SALUS Thermostat RT520 User Manual
2.5 Connection description
I A - Boiler connection
RT520
RT520
NC
COM
NO
3V
2 x AA
3V
2 x AA
A
B
(ON / OFF)
OpenTherm
I B - Pump / Valve connection
AC 230V
L
RT520
NC
COM
NO
3V
2 x AA
lub
MAX
3 (1) A
N
I C - KL08NSB underfloor heating wiring center connection
Eg.
RT520
Eg.
RT520
Eg.
RT520
COM NO
COM NO
COM NO
KL08NSB
L
N
SL
L
N
SL
L
N
SL
or
lub
1 - 8 Zones
1 - 8 Zones
1 - 8 Zones
Power
Pump
Boiler
BOILER CONNECTION*
L
N
L
N
L
N
L
N
1
2
3
4
max 6
per zone
max 6
per zone
max 6
per zone
T30NC
T30NC
T30NC
AC 230V
L
N
Legend:
Symbols explanation:
Boiler - Boiler connection*
- Boiler’s contacts for ON/OFF
thermostat (according to the
boiler’s instructions)
L, N - power supply 230V
NO, COM, NC - voltage-free output
A, B - OpenTherm Communication Wire
SL - 230V AC voltage output
- NSB function
Pump
Valve
M
- fuse
8
| General | Details |
|---|---|
| Name | SALUS Thermostat RT520 User Manual |
| Make | SALUS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 1.76 MB |

SALUS IT800 WIFI Smart Thermostat Installation Guide

SALUS 091FLRF Wireless Room Thermostat User Guide

SALUS Thermostat Sensor TS600 User Guide

SALUS Thermostat and Smart Plug Installation Guide

SALUS Wired Digital Thermostat – Non-programmable HTRS230 User Manual

SALUS RT520 Radiator Thermostat User Guide

SALUS Programmable Wired Thermostat VS30W/VS30B Installation Guide

SALUS Wired Thermostat Installation Guide

SALUS RT310 Thermostat User Manual

SALUS BTR230 Room Thermostat User Guide