TROUBLESHOOTING  
Reset Operation  
If a voltage spike or static discharge blanks out the display  
or causes erratic thermostat operation, you may need to  
reset the thermostat. To reset, the System Switch must be  
for approximately 10 seconds until the display goes blank. If  
the thermostat has power, has been reset and still does not  
function correctly contact your heating/cooling service person  
or place of purchase.  
in Cool or Heat. Simultaneously press  
and  
buttons  
Symptom  
Possible Cause  
Corrective Action  
No Heat/No Cool/No Fan  
common problems)  
1. Blown fuse or tripped circuit breaker.  
2. Furnace power switch to OFF.  
Replace fuse or reset breaker.  
Turn switch to ON.  
3. Furnace blower compartment door or  
panel loose or not properly installed.  
Replace door panel in proper position to engage safety  
interlock or door switch.  
No Heat  
1. System Switch not set to Heat.  
Set System Switch to Heat and raise setpoint above room  
temperature.  
2. Loos connection to thermostat or  
system  
Verify thermostat and system wires are securely at-  
tached.  
3. Heating System requires service or  
thermostat requires replacement.  
Diagnostic: Set System Switch to Heat and raise the set-  
point above room temperature. Within a five minutes the  
thermostat should make a soft slick sound. This sound  
usually indicates the thermostat is operating properly.  
If the thermostat does not click, try the reset operation  
listed above. If the thermostat does not click after being  
reset contact your heating and cooling service person  
or place of purchase for a replacement. If the thermostat  
clicks, contact the furnace manufacturer or a service per-  
son to verify the heating system is operating correctly.  
No Cool  
1. System Switch not set to Cool.  
Set System Switch to Cool and lower setpoint below  
room temperature.  
2. Loose connection to thermostat or  
system.  
Verify thermostat and system wires are securely at-  
tached.  
3. Cooling System requires service or  
thermostat requires replacement  
Same procedures as diagnostic for No Heat condition  
except set the thermostat to Cool and lower the setpoint  
below the room temperature. There may be up to a five  
minute delay before the thermostat clicks in Cooling if the  
compressor lock-out option is selected in the configura-  
tion menu (Item 5).  
Heat, Cool or Fan Runs  
Constantly  
1. Possible short in wiring.  
2. Possible short in thermostat.  
3. Possible short in Heat/Cool/Fan  
system.  
Check each wire connection to verify they are not shorted  
or touching together. No bare wire should stick out from  
under terminal screws. Try resetting the thermostat as de-  
scribed below. If the condition persists, the manufacturer  
of your system or service person can instruct you on how  
to test the Heat/Cool/ system for correct operation. If the  
system operates correctly, replace the thermostat.  
4. Fan Switch set to Fan On.  
Furnace Cycles Too Fast 1. The location of the thermostat and/or  
Item 3 (CR Heat) or 4 (CR Cool) in the Configuration  
Menu is the adjustment that controls the cycle rate. If an  
acceptable cycle rate is not achieved using the FA (Fast)  
or SL (Slow) adjustment contact a local service person  
for additional suggestions.  
or Too Slow Cooling  
Cycles Too Fast or Too  
Slow (narrow or wide  
temperature swing)  
the size of the Heating or Cooling  
System may be influencing the cycle  
rate.  
Thermostat Setting and  
Thermometer Disagree  
1. Thermostat thermometer setting  
requires adjustment.  
The thermometer can be adjusted +/- degrees as listed in  
item 7 of the Configuration Menu. No other adjustment is  
possible.  
Blank Display and/or  
Keypad Not Responding  
1. Voltage Spike or Static Discharge.  
If a voltage spike or static discharge occurs use the Reset  
Operation listed above.  
7
GeneralDetails
NameCOPELAND 1F86-0244 Blue 2 Inch Single Stage Thermostat Instruction Manual
MakeCopeland
LanguageEnglish
FiletypePDF (Download)
File size0.34 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
COPELAND 1F95G-1235GC Humidity Universal Thermostat Instruction Manual
COPELAND 1F95G-1235GC Humidity Universal Thermostat Instruction Manual
COPELAND ST55 Sensi Smart Thermostat Instruction Manual
COPELAND ST55 Sensi Smart Thermostat Instruction Manual
COPELAND 1F76U-22WFB Series Sensi Lite Smart Thermostat Installation Guide
COPELAND 1F76U-22WFB Series Sensi Lite Smart Thermostat Installation Guide
COPELAND 026-1739 Programmable Touchscreen Thermostat User Manual
COPELAND 026-1739 Programmable Touchscreen Thermostat User Manual
COPELAND P-N 810-1600 Programmable Touchscreen Thermostat User Guide
COPELAND P-N 810-1600 Programmable Touchscreen Thermostat User Guide

COPELAND 1F86-0244 Blue 2 Inch Single Stage Thermostat Instruction Manual