Vaillant VRC 700 Weather Compensating Thermostat Instruction Manual
3.7 Handing over to the end user
3.9 Resetting to factory setting
▶ Inform the end user of how to handle
and operate their product.
▶ Provide the end user with all relevant
instructions and unit documentation for
safe-keeping.
▶ Go through the operating instructions
with the end user.
▶ Answer any questions the end user may
have.
▶ In particular, draw the end user's at-
tention to the safety warnings that they
must follow.
▶ Inform the end user that room air must
be able to circulate freely around the
product, and that it should not be
covered by furniture, curtains or other
objects.
You can use this function to reset all the
set values that you configured using the
remote control installation assistant.
You can access the Reset to default
setting? function directly by activat-
ing the remote control using the rotary
knob or one of the selection buttons and
then pressing and holding both selection
buttons at the same time for at least 10
seconds.
3.10 Operating and display
functions
The remote control has an end user level
and an installer level.
The setting and read-out options for the
competent person can be found via the
selection button Menu → Installer level →
Enter code.
▶ Inform the end user that all the radiator
valves in the room where the product is
installed must be fully open.
If you do not know the code, you can clear
the code using the Default setting func-
tion. All the set values will be lost if you do
this.
3.8 Operation
You can only operate the remote control
unit in combination with the VRC 700 sys-
tem control. This means that it is also ne-
cessary to read through the operating in-
structions for the VRC 700 system control.
The operating instructions for the system
control will provide you with
The path details given at the start of each
function description indicate how you
reach this function in the menu structure.
– Information on the operating structure.
– Information on the operating concept
with examples.
3.10.1 Reading the fault status
Menu → Installer level → System config-
– A detailed description of the operating
and display functions that the remote
control unit also has.
uration [System ----] → Fault status
– This function allows you to read the
status of the heating installation. If there
is no fault present, the No fault mes-
sage appears. If a there is a fault, then
Fault list appears as a status. If you
press the right-hand selection button,
displayed.
3.10.2 Reading the software version
Menu → Installer level → System config-
uration [System ----] → Control modules
10
Operating and installation instructions 0020200905_02
– You can use this function to read the
software versions of the remote control
unit.
3.13 Recycling and disposal
Packaging
▶ Dispose of the packaging correctly.
3.10.3 Setting the address for the
remote control unit
This product is an electrical or electronic
unit within the context of EU Directive
2012/19/EU. The unit was developed and
manufactured using high-quality materials
and components. These can be recycled
and reused.
Menu → Installer level → System config-
uration [System ----] → Remote control
address
– You can use this function to set the ad-
Find out about the regulations that apply in
your country regarding the separate collec-
tion of waste electrical or electronic equip-
ment. Correctly disposing of old units pro-
tects the environment and people against
potential negative effects.
dress for the remote control unit.
Every remote control unit has a unique ad-
dress, starting with Address 1. Increase
the number in the address consecutively
for each additional remote control unit
used.
▶ Dispose of the packaging correctly.
3.11 Troubleshooting
3.11.1 Fault messages
▶ Observe all relevant regulations.
Disposing of the product
If a fault occurs in the heating installation,
will appear in the display together with
a fault message.
If the product is labelled with this
symbol:
Troubleshooting faults (→ Appendix B.3)
Troubleshooting errors (→ Appendix B.4)
▶ In this case, do not dispose of the
product with the household waste.
▶ Instead, hand in the product to a collec-
tion centre for waste electrical or elec-
tronic equipment.
3.12 Decommissioning
3.12.1 Decommissioning the heating
installation
Disposing of batteries
▶ Decommission all system components
of the heating installation, as described
in the installation instructions for the
individual system components.
If the product contains batteries that
are labelled with this symbol:
▶ In this case, dispose of the batteries at
a collection point for batteries.
◁ Prerequisite: The batteries can be
removed from the product without
causing any destruction. Otherwise,
the batteries are disposed of to-
gether with the product.
▶ In accordance with the legal regula-
tions, the end user is obligated to re-
turn used batteries.
3.12.2 Removing the product from
the wall
1. Insert the screwdriver into the slot on
the wall base.
2. Lever the product off the wall base.
3. Disconnect the eBUS line from the pin
header on the product and from the
terminal block on the heat generator.
4. Unscrew the wall-mounting base from
the wall.
Deleting personal data
Personal data may be misused by unau-
thorised third parties.
0020200905_02 Operating and installation instructions
11
| General | Details |
|---|---|
| Name | Vaillant VRC 700 Weather Compensating Thermostat Instruction Manual |
| Make | Vaillant |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.24 MB |

Vaillant VRT15 Room Thermostat User Guide

Vaillant VRC 700 Programmable Weather Compensating Thermostat Owner’s Manual

vaillant VR 92f/3 Wireless Additional Room Thermostat Instructions

Vaillant VRT 51f sensoROOM Wireless Room Thermostat Instruction Manual

Vaillant senso Comfort Thermostat Instructions