Malfunction alerts  
Meanings of malfunction alerts  
Alerts of possible malfunctions can be  
found in the ComfoAir’s manual.  
Code  
A0  
Description  
n/a  
The system should remain connected  
to its power supply unless the ComfoAir  
requires taking out of service due to a  
serious malfunction or for filter cleaning/  
replacement or any other compelling  
reasons. When the unit is disconnected,  
the dwelling will no longer enjoy  
A1  
NTC sensor T1 is defective.  
(= outside air temperature)  
A2  
A3  
A4  
NTC sensor T2 is defective.  
(= supply air temperature)  
NTC sensor T3 is defective.  
( =return air temperature)  
NTC sensor T4 is defective.  
(= exhaust air temperature)  
A5  
Malfunction in the bypass motor.  
mechanical ventilation, and this can lead  
to problems with damp and mould. Long-  
term deactivation of the ComfoAir must be  
prevented.  
A6  
n/a  
n/a  
A10  
A11  
NTC sensor Tah is defective.  
(= temperature of the Post-heater)  
E1  
E2  
E4  
Exhaust fan not rotating.  
Supply fan not rotating.  
The ComfoAir has been switched off by  
external contact.  
EA1  
EA2  
NC  
Enthalpy sensor measures excessive  
Relative Humidity (RH) values.  
The ComfoAir is not  
communicating with the enthalpy sensor.  
CC Ease is not communicating with the  
ComfoAir.  
FilterI  
Internal Filter is dirty.  
FilterE External Filter is dirty.  