SIEMENS 194-2042 Pnuematic Room Thermostat User Guide
192 SSingle Setpoint
192 DN/ DNV Day/ Night/ Vent
Pneumatic Room Thermostats
Pneumatic Room Thermostats
Features
Features
•
•
•
Single setpoint dial available in Fa.hrenheit or Celsius scales.
Direct or reverse acting models
•
•
•
Dual setpoint dials available in Fahrenheit or Celsius scales.
Direct or reverse acting models.
Sensitive bimetallic element
responds to temperature
Sensitive bimetallic element
responds to temperature
changes.
changes.
•
•
Integral, adjustable limit stops.
•
•
Manual override selector for off-
hour occupant comfort.
Wall mounting plate included for
easy connection to rough-in
boxes.
Adjustable changeover pressure.
Applications
Applications
The 192 DN/ DNV Pneumatic Room
Designed for heating and cooling
Thermostat controls valves and
applications for control of pneumatic valves and damper actuators, the
192 SSingle Setpoint Pneumatic Room Thermostat is excellent for
commercial and institutional facilities.
damper actuators in cooling equipment, automatically performing
setback changes from day to night. The 192 DNV also performs a purge
sequence at night to bring in “vent” outside air to cool the building. A
manual override selector switch allows individual room or zone “day”
control locally during the night cycle. During the night control cycle, the
192 DNV models provide a separate output signal (full air supply)
allowing ventilation control. Periodic resetting to the “night” control
mode during evening or weekend periods using time clocks ensures
optimal energy management.
These are available with both 1-pipe and 2-pipe configurations.
1-pipe: Use when limited output air capacity is required to operate a
single valve and/or actuator; requires external restrictor, 20 scim (5.4
ml/ s) air supply.
2-pipe: Use for high output capacity for control of multiple valves and
actuators, used with or without high/low limiting controls.
Click on this link for 192 DN/ DNV Technical Instructions
Click on this link for 192 STechnical Instructions
192 HC Heating/ Cooling
193 HC Free Energy Band Heating/ Cooling
Pneumatic Room Thermostats
Pneumatic Room Thermostat
Features
Features
•
•
•
Dual setpoint dials available in Fahrenheit or Celsius scales.
Direct or reverse acting models.
•
•
•
Dual setpoint dials available in Fahrenheit or Celsius scales.
Integral, adjustable limit stops.
Sensitive bimetallic element
responds to temperature
Sensitive bimetallic element
responds to temperature
changes.
changes.
•
•
•
Integral, adjustable limit stops.
Adjustable changeover pressure.
Large volume air capacity rela.y
•
•
Adjustable Free Energy Band.
Wall mounting plate included for
easy connection to rough-in
boxes.
Applications
Designed for temperature control of
Applications
heating and cooling applications, the
Designed for buildings with early morning heat requirements and mid-
morning to afternoon cooling requirements, the 193 HCFree Energy
Band Pneumatic Room Thermostat two temperature thermostat
controls valves, damper actuators and mechanical heating and cooling
equipment. Providing energy management and occupant comfort, the
thermostat automatically reduces heating load and increases cooling
load.
192 HCHeating/Cooling Pneumatic Room Thermostat controls valves
and damper actuators in cooling equipment. Providing energy
management and occupant comfort, the thermostat automatically
adjusts to seasonal changes from heating setpoint to cooling setpoint in
commercial and institutional facilities. It is available in a 2-pipe
configuration.
2-pipe (dual 1-pipe): Use when a limited air capacity is required to
operate a single valve and/or actuator.
Click on this link for 192 HCTechnical Instructions
3-pipe (dual 2-pipe): Use for multiple valves and actuators with or
without high/ low limiting controls which require higher air capacities.
Click on this link for 193 HCTechnical Instructions
Page 2
Siemens Industry, Inc.
| General | Details |
|---|---|
| Name | SIEMENS 194-2042 Pnuematic Room Thermostat User Guide |
| Make | SIEMENS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.12 MB |

SIEMENS RDZ100ZB Zigbee Room Thermostat Owner’s Manual

SIEMENS RDG400 Room Thermostat Instruction Manual

SIEMENS M3182 Room Thermostat Instruction Manual

SIEMENS RDS120-B Smart Thermostat Instructions

SIEMENS Powers Controls TH 192-3 Series Day Night Vent Room Thermostat Instruction Manual

SIEMENS RDY2000BN BACnet Commercial Thermostat User Manual

SIEMENS RDH100RF/SET Room Thermostat Instruction Manual

SIEMENS RDH100RF/SET Wireless Room Thermostat with LCD User Guide

SIEMENS RS485 Flush Mounted Room Thermostat User Manual

SIEMENS RDG260KN Room Thermostat Instruction Manual