Zehnder ComfoControl Ease Installation Guide
5.2 P menus
The ComfoAir installer manual states
which functions are supported. This
manual will also mention the effects of the
different functions.
Not all functions are supported by every
ComfoAir.
This might result in certain P menus not
being visible. It is also possible that some
changes you enter appear to have no
effect.
P menus for the user.
Menu P1 Status of programmes
Status
Sub-menu
P10
Description
Activated
Is menu 20 currently active?
Is menu 21 currently active?
Is menu 22 currently active?
Is menu 23 currently active?
Is menu 24 currently active?
Is menu 25 currently active?
Is menu 26 currently active?
Is menu 29 currently active?
Yes (1) / No (0)
Yes (1) / No (0)
Yes (1) / No (0)
Yes (1) / No (0)
Yes (1) / No (0)
Yes (1) / No (0)
Yes (1) / No (0)
Yes (1) / No (0)
P11
P12
P13
P14
P15
P16
P19
Menu P2 Setting time delays
Time delay values
Sub-menu
Description
Minimum Maximum Factory reset
P20
n/a
0 Min.
0 Min.
180 Min.
15 Min.
0 Min.
0 Min.
P21
Activation delay for the bathroom
switch (to switch to high setting).
(Optional)
■
“x” minutes after operating the
bathroom switch, the ComfoAir
switches to the high setting.
Note:
Only applies to systems
fitted with a corded
switch and a second
switch in the bathroom.
- Low voltage input
P22
Deactivation delay for the bathroom
switch (to switch to normal setting).
0 Min.
120 Min.
30 Min.
(Optional)
■
“x” minutes after operating the
bathroom switch, the ComfoAir
switches to the normal setting.
Note:
Only applies to systems
fitted with a corded
switch and a second
switch in the bathroom.
- Low voltage input
P23
n/a
0 Min.
120 Min.
0 Min.
EN - 15
| General | Details |
|---|---|
| Name | Zehnder ComfoControl Ease Installation Guide |
| Make | Zehnder |
| Language | English |
| Filetype | PDF (Download) |
| File size | 1.37 MB |