Home > Vive > VIVE TP-S-955WH Programmable Thermostat Instruction Manual

VIVE TP-S-955WH Programmable Thermostat Instruction Manual

Installation Tips  
Installation Tips  
Mount Thermostat and Base Module  
Base Module Subbase installation  
Pro1 Base Module  
for use with T955WH  
H
Temperature  
D
Y1  
Y2  
W1/E  
W2  
G
Clean  
Display  
Humidity  
O
B
Set Time  
Next Zone  
Align the 4 tabs on the subbase with corresponding slots on  
the back of the thermostat/base module, then push gently until  
it snaps in place.  
Note: To ensure a solid fit between the thermostat/base module  
and the subbase:  
1. Mount subbase to a flat wall  
2. Use screws provided  
3. Drywall anchors should be flush with the wall  
4. Wires should be pushed into the wall  
For horizontal mount put one screw on  
Horizontal Mount  
Vertical Mount  
the left and one screw on the right.  
For vertical mount put one screw on  
the top and one screw on the bottom.  
Battery Installation  
Battery installation is optional if there are no remotes  
connected to the Master Thermostat (C terminal con-  
nected). If you connect an outdoor remote and/or  
indoor remote sensors it is required the  
thermostat be hardwired.  
Wiring Note  
Wire the base module’s subbase the same way you would wire a  
hardwired thermostat subase.  
Important: High quality alkaline batteries are  
recommended. Rechargeable batteries or low quality  
batteries do not guarantee a 1-year life span.  
Note:  
To connect the base module to the master thermostat, refer to the  
directions on page 13 of this manual.  
Insert 2 AA Alkaline  
batteries (included). High  
quality alkaline batteries  
are recommended.  
Note:  
On the back of the  
thermostat insert 2  
AA Alkaline batteries  
(included).  
The base module must be hardwired (C and R terminals connected to  
24V power.)  
5
6
Thermostat Quick Reference  
Thermostat Quick Reference  
Getting to know your thermostat  
Getting to know your thermostat  
Mon Tue Wed Thu Fri Sat Sun  
2
8
2
REMOTE  
HOLD  
F C  
7
1
WAKE  
Heat  
Off  
Cool  
Auto  
Em. Heat  
LEAVE  
RETURN  
Temperature  
9
3
Clean  
Display  
Humidity  
11  
+1 +2  
7
13  
SLEEP  
1
Clean  
Display  
Humidity  
Technician  
Setup  
Next Step  
Set Time  
Next Zone  
Set Schedule  
Hold  
Previous Step  
Run Schedule  
Menu  
Done  
Auto  
On  
12  
Set Time  
Next Zone  
Indicates the current room temperature  
Time and day of the week  
1
2
3
1
3
Low Battery Indicator: Replace batterieswhen this indicator is shown.  
Program Menu Options: Show different options during programming.  
Period Icons - This thermostat can have 2 or 4 programmable time periods  
per day. Icons are displayed for 4 time periods. Occupied and unoccupied  
will display in the text field for 2 time periods.  
LCD Display  
1
2
3
REMOTE indicates a remote has control of the system.  
Glow in the dark light button  
Fan key  
7
8
9
HOLD is displayed when thermostat program is permanently overriden.  
Setpoint: Displays the user selectable setpoint temperature  
System key  
System Operation Indicators: The COOL, HEAT or FAN icon will display  
when the COOL, HEAT or FAN is on. NOTE: The compressor delay feature is  
active if these icons are flashing. The compressor will not turn on until the 5  
minute delay has elapsed.  
Setpoint keys  
Menu key  
Humidity: Shows the humidity target setpoint settings and keys.  
1
Scheduled time period Icons  
7
Clean Display: Pressing CLEAN DISPLAY will allow 30 seconds to clean the  
display. The keys will be inoperable during this time. CLEAN will appear if  
your contractor has programmed a filter change reminder. Press CLEAN  
when filter has been replaced to reset the filter change reminder timer.  
11  
Important  
The low battery indicator is displayed when the AA battery power is low. If the user  
fails to replace the battery within 21 days, the screen will only show the low battery  
indicator but maintain all functionality. If the user fails to replace the batteries after  
an additional 21 days (days 22-42 since first “low batterydisplay) the setpoints will  
change to 55˚F (Heating) and 85˚F (Cooling). If the user adjusts the setpoint away from  
either of these, it will hold for 4 hours then return to either 55˚F or 85˚F. After day 63  
the batteries must be replaced immediately to avoid freezing or overheating because  
the thermostat will shut the unit off until the batteries are changed.  
Next Zone: This button will appear if optional indoor remotes are  
present. By selecting NEXT ZONE you can cycle through each of the zones  
set up during the initial installation.  
12  
13  
System Information: Shows which zone or zones are controlling your  
system. Shown only when one or more indoor sensors are connected.  
9
10  
GeneralDetails
NameVIVE TP-S-955WH Programmable Thermostat Instruction Manual
MakeVive
LanguageEnglish
FiletypePDF (Download)
File size0.67 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
VIVE TP-N-751 Programmable Thermostat Installation Guide
VIVE TP-N-751 Programmable Thermostat Installation Guide
VIVE TP-S-855C Digital Programmable Thermostat Instruction Manual
VIVE TP-S-855C Digital Programmable Thermostat Instruction Manual

VIVE TP-S-955WH Programmable Thermostat Instruction Manual