VIVE TP-S-955WH Programmable Thermostat Instruction Manual

Technician Setup  
Technician Setup  
Tech Setup Steps  
LCD Will Show Adjustment Options  
Default Tech Setup Steps  
LCD Will Show Adjustment Options  
Default  
You can select the  
OFF  
1, 2, or 3 hours.  
Use the or key to  
90  
setpoint.  
The pre-occupancy fan settings  
This feature allows you to set a  
Heating  
Temperature  
Setpoint  
Limit  
pre-occupancy fan from OFF,  
select the maximum heat  
will energize the fan before  
the occupied time to provide  
ventilation prior to scheduled  
occupancy.  
This feature only shows if the  
technician setup step for time  
periods is set to 2C or 4C.  
maximum heating setpoint limit.  
The setpoint temperature cannot  
be raised above this value.  
90˚F  
Pre-Occupancy  
Fan  
If 1, 2, or 3 is selected, the  
fan will turn on that many  
hours prior to the scheduled  
occupied time period.  
PRE  
OCCUPY  
FAN  
HE  
OFF  
This feature allows you to set a  
minimum cooling setpoint limit.  
The setpoint temperature cannot  
be lowered below this value.  
Use the or key to  
44  
setpoint.  
Cooling  
Temperature  
Setpoint  
Limit  
select the minimum cool  
44˚F  
˚F  
The display light can be  
configured to stay on all the  
time or come on when any key  
is pressed.  
NOTE: HARDWIRE ONLY  
Keeping the display light  
continually “ON”will greatly  
reduce battery life.  
Use the or key to to  
turn on or off.  
OFF configures the display  
light to come on when the  
light key or any button is  
pressed.  
CO  
This feature allows you to display  
temperatures in either Fahrenheit  
or Celsius.  
˚F for Fahrenheit  
˚C for Celsius  
Display Light  
O
OFF  
˚F or ˚C  
ON configures the display  
light to stay on.  
dL  
F
74  
You can select either a 12 or 24  
hour clock setting.  
Use the or key to  
12H  
12 or 24  
Hour Clock  
select 12 or 24 hour clock.  
12  
Allows you to put your phone  
number in the display.  
If selected ON, you will  
see the input screen after  
pressing NEXT STEP.  
OFF  
HOUR CLOCK  
This feature will start heating  
early to bring the building  
temperature to its programmed  
setpoint by the beginning of the  
WAKE, OCCUPIED time period.  
Use the or key to  
turn on or off.  
Use the  
or key to  
Contractor  
Call Number  
You can choose ON or OFF.  
select the desired number  
and the or key to  
move from one character to  
another. See note below for  
operation.  
OFF  
ON  
Morning  
Recovery  
ON  
5d  
You can configure this thermostat  
to have a 7 day program, a  
5+1+1 program or as  
Use the or key to  
select 7d for 7 day, 5d for  
5+1+1, or 0d for  
nonprogrammable.  
When any key is pressed an  
audible beep will sound.  
If ON is selected the beep  
will sound.  
5d  
Program  
Options  
nonprogrammable.  
If OFF is selected there is no  
sound.  
Beep  
You can choose ON or OFF.  
You can configure this thermostat  
to have 2 or 4 programmable time  
periods per day. 4 time periods  
are Wake, Leave, Return & Sleep.  
2C time periods are Occupied  
& Unoccupied. 4C time periods  
are Occupied 1, Unoccupied 1,  
Occupied 2, & Unoccupied 2.  
Use the  
select 4, 2c, or 4c time periods  
per day.  
or  
key to  
b
4
Time Periods  
4
Contractor Call Number Note  
If contractor call number is selected ON, the phone number entered will  
show in the display if there has been a continuous call for heating or  
cooling for 24 hours or if the light button is held down for 3 seconds. To  
remove the phone number from the display, hold the light button down  
for 3 seconds.  
21  
22  
Technician Setup  
Technician Setup  
Tech Setup Steps  
LCD Will Show Adjustment Options  
Default  
Tech Setup Steps  
LCD Will Show Adjustment Options  
Default  
This feature adds humidity when  
SYSTEM key is in heat.  
You can configure the thermostat  
to operate a 3 stage heat pump  
system.  
2H 2C = 2 heat, 2 cool  
3H 2C = 3 heat, 2 cool  
This feature is shown only if the  
HEAT PUMP technician setup  
step is ON.  
