Home > Zehnder > Zehnder ComfoControl Ease Installation Guide

Zehnder ComfoControl Ease Installation Guide

Menu P5 Setting additional programmes  
Additional programme values  
Sub-menu  
Description  
Minimum Maximum Factory reset  
P50  
Activation of the  
0 (= No)  
1 (= Yes)  
0
open fire programme.  
P51  
P52  
n/a  
n/a  
0 (= No)  
1 (= Yes)  
0
0
3
2
P53  
P54  
n/a  
0 (= No)  
0 (= No)  
1 (= Yes)  
1 (= Yes)  
0
1
Confirming the presence of a bypass.  
The standard ComfoAir configuration includes a bypass.  
Leave the value at “1”.  
P55  
Confirming the presence of a Post-heater.  
0 (= No)  
1 (= Yes)  
0
(Optional)  
0; Post-heater not fitted.  
1; Post-heater fitted.  
2; Post-heater is fitted and is regulated by a Pulse.  
Width Modulation (PWM) signal.  
P56  
P57  
P58  
Setting the required  
nL  
HL  
HL  
air volume in the house.  
nL: “normal air volume”.  
HL: “high air volume”.  
Note:  
Setting the air volume is the starting point for programming the air specifications and setting the  
fans.  
Setting the ComfoAir type.  
Li  
Re  
Li  
Li = “Left-hand version”.  
Re = “Right-hand version”.  
Note:  
The ComfoAir is correctly preprogrammed at the factory.  
This setting is lost during a factory reset and will then have to be reprogrammed.  
The correct setting can be found on the ComfoAir's identification plate.  
Enter controller priorities.  
0
1
0
0; In the AUTO mode the signals of the analogue  
(0-10V) ports are included when defining the high  
setting.  
1; In the AUTO mode the signals of the analogue  
(0-10V) ports are ignored when defining the high  
setting.  
Note:  
In the MANUAL mode all signals are always included when defining the high setting.  
P59  
Confirming the presence of an enthalpy exchanger.  
0 (= No)  
2 (= Yes)  
0
(Optional)  
0; Enthalpy exchanger fitted  
1; Enthalpy exchanger with RH sensor.  
2; Enthalpy exchanger without RH sensor.  
If an enthalpy exchanger without a sensor is selected, then the protection programme will  
not be activated and malfunction alerts EA1 & EA2 will never occur.  