Satel ART-210 Wireless Radiator Thermostat Instruction Manual
4
ART-210
SATEL
trouble with changing the valve position. Make sure the thermostat is mounted
correctly on the valve and check the valve operation or restart the thermostat
(remove the batteries and insert them again).
incorrect operating range of the thermostat (calibration failure). Make sure the
thermostat is mounted correctly on the valve or restart the thermostat (remove the
batteries and insert them again).
valve control disabled to protect against complete battery discharge (battery voltage
dropped below 2.2 V). Replace the batteries.
problem with the knob.
motor error.
internal error.
unable to fully close the valve (calibration failure). Make sure the thermostat is
mounted correctly on the valve or restart the thermostat (remove the batteries and
insert them again).
The events labelled as
ABAX 2 system as no communication with the thermostat.
,
,
,
,
,
and
will be indicated in the
Units
temperature is displayed in degrees Celsius.
valve position is displayed in percent (0P – valve fully closed; 100P – valve fully open).
Knob
Press (Fig. 2) – turn on the display / change the operating mode / confirm new temperature
settings or valve position.
Press and hold for 3 seconds – block the knob / unblock the knob / edit temperature for the
selected operating mode / stop the Boost Heat.
Turn right – temperature up / open the valve.
Turn left – temperature down / close the valve.
Press and turn right – start the Boost Heat function.
Press and turn left – fully close the valve.