- 1. Room Thermostat (Installation And Operation Guide)
- 2. Installation Instructions (Factory Default Settings → Specifications → Lcd Display → Buttons → Wiring → Operating Instructions)
- 3. Adjust The Program Setting In 5/2 Day Mode (Temporary Override / Permanent Override → Boost Function → Menu Function → P0 1 Operating Mode → P0 2 Setting High & Low Limits → P0 4 Calibrate)
- 4. Mains Operated Programmable Room Thermostat (Installation Instructions)
- 5. Factory Default Settings (High And Low Temp Limitation: → Keypad Lock: → Operating Mode: → Temperature Indicator: → Frost Protection: → Daylight Saving Time (dst):)
- 6. Specifications (Contacts → Power Supply / Input → Power Consumption → Temperature Range → Dimensions → Ip Rating)
- 7. Lcd Display (Displays Current Room Temperature. → Displays Current Day Of The Week. → Displays Current / Target Temperature. → Displays When The Thermostat Is Calling For Heat. → Displays Current Time And Date. → Displays Current Operating Mode.)
- 8. Buttons (Reset Button → Menu Button → Ok Button → Time +1h → Down Button → Up Button)
- 9. Wiring (Terminal Connections → Neutral In → Live In → N/c Normally Closed Connection → Common Connection → N/o Normally Open Connection)
- 10. Mounting & Installation (Caution! → Installation And Connection → Qualified Person → Thermostat Usage → Required Settings)
- 11. Remove The Thermostat From Its Packaging (Choose A Mounting Location → Wire The Thermostat According To The Diagram → Screw The Backplate Onto A Back Box → Close The Front Housing And Tighten The Fastening Screw)
- 12.
- 13. Mains Operated Programmable Room Thermostat (Operating Instructions)
- 14. Adjusting The Target Temperature (Locking The Keypad)
- 15. Backlight (Auto → Off → On)
- 16. Auto (Mode Selection)
- 17. Setting The Date, Time & Programming Mode (Holiday Mode)
- 18. How Your Programmable Thermostat Works (Auto Mode Operation → Programming Options → Setting Temperatures → Turning The Thermostat Off)
- 19. Factory Program Setting (/2 Day → Day → Hour)
- 20. Programming Modes (/2 Day Mode → Day Mode → Hour Mode)
- 21. Adjust The Program Setting In 5/2 Day Mode (Programming For Monday To Friday → Programming For Saturday To Sunday → Adjust The P1 Time → Adjust The P1 Temperature → Return To Automatic Mode)
- 22. Temporary Override (Permanent Override)
- 23. Boost Function
- 24. Menu Function (Operating Mode (normal / Optimum Start / Tpi))
- 25. Normal Mode (nor) (Graph (23.1): Normal Mode (on / Off Control))
- 26. P01 Operating Mode (Optimum Start Control (os) → Room Temperature (rt) → Setpoint Temperature (st) → Target Temperature Difference (ttd) → Optimum Start Time (ost))
- 27. Optimum Start Control Graph With Ti = 20 (Optimum Start Control Graph With Ti = 15 → Optimum Start Control Graph With Ti = 10 → Example When Ti = 20 → Example When Ti = 10 → Target Temperature Difference C → Ttd)
- 28. Operating Mode (Time Proportional Integral Mode (tpi) → Cyc Number Of Heating Cycles Per Hour)
- 29. Pb - Proportional Bandwidth (Tpi Control)
- 30. Operating Mode (Time Proportional Integral Mode (tpi) → Use)
- 31. Setting High & Low Limits (Hi 35c Lo 5c → Limit)
- 32. Hysteresis Hon & Hoff (This Menu Allows The Installer To Change The Switching Differential Of The Thermostat When The Temperature Is Rising And Falling.)
- 33. Use & To Select The Hon Temperature, Press To Confirm. Hoff Will Appear On The Screen And The Differential Temperature Will Begin To Flash.
- 34. P04 Calibrate
- 35. Resetting The Thermostat
- 36. Eph Controls Ie (Eph Controls Uk)
×
EPH CDTP2 Room Thermostat Installation Guide
Pb -Proportional Bandwith
2°C
This value refers to the temperature below the target at which
the thermostat will start to operate in TPI control. You can set
this temperature from 1.5°C to 3.0°C in 0.1°C increments.
Graph (27.1): TPI Control
Temp
22˚C
Target Temperature
21˚C
20˚C
Proportional Bandwidth
19˚C
18˚C
17˚C
Time Minutes
0
20
40
60
80
100
Heating On
Heating Oꢀ
EPH Controls Ltd.
27
| General | Details |
|---|---|
| Name | EPH CDTP2 Room Thermostat Installation Guide |
| Make | EPH |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.58 MB |


