Satel ART-210 Wireless Radiator Thermostat Instruction Manual
SATEL
ART-210
5
Radio communication
The thermostat connects to the controller at regular time intervals to provide information
about its state (periodical communication). Additional communication takes place when the
ART-210 thermostat is sending to the controller the settings adjusted manually.
Energy saving mode (ECO)
If you want to prolong the battery life, you can enable the ECO option in the device. When the
ECO option is enabled, the periodical communication takes place every 3 minutes. This can
significantly increase the battery life.
Battery status control
The thermostat is monitoring the battery voltage. When the battery voltage is lower than
2.3 V, i.e. the batteries are low:
• the
message is shown after turning on the display,
• each radio transmission contains information about low battery.
When the battery voltage drops below 2.2 V, the thermostat will disable the valve control in
order to protect the battery from complete discharge. The
the valve will be set in the 25% open position.
message will be displayed and
Operating modes
Comfort temperature – thermostat is to maintain room temperature at a comfortable level.
This mode can be enabled remotely or manually.
Economy temperature – thermostat is to maintain temperature at an energy-efficient level
(e.g. when household members are at work or asleep at night). This mode can be enabled
remotely or manually.
Manual – thermostat is to maintain the set temperature / radiator valve is to be set in a given
position. This mode can be enabled remotely or manually but the temperature / valve
position can only be set manually.
The Manual operating mode can be enabled remotely if the controller is connected to
a SATEL alarm control panel. If the operating mode was enabled remotely,
the thermostat can only be controlled manually. Remote control is possible only after
the mode is disabled remotely.
Thermostat calibration
When calibrating, the thermostat adjusts its actuator stroke to the radiator valve stroke.
During calibration, the thermostat operating range is defined (the valve end positions, where:
0% = valve fully closed, 100% = valve fully open). The thermostat must be calibrated after it
is mounted on the valve and each time after batteries are replaced. The
be shown on the LED display when calibration is required.
message will
Thermostat adaptation
After it is started, the thermostat will analyze which valve position is optimal to heat the room
to set temperature. If the valve is not open enough, heating up the room takes too long. If the
valve is open too much, the room heats up fast but the temperature continues to rise beyond
the set value and the room becomes too hot. This is repeated whenever the thermostat
detects that the conditions in the room have changed in a way that can affect its operation.
During adaptation, whenever the knob is pressed, the
alternately with the temperature registered by the sensor.
message will be displayed