1F86-0244
Non-Programmable
APPLICATIONS
1F86-0244 Thermostat
For use with the following Class II systems:
•
•
Single Stage systems
Single-stage heat pump systems with no Aux heat
DO NOT USE WITH:
•
•
Systems exceeding 30 VAC and 1.5 amps
3-wire zoned hydronic heating systems
SPECIFICATIONS
Electrical Rating:
Battery Power................................................. mV to 30 VAC, 50/60 Hz or DC
Input-Hardwire................................................ 20 to 30 VAC
Terminal Load........................................................ 1.0 A per terminal, 1.5A maximum all terminals combined
Setpoint Range...................................................... 45° to 90°F (7° to 32°C)
Differential (Single Stage)...................................... Heat 0.6°F; Cool 1.2°F (adjustable)
Differential (Heat Pump)........................................ Heat 1.2°F; Cool 1.2°F (adjustable)
Operating Ambient................................................. 32° to +105°F (0° to +41°C)
Operating Humidity................................................ 90% non-condensing max.
Shipping Temperature Range................................ -40° to +150°F (-40° to +65°C)
Dimensions Thermostat......................................... 3-3/4” H x 4-3/4” W x 1-1/2” D
PRECAUTIONS
This thermostat is intended for use with a low voltage NEC
WARNING
!
Class II system. Do not use this thermostat with a line voltage
system. If in doubt about whether your wiring is millivolt, line,
or low voltage, have it inspected by a qualified heating and air
conditioning contractor or electrician.
Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could cause
shock or fire hazard.
Do not exceed the specification ratings.
Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will damage
thermostat and could cause personal injury and/or
property damage.
All wiring must conform to local and national electrical codes
and ordinances.
This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could
cause the control to malfunction.
Thermostat installation and all components of the
system shall conform to Class II (current limited)
circuits per the NEC code. Failure to do so could cause
a fire hazard.
CAUTION
!
To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.
PART NO. 37-7010001
Replaces37-7010C
1004
| General | Details |
|---|---|
| Name | COPELAND 1F86-0244 Blue 2 Inch Single Stage Thermostat Instruction Manual |
| Make | Copeland |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.34 MB |

COPELAND 1F95G-1235GC Humidity Universal Thermostat Instruction Manual

COPELAND ST55 Sensi Smart Thermostat Instruction Manual

COPELAND 1F76U-22WFB Series Sensi Lite Smart Thermostat Installation Guide

COPELAND 026-1739 Programmable Touchscreen Thermostat User Manual

COPELAND P-N 810-1600 Programmable Touchscreen Thermostat User Guide