EUROTRONIC SPIRIT ZigBee Energy Saving Thermostat User Guide

SIEMENS RDH100RF/SET Room Thermostat Instruction Manual

Hansgrohe 13125000 Ecostat E Wall Mounted Shower Thermostat Instruction Manual

STELPRO STF362NP Floor Heating Thermostat Owner’s Manual

GENERAL LIFE FH104 Underfloor Heating Thermostat User Manual

GENERAL LIFE FH250S Floor Heating Thermostat User Manual

sygonix 2522212 Installable Thermostat Instruction Manual

SILVERCREST IAN 469312_2310 Digital Radiator Thermostat Instruction Manual

fastwarm 16AMP Touchscreen Thermostat Instruction Manual

QC Manufacturing Inc IT-30003 Attic Fan Adjustable Thermostat User Manual
Table of Contents
- 1. Room Thermostat - Installation And Operation Guide →
- 2. Installation Instructions - Factory Default Settings →
- 3. Adjust The Program Setting In 5/2 Day Mode - Temporary Overr... →
- 4. Mains Operated Programmable Room Thermostat - Installation I... →
- 5. Factory Default Settings - High And Low Temp Limitation: →
- 6. Specifications - Contacts →
- 7. Lcd Display - Displays Current Room Temperature. →
- 8. Buttons - Reset Button →
- 9. Wiring - Terminal Connections →
- 10. Mounting & Installation - Caution! →
- 11. Remove The Thermostat From Its Packaging - Choose A Mounting... →
- 12. Page 12 →
- 13. Mains Operated Programmable Room Thermostat - Operating Inst... →
- 14. Adjusting The Target Temperature - Locking The Keypad →
- 15. Backlight - Auto →
- 16. Auto - Mode Selection →
- 17. Setting The Date, Time & Programming Mode - Holiday Mode →
- 18. How Your Programmable Thermostat Works - Auto Mode Operation →
- 19. Factory Program Setting - /2 Day →
- 20. Programming Modes - /2 Day Mode →
- 21. Adjust The Program Setting In 5/2 Day Mode - Programming For... →
- 22. Temporary Override - Permanent Override →
- 23. Boost Function →
- 24. Menu Function - Operating Mode (normal / Optimum Start / Tpi... →
- 25. Normal Mode (nor) - Graph (23.1): Normal Mode (on / Off Cont... →
- 26. P01 Operating Mode - Optimum Start Control (os) →
- 27. Optimum Start Control Graph With Ti = 20 - Optimum Start Con... →
- 28. Operating Mode - Time Proportional Integral Mode (tpi) →
- 29. Pb - Proportional Bandwidth - Tpi Control →
- 30. Operating Mode - Time Proportional Integral Mode (tpi) →
- 31. Setting High & Low Limits - Hi 35c Lo 5c →
- 32. Hysteresis Hon & Hoff - This Menu Allows The Installer To Ch... →
- 33. Use & To Select The Hon Temperature, Press To Confirm. Hoff ... →
- 34. P04 Calibrate →
- 35. Resetting The Thermostat →
- 36. Eph Controls Ie - Eph Controls Uk →