WATTS W561 WiFi Thermostat Instruction Manual
Setup - Sensors
Setting
Range
Default
SENSOR 1
Select the type of sensor connected to S1 and Com
wiring terminals.
Off,
Room,
Floor
Off
Off,
Room,
Floor,
SENSOR 2
Select the type of sensor connected to S2 and Com
wiring terminals.
Off
On
Outdoor
INTERNAL ROOM SENSOR
Off,
On
Select if the internal room temperature sensor is on or
off. Only available when Sensor 1 or 2 is set to read a
room or floor sensor.
ROOM OFFSET
Off,
-5 to +5°F
-3.0 to 3.0°C
Select if the internal room temperature sensor is on or
off. Only available when Sensor 1 or 2 is set to read a
room or floor sensor.
Off
Off
Off,
-5 to +5°F
-3.0 to 3.0°C
FLOOR OFFSET
Manual offset correction of the floor temperature
measurement.
Setup - Alerts
Setting
Range
Default
ROOM HOT WARNING
Sends an email notification if the room exceeds this
temperature.
Off, 40 to 100°F
Off, 4.5 to 38.0°C
Off
ROOM COLD WARNING
Sends an email notification if the room falls below this
temperature.
Off, 40 to 100°F
Off, 4.5 to 38.0°C
Off
Setup - Relays
Setting
Range
Default
RADIANT FLOOR HEATING
Select if the first stage W1 heats a radiant floor.
No,
Yes
No
19
| General | Details |
|---|---|
| Name | WATTS W561 WiFi Thermostat Instruction Manual |
| Make | WATTS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.38 MB |

WATTS IOM-T-564 tekmar Invita WiFi Thermostat Instruction Manual

WATTS IOM-T-563 Tekmar WiFi Thermostat Installation Guide

WATTS BT-A03 RF Electronic Room Thermostat Installation Guide

WATTS TEK564 Invita WiFi Thermostat Instruction Manual

WATTS WTC-ES Contact Thermostat User Manual

WATTS 563 WiFi Thermostat User Manual

WATTS Tekmar Wi-Fi Thermostat Instruction Manual