Zehnder ComfoControl Ease Installation Guide
5. Commissioning
5.1 Use of the ComfoControl Ease
The overview below summarizes the information that will be displayed on the CC Ease.
Time and date
Supply air
or exhaust air
ON or OFF
Ventilation programme
(AUTO) or manual
ventilation (MANUAL)
bypass
activated
Signal to replace
internal (I) or external (E)
filter
Actual ventilation setting
Comfort temperature or
temporary high setting,
analogue programme active
The CC Ease has a number of buttons to operate the ComfoAir and to enter the settings.
These buttons are illustrated below.
This button switches to the highest ventilation setting.
- Press once Boost setting ON.
- Press twice Boost setting OFF.
This button allows you to switch between supply/exhaust.
- Press once SUPPLY OFF (and EXHAUST ON).
- Press twice EXHAUST OFF (and SUPPLY ON).
- Press 3 times SUPPLY and EXHAUST both ON.
This button allows you to display or set the comfort temperature.
- Press for less than 2 seconds READ.
- Press for longer than 2 seconds SET.
This button allows you to adjust two settings.
- Press for less than 2 seconds Programme ventilation setting (AUTO / MANUAL).
- Press for longer than 2 seconds Set date and time.
These buttons allow you to adjust various settings:
- In P menu or comfort temperature screen Set values.
- In main screen enter ventilation setting (A, 1, 2, 3).
While the open fire programme is
activated the supply and exhaust
fan cannot be manually switched
off.
Not all CC Ease operating
functions are supported by each
ventilation system.
EN - 7