×
- 1. Comfocontrol Ease (Installer Manual → Heating → Cooling → Fresh Air → Clean Air)
- 2. This Documentation Has Been Compiled With The Utmost Care. The Publisher Cannot Be Held Liable For Any Damage Caused As A Result Of Missing …
- 3. Installation Conditions (Checking The Delivery → Transport And Unpacking)
- 4. The System (Wall Mounting → Cabling → Dimension Sketch → Mounting Instructions)
- 5. Commissioning (Use Of The Comfocontrol Ease → Ventilation Programme → Comfort Temperature)
- 6. Setting Additional Ventilation Programmes/options In The P Menus (Reading And Setting The Day And Time → Reading And Setting The Comfort Temperature → Reading And Setting The Ventilation Volume → Activating The Temporary High Setting → Switching The Supply And Exhaust Fan On/off (optional) → Setting A Personal Ventilation Programme)
- 7. Reading And Setting The Comfort Temperature (Reading And Setting The Ventilation Volume)
- 8. Setting The Ventilation Levels (Setting 1 → Setting 2 → Setting 3 → Timer → Setting A → Auto Setting / Manual Setting)
- 9. Temporarily Activating High Setting (Start Temporary → High Setting)
- 10. Switching Supply And Exhaust Fan On/off (optional) (Supply Fan Switched Off → Exhaust Fan Switched Off → Supply And Exhaust Fans Switched On)
- 11. Setting Ventilation Programme (Day Options Are: → Ventilation Profile Stage → Ventilation Setting → Auto Mode? → Selecting Factory Reset Will Reload The Default Ventilation Programme)
- 12. Resetting Malfunctions (Programme Mode → Using P Menus → User P Menu → Installer P Menu → Select P Menu → Select Value)
- 13. P Menus For The User (Menu P1 → Menu P2 → Setting Time Delays)
- 14. Time Delay Values (Description → Filter Warning → Time For The Temporary High Setting)
- 15. Status Of Programmes (Factory Reset → Open Fire Programme Active? → Bypass Open? → Post-heater On? → Analogue Ports (0-10v) Active? → Frost Protection On?)
- 16. Setting Ventilation Programmes (Reading Temperatures)
- 17. Setting Additional Programmes (Additional Programme Values → Confirming The Presence Of A Bypass → Confirming The Presence Of A Post-heater → Setting The Required Air Volume In The House → Setting The Comfoair Type → Enter Controller Priorities)
- 18. Setting Additional Programmes (optional) (Reading Malfunctions (and System Information) → Factory Reset → Malfunction Information Values → Current Software Version → Resetting A Malfunction)
- 19. Self-testing The Comfoair. (Resetting Filter Dirty Counter.)
- 20. Setting The Analogue Ports (0-10v) (Values Of Analogue Port → Sub-menu Description → Factory Reset → Analogue Input 1 → Analogue Input 2 → Analogue Input 3)
- 21. Values Of Analogue Port (Sub-menu Description → Factory Reset)
- 22. Maintenance (Malfunctions → Filter Malfunction)
- 23. Malfunction Alerts (Meanings Of Malfunction Alerts → Alerts Of Possible Malfunctions Can Be → Code → Description)
- 24. Liability (Warranty And Liability → Warranty Conditions → The Warranty Becomes Invalid If:)
- 25. Zehnder America Inc. (Portsmouth Avenue Greenland Nh 03840)
×
Zehnder ComfoControl Ease Installation Guide
Switching supply and exhaust fan on/
off (optional)
While the open fire programme is
activated, the supply and exhaust
fan cannot be manually switched
off.
Bear in mind that switching off
the supply or exhaust fan will
temporarily immobilize your
dwelling’s balanced ventilation
system.
Supply fan switched off
Exhaust fan switched off
Supply and exhaust fans switched on
Switch
supply/exhaust
fan on/off
< 2 sec.
12 - EN
| General | Details |
|---|---|
| Name | Zehnder ComfoControl Ease Installation Guide |
| Make | Zehnder |
| Language | English |
| Filetype | PDF (Download) |
| File size | 1.37 MB |


AprilAire S86W MUPR WiFi Thermostat User Guide

GENERAL FH100 Floor Heating Thermostat User Guide
PURGEAR STC-2303 Digital Thermostat User Guide

Carrier EB-STATE3LTICB-01 lLite Smart Thermostat Instructions

GENERAL Life SENNA 300 RF Wireless Room Thermostat User Guide

NEOMITIS RTE7SD Mains Powered Digital 7 Day Programmable Room Thermostat Instruction Manual

SANGAMO CHPWIFI Fort Programmable Thermostat User Guide

ENGO E901 Programmable Wired Thermostat User Manual

ENGO CONTROLS EFAN-230W Fan Coil Thermostat User Guide

OJ ELECTRONICS MWD5-1999-UAC3 Voice Control Wi-Fi Thermostat Instructions
Table of Contents
- 1. Comfocontrol Ease - Installer Manual →
- 2. This Documentation Has Been Compiled With The Utmost Care. T... →
- 3. Installation Conditions - Checking The Delivery →
- 4. The System - Wall Mounting →
- 5. Commissioning - Use Of The Comfocontrol Ease →
- 6. Setting Additional Ventilation Programmes/options In The P M... →
- 7. Reading And Setting The Comfort Temperature - Reading And Se... →
- 8. Setting The Ventilation Levels - Setting 1 →
- 9. Temporarily Activating High Setting - Start Temporary →
- 10. Switching Supply And Exhaust Fan On/off (optional) - Supply ... →
- 11. Setting Ventilation Programme - Day Options Are: →
- 12. Resetting Malfunctions - Programme Mode →
- 13. P Menus For The User - Menu P1 →
- 14. Time Delay Values - Description →
- 15. Status Of Programmes - Factory Reset →
- 16. Setting Ventilation Programmes - Reading Temperatures →
- 17. Setting Additional Programmes - Additional Programme Values →
- 18. Setting Additional Programmes (optional) - Reading Malfuncti... →
- 19. Self-testing The Comfoair. - Resetting Filter Dirty Counter. →
- 20. Setting The Analogue Ports (0-10v) - Values Of Analogue Port →
- 21. Values Of Analogue Port - Sub-menu Description →
- 22. Maintenance - Malfunctions →
- 23. Malfunction Alerts - Meanings Of Malfunction Alerts →
- 24. Liability - Warranty And Liability →
- 25. Zehnder America Inc. - Portsmouth Avenue Greenland Nh 03840 →






























