You may change Modes by touching the “MODE” button (bottom right of LCD) until the desired Mode is reached.  
Each Operating Mode has individual temperature Set Points for each Climate Mode (Heating & Cooling Modes). The  
HE-FT01 will operate automatically depending on the current Set Point indicated under the “SET TEMP” label on the  
LCD. To change the Set Point value, choose the desired Operating Mode (COM, TIME or ECO), choose the Climate  
Mode (“Heating”, “Cooling” or “Heating & Cooling”) and press the Plus “+” button to increase, or Minus “” button to  
decrease, the corresponded Set Point value. You may alternatively control Set Points for each Operating and Climate  
Mode through your Z-Wave gateway software.  
COM - Comfort Mode  
This mode is recommended for maximum comfort. Under this Operating Mode there are three different Climate control  
modes: “Heating”, “Cooling” and “Heating & Cooling.” And each Climate Mode has its own individual Set Point.  
Choose the desired climate mode and adjust the temperature Set Point for each mode separately.  
Note: In your Z-Wave gateway you will see three Set Points corresponding to different climate modes: “Auto  
Changeover” in Z-Wave corresponds to “Heating & Cooling” climate mode in the HE-FT01, “Heat” corresponds to  
Heating” climate mode, and “Cool” corresponds to “Cooling” climate mode.  
Note: Ventilation” Climate Mode will disable (Switch Off) all Operating Modes including COM.  
TIME - Temperature Schedule Mode (Auto)  
The Temperature Schedule (TIME) Mode can adjust home  
temperatures automatically to align with your personal habits, saving  
energy while you are away, and maintaining a comfortable temperature  
while you are active at home.  
The HE-FT01 can have different Schedules for Morning, Daytime,  
Evening and Night. For example, the “Morning” Schedule could be set to  
25.0°C (77°F) starting at 7:00. The “Day” Schedule could then be set to  
11.0°C (or 52°F) at 9:00 when everyone has gone to work or school,  
and so on. Here are recommended Scheduled Set Points for heating  
during the work week – you may wish to change these on weekends depending on your family’s schedule (see  
example below):  
Schedule  
Mode  
Morning  
Day  
Evening  
Night  
Set  
Time  
6:00  
9:00  
18:00  
23:00  
Set Point  
Temperature  
24.0°C (75°F)  
20.0°C (68°F)  
23.0°C (73°F)  
18.0°C (64°F)  
To set up the time and temperature for each Schedule press and hold the Clock “ ” button for three seconds.  
The display will then change to the Time menu.  
8
GeneralDetails
NameHELTUN Fan Coil Thermostat HE-FT01 User Manual
MakeHELTUN
LanguageEnglish
FiletypePDF (Download)
File size0.35 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
HELTUN HE-HT01 Heating Thermostat User Guide
HELTUN HE-HT01 Heating Thermostat User Guide

HELTUN Fan Coil Thermostat HE-FT01 User Manual