VIVE TP-S-955WH Programmable Thermostat Instruction Manual
Technician Setup
Technician Setup
Tech Setup Steps
LCD Will Show Adjustment Options
Default Tech Setup Steps
LCD Will Show Adjustment Options
Default
You can select the
OFF
1, 2, or 3 hours.
Use the or key to
90
setpoint.
The pre-occupancy fan settings
This feature allows you to set a
Heating
Temperature
Setpoint
Limit
pre-occupancy fan from OFF,
select the maximum heat
will energize the fan before
the occupied time to provide
ventilation prior to scheduled
occupancy.
This feature only shows if the
technician setup step for time
periods is set to 2C or 4C.
maximum heating setpoint limit.
The setpoint temperature cannot
be raised above this value.
90˚F
Pre-Occupancy
Fan
If 1, 2, or 3 is selected, the
fan will turn on that many
hours prior to the scheduled
occupied time period.
PRE
OCCUPY
FAN
HE
OFF
This feature allows you to set a
minimum cooling setpoint limit.
The setpoint temperature cannot
be lowered below this value.
Use the or key to
44
setpoint.
Cooling
Temperature
Setpoint
Limit
select the minimum cool
44˚F
˚F
The display light can be
configured to stay on all the
time or come on when any key
is pressed.
NOTE: HARDWIRE ONLY
Keeping the display light
continually “ON”will greatly
reduce battery life.
Use the or key to to
turn on or off.
OFF configures the display
light to come on when the
light key or any button is
pressed.
CO
This feature allows you to display
temperatures in either Fahrenheit
or Celsius.
˚F for Fahrenheit
˚C for Celsius
Display Light
O
OFF
˚F or ˚C
ON configures the display
light to stay on.
dL
F
74
You can select either a 12 or 24
hour clock setting.
Use the or key to
12H
12 or 24
Hour Clock
select 12 or 24 hour clock.
12
Allows you to put your phone
number in the display.
If selected ON, you will
see the input screen after
pressing NEXT STEP.
OFF
HOUR CLOCK
This feature will start heating
early to bring the building
temperature to its programmed
setpoint by the beginning of the
WAKE, OCCUPIED time period.
Use the or key to
turn on or off.
Use the
or key to
Contractor
Call Number
You can choose ON or OFF.
select the desired number
and the or key to
move from one character to
another. See note below for
operation.
OFF
ON
Morning
Recovery
ON
5d
You can configure this thermostat
to have a 7 day program, a
5+1+1 program or as
Use the or key to
select 7d for 7 day, 5d for
5+1+1, or 0d for
nonprogrammable.
When any key is pressed an
audible beep will sound.
If ON is selected the beep
will sound.
5d
Program
Options
nonprogrammable.
If OFF is selected there is no
sound.
Beep
You can choose ON or OFF.
You can configure this thermostat
to have 2 or 4 programmable time
periods per day. 4 time periods
are Wake, Leave, Return & Sleep.
2C time periods are Occupied
& Unoccupied. 4C time periods
are Occupied 1, Unoccupied 1,
Occupied 2, & Unoccupied 2.
Use the
select 4, 2c, or 4c time periods
per day.
or
key to
b
4
Time Periods
4
Contractor Call Number Note
If contractor call number is selected ON, the phone number entered will
show in the display if there has been a continuous call for heating or
cooling for 24 hours or if the light button is held down for 3 seconds. To
remove the phone number from the display, hold the light button down
for 3 seconds.
21
22
Technician Setup
Technician Setup
Tech Setup Steps
LCD Will Show Adjustment Options
Default
Tech Setup Steps
LCD Will Show Adjustment Options
Default
This feature adds humidity when
SYSTEM key is in heat.
You can configure the thermostat
to operate a 3 stage heat pump
system.
2H 2C = 2 heat, 2 cool
3H 2C = 3 heat, 2 cool
This feature is shown only if the
HEAT PUMP technician setup
step is ON.
Use the
turn on of off.
or
key to
Use the or
key to
OFF
2H2C
change between 2 or 3
stages of heat. 2 heat will
use Y1 as first stage and W2
as auxiliary.
3 heat will use Y1 as the first
stage, Y2 as the second stage
and W2 as the auxiliary.
If ON is selected the humidity
will be displayed on the main
screen and HUM terminal
will energize when humidity
setpoint is above ambient
humidity in Heat mode.
Stages of
Heat
2
Humidify
STAGES
See terminal options on following
page.
OFF
OFF
STAGE
HUMIDITY
Requires Outdoor Sensor
This feature removes humidity
when SYSTEM key is in cool.
Use the
turn on of off.
or key to
OFF
An outdoor temperature
Use the
YES or NO.
or
to select
YES
If ON is selected the humidity
will be displayed on the main
screen and DHM terminal
will energize when humidity
setpoint is below ambient
humidity in Cool mode.
50
Balance Point
Temp
ABOVE this setting will LOCKOUT
the auxilary heat terminal (W2),
and ONLY ALLOW the heat pump/
compressor terminals (Y’s) to
energize.
Dehumidify
See terminal options on following
page.
If set to YES then use or
to select Balance point
Only shows if Heat
Pump is turned
ON and Remote
Sensor is set to 2.
DEHUMIDIFY
BALANCE Temperature of 10, 20, 30,
35, 40, 45 or 50 degrees.
An outdoor temperature
BELOW this setting can perform
2 different ways, depending on
the previous Gas Aux/Dual
Fuel setting.
This feature allows the installer
to change the calibration of the
ambient humidity displayed.
Use the
adjust the calibration +/-3.
or
key to
POINT
0
Humidity
Calibration
Requires
Outdoor Sensor
0
NO
3
1= approx. 5%
HUM
CALIBRATE
1. If Gas Aux/Dual Fuel is set OFF
(Default-typical Electric Aux
setting) This will allow both heat
pump (Y’s) and auxiliary heat
(W2) to run together.
This feature forces the A/C to run
longer to remove humidity when
needed. The A/C will “over cool”
the room a few degrees until the
humidity reaches the desired
setpoint.
Use the or
select YES or NO.
key to
Dehumidify
with AC
If selected Yes, allows over
cooling to be used to control
humidity in cool mode. If NO
is slected the system will not
use over cooling.
d HUMIDIFY
AC
2. If Gas Aux/Dual Fuel is set ON
(typical Gas Auxilary/Dual Fuel
setting) This will LOCKOUT the
heat pump (Y’s) and ONLY ALLOW
the auxiliary heat (W2) to energize
NO
NO
The amount of over cooling
allowed when using A/C to
remove humidity. This screen is
only shown when ON is selected
in the “Dehumidify with AC”tech
setup step.
Use the or key to
select the maximum number
of degrees of over cool.
3
Over Cool
Limit
Options are: 2, 3, 4, 5 Degrees.
OVER COOL
LIMIT
Balance point run time will allow
the W2 auxiliary terminal to
energize even if outdoor
temperature is above the selected
balance point temperature.
If enabled, auxiliary will energize
for the current cycle after the
balance point run time has
expired.
YES
15, 30, 45, 60, 75, 90
continuous run time
minutes.
Options for how the HUM
terminal energizes.
Use the or key to
select the one of the four
options.
1
Balance
Point Run
Time
HUM
Terminal
1
View the HUM terminal chart
below for an explanation of
these options.
BALANCE
RUNTIME
HUM
TERMINAL
26
25
| General | Details |
|---|---|
| Name | VIVE TP-S-955WH Programmable Thermostat Instruction Manual |
| Make | Vive |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.67 MB |