Use the  
turn on of off.  
or  
key to  
Use the or  
key to  
OFF  
2H2C  
change between 2 or 3  
stages of heat. 2 heat will  
use Y1 as first stage and W2  
as auxiliary.  
3 heat will use Y1 as the first  
stage, Y2 as the second stage  
and W2 as the auxiliary.  
If ON is selected the humidity  
will be displayed on the main  
screen and HUM terminal  
will energize when humidity  
setpoint is above ambient  
humidity in Heat mode.  
Stages of  
Heat  
2
Humidify  
STAGES  
See terminal options on following  
page.  
OFF  
OFF  
STAGE  
HUMIDITY  
Requires Outdoor Sensor  
This feature removes humidity  
when SYSTEM key is in cool.  
Use the  
turn on of off.  
or key to  
OFF  
An outdoor temperature  
Use the  
YES or NO.  
or  
to select  
YES  
If ON is selected the humidity  
will be displayed on the main  
screen and DHM terminal  
will energize when humidity  
setpoint is below ambient  
humidity in Cool mode.  
50  
Balance Point  
Temp  
ABOVE this setting will LOCKOUT  
the auxilary heat terminal (W2),  
and ONLY ALLOW the heat pump/  
compressor terminals (Y’s) to  
energize.  
Dehumidify  
See terminal options on following  
page.  
If set to YES then use or  
to select Balance point  
Only shows if Heat  
Pump is turned  
ON and Remote  
Sensor is set to 2.  
DEHUMIDIFY  
BALANCE Temperature of 10, 20, 30,  
35, 40, 45 or 50 degrees.  
An outdoor temperature  
BELOW this setting can perform  
2 different ways, depending on  
the previous Gas Aux/Dual  
Fuel setting.  
This feature allows the installer  
to change the calibration of the  
ambient humidity displayed.  
Use the  
adjust the calibration +/-3.  
or  
key to  
POINT  
0
Humidity  
Calibration  
Requires  
Outdoor Sensor  
0
NO  
3
1= approx. 5%  
HUM  
CALIBRATE  
1. If Gas Aux/Dual Fuel is set OFF  
(Default-typical Electric Aux  
setting) This will allow both heat  
pump (Y’s) and auxiliary heat  
(W2) to run together.  
This feature forces the A/C to run  
longer to remove humidity when  
needed. The A/C will “over cool”  
the room a few degrees until the  
humidity reaches the desired  
setpoint.  
Use the or  
select YES or NO.  
key to  
Dehumidify  
with AC  
If selected Yes, allows over  
cooling to be used to control  
humidity in cool mode. If NO  
is slected the system will not  
use over cooling.  
d HUMIDIFY  
AC  
2. If Gas Aux/Dual Fuel is set ON  
(typical Gas Auxilary/Dual Fuel  
setting) This will LOCKOUT the  
heat pump (Y’s) and ONLY ALLOW  
the auxiliary heat (W2) to energize  
NO  
NO  
The amount of over cooling  
allowed when using A/C to  
remove humidity. This screen is  
only shown when ON is selected  
in the “Dehumidify with AC”tech  
setup step.  
Use the or key to  
select the maximum number  
of degrees of over cool.  
3
Over Cool  
Limit  
Options are: 2, 3, 4, 5 Degrees.  
OVER COOL  
LIMIT  
Balance point run time will allow  
the W2 auxiliary terminal to  
energize even if outdoor  
temperature is above the selected  
balance point temperature.  
If enabled, auxiliary will energize  
for the current cycle after the  
balance point run time has  
expired.  
YES  
15, 30, 45, 60, 75, 90  
continuous run time  
minutes.  
Options for how the HUM  
terminal energizes.  
Use the or key to  
select the one of the four  
options.  
1
Balance  
Point Run  
Time  
HUM  
Terminal  
1
View the HUM terminal chart  
below for an explanation of  
these options.  
BALANCE  
RUNTIME  
HUM  
TERMINAL  
26  
25  
GeneralDetails
NameVIVE TP-S-955WH Programmable Thermostat Instruction Manual
MakeVive
LanguageEnglish
FiletypePDF (Download)
File size0.67 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
VIVE TP-N-751 Programmable Thermostat Installation Guide
VIVE TP-N-751 Programmable Thermostat Installation Guide
VIVE TP-S-855C Digital Programmable Thermostat Instruction Manual
VIVE TP-S-855C Digital Programmable Thermostat Instruction Manual

VIVE TP-S-955WH Programmable Thermostat Instruction Manual