Home > Copeland > COPELAND 1F86-0244 Blue 2 Inch Single Stage Thermostat Instruction Manual

COPELAND 1F86-0244 Blue 2 Inch Single Stage Thermostat Instruction Manual

INSTALLER/CONFIGURATION MENU  
Menu  
Reference  
Number  
Press  
Key  
Displayed  
(Factory  
Default)  
Comments  
Press  
to select from  
listed options  
or  
6
7
8
9
L
(On)  
OFF  
Select Display Light On or OFF  
and  
and  
and  
and  
and  
and  
Temp  
(0 HI)  
4 LO to  
4 HI  
Select temperature display adjustment higher or  
lower  
oF  
oC  
Select oF / oC Display (temperature units in Fahren-  
heit or Celsius)  
Change Filter  
(OFF)  
On  
Select filter replacement indicator OFF or On  
Change Filter  
(200 h)  
25 to 1975  
If Change Filter selected On, selects time interval for  
Change Filter Indicator. (in 25 hour increments)  
10  
Returns to normal operation  
5)฀ Select Compressor Lockout CL OFF or ON - Selecting  
CL On will cause the thermostat to wait 5 minutes between  
cooling cycles. This is intended to help protect the  
compressor from short cycling. Some newer compressors  
already have a time delay built in and do not require this  
feature. Your compressor manufacturer can tell you if the  
lockout feature is already present in their system. When the  
thermostat compressor time delay occurs, it will flash the  
setpoint for up to five minutes.  
1)฀ System Configuration - Selects SS (Single Stage) or HP  
(Heat Pump) operating mode. Default configuration is SS.  
For Heat Pump operation choose HP.  
2)฀ Select CS (Cool Savings™) - With Cool Savings™  
enabled, the thermostat will make small adjustments to  
the Setpoint temperature during periods of high demand  
to reduce cooling system running time and save energy.  
When the cooling system has been running for more than  
20 minutes, humidity in the home will be lower and a higher  
setpoint temperature will feel comfortable. After 20 minutes  
of run time, the thermostat will start increasing the setpoint  
temperature in steps of less than one degree as the system  
continues to run. These adjustments will eventually cause  
the system to satisfy the thermostat and turn the system off  
to reduce the energy consumption. When the Cool Savings  
feature is active and making adjustments, the display will  
show “Save”.The amount of the adjustments to the setpoint  
temperature is dependent on the Cool Savings value that  
is set, 1 being the least adjustment and 6 being the most  
adjustment. With this feature set to OFF, no change will  
occur when the cooling system is continuously running  
during the periods of high demand. Periods of high demand  
will normally occur during the late afternoon and early  
evening on the hottest days of the summer.  
6)฀ Select Backlight Display - The display backlight improves  
display contrast in low lighting conditions. When the “C”  
terminal is connected, selecting backlight CdL On will keep  
the light on continuously. Select backlight OFF will turn the  
light on momentarily when any key is pressed. When the  
“C” terminal is not connected, regardless of the backlight  
selection, the light will be on momentarily when any key is  
pressed.  
7)฀ Select Temperature Display Adjustment 4 LO to 4 HI -  
Allows you to adjust the room temperature display up to 4°  
higher or lower. Your thermostat was accurately calibrated  
at the factory but you have the option to change the display  
temperature to match your previous thermostat. The  
current or adjusted room temperature will be displayed on  
the display.  
3 & 4) Select Cycle Rate Selection - The factory default  
setting for Single Stage Heat is Medium Cycle (ME). For  
Single Stage Cool the default setting is fast (FA).To change  
8)฀ Select F° or C° Readout - Changes the display readout to  
Celsius or Fahrenheit as required.  
9) Select Filter Replacement Reminder and Set Run Time  
Select the “Change Filter” reminder On or OFF. If selected  
cycle rate, press the  
and  
buttons.  
The cycle rate differentials for different settings are:  
On, press  
and  
to select the time period from 25 to  
1975 hours in 25 hour increments. In a typical application,  
200 hours (default) of run time is approximately 30 days.  
After the selected time of blower operation, the thermostat  
will display “Change Filter” as a reminder to change or  
clean your air filter. When “Change Filter” is displayed,  
MODE  
Fast  
Medium Slow  
(ME)฀ (SL)  
0.8°F฀ 1.2°F  
-฀ 1.7°F  
(FA)฀  
SS Heat฀  
SS Cool฀  
0.6°F฀  
1.2°F฀  
press the  
and  
button to clear the display and  
restart the time to the next filter change. A selection of OFF  
will cancel this feature.  
5
GeneralDetails
NameCOPELAND 1F86-0244 Blue 2 Inch Single Stage Thermostat Instruction Manual
MakeCopeland
LanguageEnglish
FiletypePDF (Download)
File size0.34 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
COPELAND 1F95G-1235GC Humidity Universal Thermostat Instruction Manual
COPELAND 1F95G-1235GC Humidity Universal Thermostat Instruction Manual
COPELAND ST55 Sensi Smart Thermostat Instruction Manual
COPELAND ST55 Sensi Smart Thermostat Instruction Manual
COPELAND 1F76U-22WFB Series Sensi Lite Smart Thermostat Installation Guide
COPELAND 1F76U-22WFB Series Sensi Lite Smart Thermostat Installation Guide
COPELAND 026-1739 Programmable Touchscreen Thermostat User Manual
COPELAND 026-1739 Programmable Touchscreen Thermostat User Manual
COPELAND P-N 810-1600 Programmable Touchscreen Thermostat User Guide
COPELAND P-N 810-1600 Programmable Touchscreen Thermostat User Guide

COPELAND 1F86-0244 Blue 2 Inch Single Stage Thermostat Instruction Manual